H. Martinez, Manuel d'implantologie clinique, 2e édition. Rueil-Malmaison, Cdp, pp.2-584, 2008.

M. Davarpanah, Période antique à nos jours Disponible sur http, 2012.

P. Leclercq, S. L. Dohan, and D. M. Dohan, Implantologie axiale : procédures chirurgicales et stratégies prothétiques, EMC -Médecine buccale, vol.2008, pp.1-29

D. Weng, M. Nagata, M. Bell, A. F. Bosco, L. De-melo et al., Influence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogs, Clinical Oral Implants Research, vol.15, issue.(Suppl.), pp.1141-1147, 2008.
DOI : 10.1902/jop.1997.68.11.1117

L. Rose, B. Mealey, and R. Genco, Periodontics: medicine, surgery and implants

L. Théry, La connexion implantaire interne ou externe? L'information dentaire, pp.1467-1470, 2006.

R. Pessoa, L. Muraru, E. Junior, L. Vaz, J. Sloten et al., Influence of Implant Connection Type on the Biomechanical Environment of Immediately Placed Implants - CT-Based Nonlinear, Three-Dimensional Finite Element Analysis, Clinical Implant Dentistry and Related Research, vol.13, issue.9, pp.219-234, 2010.
DOI : 10.1111/j.1600-0501.2000.tb00012.x

M. Bateli, W. Att, and J. R. Strub, Implant Neck Configurations for Preservation of Marginal Bone Level: A Systematic Review, International Journal of Oral & Maxillofacial Implants, vol.26, issue.2, pp.209-300, 2011.

Y. Hirofumi, Three-dimensional finite element analysis http:// www.sweden-martina.com [en ligne, Dental Materials, vol.281010, issue.13, pp.1126-1133, 2012.

G. Zuck, Le choix des piliers implantaires, Le défit implantaire

M. Lamy, Prothèse implantaire fixe scellée et vissée à l'heure du numérique

O. Fromentin, Critères de choix des systèmes d'attachements en prothèse amovible complète supra-implantaire (PACSI) Réalites cliniques Szmukler-moncler S., Wiskott A., Crottaz C.; quintessence, Intérêt clinique des évolutions matérielles en implantologie 2009 ; [En ligne] sur http, pp.161-171, 2003.

A. Freitas, . Jr, E. Bonfante, E. Rocha, N. Silva et al., Effect of implant connection and restoration design (screwed vs. cemented) in reliability and failure modes of anterior crowns, European Journal of Oral Sciences, vol.2, issue.4, pp.323-330, 2011.
DOI : 10.3109/00016357709064128

G. Grégoire, M. A. Bayle, and J. J. Guyonnet, Evaluation de la biocompatibilité des dispositifs médicaux utilisés en odontologie : Moyens et protocole d'expérimentation

F. F. Todescan, F. E. Pustiglioni, A. V. Imbronito, T. Albrektsson, and M. Gioso, Influence of the Microgap in the Peri-implant Hard and Soft Tissues: A Histomorphometric Study in Dogs, The International Journal of Oral & Maxillofacial Implants, vol.17, issue.4, pp.467-471, 2002.

B. Talwar, A Focus on Soft Tissue in Dental Implantology, The Journal of Indian Prosthodontic Society, vol.12, issue.3, pp.137-142, 2012.
DOI : 10.1007/s13191-012-0133-x

M. Postaire and M. Daas, Edentement complet mandibulaire et prothèse amovible implanto-retenue. L'information dentaire, pp.85-87, 2011.

B. Cannas, L. Gillot, and R. Noharet, Evolution du macro-design de l'implant vis

J. Mallet and . Dentisterie-restauratrice, Cours de parodontologie D2, Faculté d'odontologie Paris VII, 2010 ; p.155 ; disponible en ligne sur : http://www.garanciere.fr, pp.5-135, 2010.

B. Jakubowicz-kohen, T. Rouach, and C. Rignon-bret, Esthétique et préservation tissulaire péri-implantaire. L'information dentaire, pp.1268-1272, 2008.

T. O. Närhi, Structure of peri-implant gingival tissues In: Tissue engineering and regenerative medicine, pp.190-192, 2013.

C. Malevez, Clinical and radiographic evaluation of the papilla level adjacent to single tooth dental-implant. A retrospective study in the maxillary anterior region, Journal of Periodontology, vol.72, issue.10, pp.1363-1371, 2001.

S. Wallace, Significance of the biologic width, with respect to root-form implants, Dental implantology update, vol.5, pp.25-29, 1994.

J. Hermann, D. Cochran, P. Nummikoski, and D. Buser, Crestal Bone Changes Around Titanium Implants. A Radiographic Evaluation of Unloaded Nonsubmerged and Submerged Implants in the Canine Mandible, Journal of Periodontology, vol.11, issue.11, pp.1117-1130, 1997.
DOI : 10.1016/0030-4220(59)90078-7

L. Persson, U. Lekholm, A. Leonhardt, G. Dahlen, and J. Lindhe, Bacterial colonization on internal surfaces of Branemark systemR implant components, Clinical Oral Implants Research, vol.7, issue.2, pp.90-95, 1996.
DOI : 10.1034/j.1600-0501.1996.070201.x

I. Ericsson, K. Nilner, B. Klinge, and P. Glantz, Radiographical and histological characteristics of ssubmerged and nonsubmerged titanium implants. An experimental study in the Labrador dog., Clinical Oral Implants Research, vol.7, issue.1, pp.20-26, 1996.
DOI : 10.1034/j.1600-0501.1996.070103.x

M. Nevins, D. Kim, S. Jun, K. Guze, P. Schupbach et al., Histologic évidence of a connective tissue attachment to laser microgrooved abutments: a canine study, The International Journal of Periodontics & Restorative Dentistry, vol.30, issue.3, pp.245-254, 2010.

R. R. Barros, N. A. Jr, V. A. Muglia, G. Iezzi, and A. Piatelli, Influence of interimplant distances and placement depth on peri-implant bone remodeling of adjacent and immediately loaded Morse cone connection implants: a histomorphometric study in dogs, Clinical Oral Implants Research, vol.19, issue.4, pp.371-378, 2010.
DOI : 10.1097/01.ID.0000075720.78252.54

L. Bakaeen, P. Quinian, J. Schoolfield, N. Lang, and D. Cochran, The Biologic Width Around Titanium Implants: Histometric Analysis of the Implantogingival Junction Around Immediately and Early Loaded Implants, The International Journal of Periodontics & Restorative Dentistry, vol.29, issue.3, pp.297-305, 2009.

M. R. Norton, Multiple Single-Tooth Implant Restorations in the Posterior

D. Cochran, Peri-implant inflammation defined by the implant-abutment interface

C. Chu, J. Hsu, L. Fuh, and H. Huang, Biomechanical Evaluation of Subcrestal Placement of Dental Implants: In Vitro and Numerical Analyses, Journal of Periodontology, vol.24, issue.1, pp.302-310, 2011.
DOI : 10.1067/mpr.2001.115251

F. Hermann, H. Lerner, and A. Palti, Factors Influencing the Preservation of the Periimplant Marginal Bone, Implant Dentistry, vol.16, issue.2, pp.165-175, 2007.
DOI : 10.1097/ID.0b013e318065aa81

J. Torres, M. Mechali, O. Romieu, and F. Cuisinier, Mise au point d???un mod??le de diffusion gazeuse pour l?????valuation de l?????tanch??it?? des connexions implantaires, 56??me Congr??s de la SFMBCB, p.137, 2011.
DOI : 10.1051/sfmbcb/20115602008

URL : http://www.sfco-congres.org/10.1051/sfmbcb/20115602008/pdf

C. Silva, G. De-almeida-soares, G. Vidigal, and . Jr, Evaluation of Implant-Abutment Microgap and Bacterial Leakage in Five External-Hex Implant Systems: An In Vitro Study, International journal of oral and maxillofacial implants, vol.27, issue.2, pp.346-351, 2012.

J. Hermann, J. Schoolfield, R. Schenk, D. Buser, and D. Cochran, Influence of the size of the microgap on the crestal bone changes round titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible

T. Miyata, Y. Kobayashi, H. Araki, T. Ohto, and K. Shin, The influence of controlled occlusal overloard on peri-implant tissue. A histologic study in monkeys, International journal of oral and maxillofacial implants, vol.15, issue.3, pp.425-431, 2000.

T. Tsuge, Y. Hagiwara, and H. Matsumura, Marginal Fit and Microgaps of Implant-abutment Interface with Internal Anti-rotation Configuration, Dental Materials Journal, vol.27, issue.1, pp.29-34, 2008.
DOI : 10.4012/dmj.27.29

G. E. Romanos, Implants with progressive threads and conical implantabutment connections, Eastman Dental center, Rochester university, Division of normal dentistry and Periodontology, NY Tapered screw-vent implant sytem Disponible sur http, 2009.

S. Baixe, G. Fauxpoint, Y. Arntz, and E. O. , Microgap between zirconia abutments and titanium implants, International journal of oral and maxillofacial implants, vol.25, pp.455-460, 2010.
URL : https://hal.archives-ouvertes.fr/hal-00658914

P. Narang, H. Gupta, A. Arora, and A. Bhandari, Biomechanics of implant abutment connection: A review, Indian Journal of Stomatology, vol.2, issue.2, pp.113-116, 2011.

T. Lee, J. Han, J. Yang, J. Lee, and S. Kim, The assessment of abutment screw stability between the external and internal hexagonal joint under 138

S. Harder, B. Dimaczek, Y. Açil, H. Terheyden, S. Freitag-wolf et al., Molecular leakage at implant-abutment connection, vitro investigations of tightness of internal conical implant-abutment connections against endotoxin penetration

B. Assenza, D. Tripodi, A. Scarano, V. Perrotti, A. Piatetelli et al., Bacterial Leakage in Implants With Different Implant???Abutment Connections: An In Vitro Study, Journal of Periodontology, vol.25, issue.4, pp.491-497, 2012.
DOI : 10.1111/j.1600-051X.2010.01674.x

M. E. Jaworski, M. Melo, A. C. , T. Picheth, C. De et al., Analysis of the Bacterial Seal at the Implant-Abutment Interface in External-Hexagon and Morse Taper?Connection Implants: An In Vitro Study Using a New Methodology

W. Teixeira, R. F. Ribeiro, S. Sato, and V. Pedrazzi, Microleakage into and from Two-Stage Implants: An in vitro Comparative study, The International Journal of Oral & Maxillofacial Implants, vol.26, issue.1, pp.56-62, 2011.

M. Tesmer, S. Wallet, T. Koutouzis, and T. Lundgren, Bacterial Colonization of the Dental Implant Fixture???Abutment Interface: An In Vitro Study, Journal of Periodontology, vol.15, issue.12, pp.1991-1997, 2009.
DOI : 10.1902/jop.2008.070132

S. Dibart, M. Warbington, M. Su, and Z. Skobe, In vitro evaluation of the implantabutment bacterial seal: the locking taper system, International Journal of Oral and Maxillofacial Implants, vol.20, pp.732-737, 2005.

T. Koutouzis, S. Wallet, N. Calderon, and T. Lundgren, Bacterial Colonization of the Implant???Abutment Interface Using an In Vitro Dynamic Loading Model, Journal of Periodontology, vol.38, issue.1, pp.613-618, 2011.
DOI : 10.1902/jop.2008.070132

R. Faria, G. May, L. , D. Vasconcellos, D. Volapto et al., Evaluation of the bacterial leakage along the implant-abutment interface, Journal of Dental Implants, vol.1, issue.2, pp.51-57, 2011.
DOI : 10.4103/0974-6781.91280

V. Jansen, G. Conrads, and E. Richter, Microbial leakage and marginal fit of the implant?abutment interface, International Journal of Oral and Maxillofacial Implants, vol.12, pp.527-567, 1997.

L. Steinebrunner, S. Wolfart, K. Bössmann, and M. Kern, In Vitro Evaluation of Bacterial Leakage Along the Implant-Abutment Interface of Different Implant SystemsThe, International Journal of Oral & Maxillofacial Implants, vol.20, pp.875-881, 2005.

H. P. Flach and M. , Non linear 3d evaluation of different oral implant abutment connection, Journal of Dental Research, vol.91, issue.12, pp.1184-1189, 2012.

U. M. Wikesjö and I. Rhyu, The Effect of internal versus external abutment connection modes on crestal bone changes around dental implants: a radiographic analysis, Journal of periodontology, vol.83, pp.1104-1109, 2012.

C. Chu, H. Huang, J. Hsu, and L. Fuh, Influences of Internal Tapered Abutment Designs on Bone Stresses Around a Dental Implant: Three-Dimensional Finite Element Method With Statistical Evaluation, Journal of Periodontology, vol.43, issue.1, pp.111-118, 2012.
DOI : 10.1016/j.jbiomech.2009.10.030

A. Veis, N. Parissis, A. Tsirlis, C. Papadeli, G. Marinis et al., Evaluation of Peri-Implant Marginal Bone Loss Using Modified Abutment Connections at Various Crestal Level Placements, The International Journal of Periodontics & Restorative Dentistry, vol.30, issue.6, pp.609-616, 2010.

D. Weng, H. Nagata, M. J. Leite, C. Nascimento-de-melo, L. Bosco et al., Influence of Microgap Location and Configuration on Radiographic Bone Loss in Nonsubmerged Implants: An Experimental Study in Dogs, The International Journal of Prosthodontics, vol.24, issue.5, pp.445-450, 2011.

D. Weng, H. Nagata, M. J. Bell, M. Nascimento-de-melo, L. Bosco et al., Influence of Microgap Location and Configuration on Peri-implant Bone Morphology in Nonsubmerged Implants: An Experimental Study in Dogs, The International Journal of Oral & Maxillofacial Implants, vol.25, issue.3, pp.540-546, 2010.

F. Schwartz, M. Herten, K. Bieling, and J. Becker, Crestal bone changes at nonsubmerged implants (camlog) with different machined collar lengths: a histomorphometric pilot study in dogs, The International Journal of Oral & Maxillofacial Implants, vol.23, issue.2, pp.335-342, 2008.

M. Paolantonio, G. Perinetti, S. D-'ercole, F. Graziani, G. Catamo et al., Internal Decontamination of Dental Implants: An In Vivo Randomized Microbiologic 6-Month Trial on the Effects of a Chlorhexidine Gel, Journal of Periodontology, vol.22, issue.3
DOI : 10.1034/j.1600-0501.1994.050205.x

L. Rimondini, C. Marin, F. Brunella, and M. Fini, Internal contamination of a 2- component implant system after occlusal loading and previsionally luted reconstruction with or without a washer device, Journal of Periodontology, vol.7212, issue.79, pp.1652-1657, 2001.

U. Salihoglu, D. Boynuegri, D. Engin, A. Duman, P. Gokalp et al., Bacterial adhesion and colonization differences between zirconium oxide and titanium alloys: an in vivo human study, The International Journal of Oral & Maxillofacial Implants, vol.26, issue.1, pp.101-107, 2011.

A. Al-radha, D. Dymock, C. Younes, and D. O-'sullivan, Surface properties of titanium and zirconia dental implant materials and their effect on bacterial adhesion, Journal of Dentistry, vol.40, issue.2
DOI : 10.1016/j.jdent.2011.12.006

B. Assenza, D. Triopodi, A. Scarano, V. Perrotti, A. Piattelli et al., Bacterial Leakage in Implants With Different Implant???Abutment Connections: An In Vitro Study, Journal of Periodontology, vol.25, issue.4, pp.491-497, 2012.
DOI : 10.1111/j.1600-051X.2010.01674.x

A. Piattelli, screw-vs cement-implant-retained restorations: an experimentae study in the beagle. Part 1. Screw and abutment loosening, Journal of Oral Implantology, vol.35, issue.5, pp.242-246, 2005.

D. Sohn, M. Bae, J. Heo, J. Park, S. Yea et al., Retrospective multicenter analysis of immediate provisionalization using one piece implant narrow diameter (3mm) implants, The International Journal of Oral & Maxillofacial Implants, vol.26, issue.1, pp.163-168, 2011.

C. Soardi, A. Bianchi, E. Zandanel, and S. Spinato, Clinical and radiographic evaluation of immediately loaded one-piece implants placed into fresh extraction sockets, Quintessence international, vol.43, issue.3, pp.449-456, 2012.

M. Jaworski, M. Melo, A. , T. Picheth, C. De et al., Analysis of the Bacterial Seal at the Implant-Abutment Interface in External-Hexagon and Morse Taper Connection Implants: An In Vitro Study Using a New Methodology

B. Saluja and D. Mittal, One piece implant. A return to simplicity, Guident, 2012.

K. Finne, E. Rompen, and J. Toljanic, Three-Year Prospective Multicenter Study Evaluating Marginal Bone Levels and Soft Tissue Health Around a One-Piece Implant System, The International Journal of Oral & Maxillofacial Implants, vol.27, issue.2, pp.458-465, 2012.

P. Ostman, M. Hellman, T. Albrektsson, and L. Sennerby, Direct loading of Nobel Direct and Nobel Perfect one-piece implants: a 1-year prospective clinical and radiographic study. Clincal Oral implants research, pp.409-418, 2007.

S. Kim, K. Oh, D. Han, S. Heo, I. Ryu et al., Influence of Transmucosal Designs of Three One-Piece Implant Systems on Early Tissue Responses: A Histometric Study in Beagle Dogs, The International Journal of Oral & Maxillofacial Implants, vol.25, issue.1, pp.309-314, 2010.

M. Lopez-mari, Implant platform switching concept: An updated review, Medicina Oral Patologia Oral Cirugia Bucal, vol.14, issue.9, pp.450-454, 2009.

K. Prasad, M. Shetty, N. Bansal, and C. Hegde, Connection Plate-forme switching : Une réponse à la perte de la crête osseuse, Journal of dental implants, vol.1, issue.1, pp.13-17, 2011.

T. Balwar, A Focus on Soft Tissue in Dental Implantology, Journal of Indian Prosthodontics Society, vol.12, issue.3, pp.137-142, 2012.

R. Cocchetto, T. Traini, F. Caddeo, and R. Celletti, Evaluation of Hard Tissue Response Around Wider Platform?Switched, ImplantsThe International Journal of Periodontics & Restorative Dentistry, vol.30, issue.2, pp.163-171, 2010.

A. Veis, N. Parissis, A. Tsirlis, C. Papadeli, G. Marinis et al., Evaluation of Peri-Implant Marginal Bone Loss Using Modified Abutment Connections at Various Crestal Level Placements, The International Journal of Periodontics & Restorative Dentistry, vol.30, issue.6, pp.609-617, 2010.

F. Siffert and O. Et-etienne, Le concept du platform swiching : analyse de la littérature, Quintessence international, vol.8, issue.4, pp.260-268, 2011.

J. Giovannoli, Etages transmuquex et santé peri-implantaire, Titane, 2011.

M. A. Atieh, H. Ibrahim, and A. Atieh, Platform Switching for Marginal Bone Preservation Around Dental Implants: A Systematic Review and Meta-Analysis, Journal of Periodontology, vol.53, issue.1
DOI : 10.1016/S0895-4356(00)00242-0

S. Fickl, O. Zuhr, J. Stein, and M. Hürzeler, Peri-Implant Bone Level Around Implants with Platform-Switched Abutments, The International Journal of Oral & Maxillofacial Implants, issue.3, pp.25-577, 2010.

S. Vandeweghe and H. Et-de-bruyn, A within-implant comparison to evaluate the concept of platform switching. A randomized controlled trial, European Journal of Oral Implantology, vol.5, issue.3, pp.253-262, 2012.

L. Canullo, J. Rosa, V. Pinto, C. Francischone, and W. Götz, Inward-Inclined Implant Platform for the Amplified Platform-Switching Concept: 18-Month Follow-up Report of a Prospective Randomized Matched-Pair Controlled Trial, The International Journal of Oral & Maxillofacial Implants, vol.27, issue.4, pp.927-933, 2012.

S. Kano, P. Binon, G. Bonfante, and D. Curtis, Effect of Casting Procedures on Screw Loosening in UCLA-Type Abutments, Journal of Prosthodontics, vol.4, issue.2, pp.77-81, 2006.
DOI : 10.1067/mpr.2001.114266

S. Kano, P. Binon, G. Bonfante, and D. Curtis, The effect of casting procedures on rotational misfit in castable abutments, The International Journal of Oral & Maxillofacial Implants, vol.22, issue.4, pp.575-579, 2007.

S. Kano, P. Binon, and D. Curtis, A Classification System to Measure the Implant-Abutment Microgap, The International Journal of Oral & Maxillofacial Implants, vol.22, issue.6, pp.879-885, 2007.

R. Junior, Use of checkerboard DNA?DNA hybridization to evaluate the internal contamination of dental implants and comparison of bacterial leakage with cast or pre-machined abutments, Clinical Oral Implant Research, vol.20, pp.571-577, 2009.

M. Altmann, J. Cognet, L. Eschbach, B. Gasser, G. Richards et al., Matériaux utilisés pour l'osteosynthese. EMC, Techniques-chirurgicales-Orthopédietraumatologie, pp.44-0151, 2007.

R. Stüker, E. Teixeira, J. Beck, and N. Da-costa, Preload and torque removal evaluation of three different abutment screws for single standing implant restorations, Journal of Applied Oral Science, vol.88, issue.2
DOI : 10.1067/mpr.2002.127604

C. Mangano, F. Mangano, A. Piattelli, G. Iezzi, A. Mangano et al., Prospective Clinical Evaluation of 307 Single-Tooth Morse Taper?Connection Implants: A Multicenter Study, The International Journal of Oral & Maxillofacial Implants, vol.25, issue.2, pp.394-400, 2010.

P. Coelho, P. Sudack, M. Suzuki, K. Kurtz, G. Romanos et al., evaluation of the implant abutment connection sealing capability of different implant systems, Journal of Oral Rehabilitation, vol.12, issue.12, pp.917-924, 2008.
DOI : 10.1902/jop.1996.67.10.986

L. Panza, N. Boscatto, and A. A. Cury, Evaluation of pre-tightening in abutments and prosthetic screws on different implant connections, Revista Odonto Ci??ncia (Online), vol.25, issue.3, pp.292-295, 2010.
DOI : 10.1590/S1980-65232010000300014

B. Dailey, L. Jordan, O. Blind, and B. Tavernier, Axial Displacement of Abutments into Implants and Implant Replicas, with the Tapered Cone-Screw Internal Connection, as a Function of Tightening Torque, The International Journal of Oral & Maxillofacial Implants, vol.24, issue.2, pp.251-255, 2009.

A. Piattelli, screw-vs cement-implant-retained restorations: an experimentae study in the beagee.part 1: screw and abutment loosening, Journal of Oral Implantology, vol.31, issue.5, pp.242-246, 2005.

D. Bozkaya and S. Müftü, Mechanics of the tapered interference fit in dental implants, Journal of Biomechanics, vol.36, issue.11, pp.1649-1658, 2003.
DOI : 10.1016/S0021-9290(03)00177-5

R. A. Coppete, M. Chiarello-de-mattos, S. Rodriguez, R. C. Ribeiro, and R. , Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study, Clinical of Oral Implant Research, vol.20, pp.624-632, 2009.

K. Kim, Y. Lim, M. Kim, H. Kwon, J. Yang et al., Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection, Clinical Oral Implants Research, vol.64, issue.8
DOI : 10.1016/0022-3913(90)90177-E

L. Steinebrunner, S. Wolfart, K. Ludwig, and M. Kern, Implant-abutment interface design affects fatigue and fracture strength of implants, Clinical Oral Implants Research, vol.20, issue.12, pp.1276-1284, 2008.
DOI : 10.1111/j.1600-0501.2008.01581.x

C. Ribeiro, M. Maia, S. Scherrer, A. Cardoso, and W. Hwa, Resistance of three implant-abutment interfaces to fatigue testing, Journal of Applied Oral Science, vol.14, issue.4, pp.413-420, 2010.
DOI : 10.1097/01.id.0000187902.68436.e4

J. Pedroza, Y. Torrealba, A. Elias, and W. Psoter, Comparison of the Compressive Strength of 3 Different Implant Design Systems, Journal of Oral Implantology, vol.33, issue.1, pp.1-7, 2007.
DOI : 10.1563/0-809.1

A. Coppede, E. Bernasi, M. Chiarello-de-mattos, S. Rodriguez, R. C. De et al., Fracture Resistance of the Implant-Abutment Connection in Implants with Internal Hex and Internal Conical Connections Under Oblique Compressive Loading: An In Vitro Study, International Journal of Prosthodontontics, vol.22, issue.3, pp.283-296, 2009.

Y. Seetoh, K. Tan, E. Chua, H. Quek, and J. Nicholls, Load Fatigue Performance of Conical Implant-Abutment Connections, The International Journal of Oral & Maxillofacial Implants, vol.26, pp.797-806, 2011.

S. Dittmer, M. Dittmer, P. Kohorst, M. Jendras, L. Brochers et al., Effect of Implant-Abutment Connection Design on Load Bearing Capacity and Failure Mode of Implants, Journal of Prosthodontics, vol.15, issue.Suppl 1, pp.510-516, 2011.
DOI : 10.1016/S0022-3913(99)70208-8

B. Kim, I. Yeo, J. Lee, S. Kim, S. Heo et al., The Effect of Screw Length on Fracture Load and Abutment Strain in Dental Implants with External

O. Hanisch, Piliers implantaires : critères de choix en vue de restaurations antérieures d´apparence naturelle. Stratégie prothétique, pp.247-261, 2003.

M. Nevins, M. Camelo, M. Nevins, P. Schupbach, and D. Kim, Pilot Clinical and Histologic Evaluations of a Two-Piece Zirconia Implant, The International Journal of Periodontics & Restorative Dentistry, vol.31, issue.2, pp.157-163, 2011.

E. Bressan, G. Paniz, D. Lops, B. Corazza, E. Romeo et al., Influence of abutment material on the gingival color of implant-supported all-ceramic restorations: a prospective multicenter study, Clinical Oral Implants Research, vol.20, issue.6, pp.631-637, 2011.
DOI : 10.1111/j.1600-0501.2009.01717.x

P. Viogolo, F. Fonzi, Z. Majzoub, and G. Cordioli, Evaluation of Gold-Machined UCLA-type Abutments and CAD/CAM Titanium Abutments with Hexagonal External Connection and with Internal Connection, The International Journal of Oral & Maxillofacial Implants, vol.23, pp.247-252, 2008.

O. Etienne and S. Baixe, Les piliers implantaires en zircone. Stratégie prothétique, pp.1-14, 2009.

B. Yüzügüllü and M. Avci, The Implant-Abutment Interface of Alumina and Zirconia Abutments, Clinical Implant Dentistry and Related Research, vol.2, pp.113-121, 2008.

N. Clelland, J. Seidt, L. Daroz, and E. Mcglumphy, Comparison of Strains for Splinted and Nonsplinted Implant Prostheses Using Three-Dimensional Image Correlation, The International Journal of Oral & Maxillofacial Implants, vol.25, issue.5, pp.953-959, 2010.

B. Rousselet, Le remplacement des dents de petit diamètre dans les zones esthétiques. Une nouvelle alternative l'implant Axiom de diamètre 2, pp.109-117, 2011.