B. 1. Rivers, E. Nguyen, B. Havstad, S. Ressler, J. Muzzin et al., Early Goal-Directed Therapy in the Treatment of Severe Sepsis and Septic Shock, New England Journal of Medicine, vol.345, issue.19, pp.3451368-1377, 2001.
DOI : 10.1056/NEJMoa010307

F. Aisous, M. Khamiees, A. Degirolamo, Y. Amoateng-adjepong, and C. Manthous, Negative fluid balance predicts survival in patients with septic shock: a retrospective pilot study, pp.1749-1754, 2000.

J. Foland, J. Fortenberry, B. Warshaw, R. Pettignano, R. Merritt et al., Fluid overload before continuous hemofiltration and survival in critically iII children: a retrospective analysis, Crit Care Med, issue.8, pp.321771-1776, 2004.

M. Cannesson, Y. Attol, P. Rosamel, D. 0. Joseph, and P. , Respiratory Variations in Pulse Oximetry Plethysmographic Waveform Amplitude to Predict Fluid Responsiveness in the Operating Room, Anesthesiology, vol.106, issue.6, pp.1105-1111, 2007.
DOI : 10.1097/01.anes.0000267593.72744.20

M. Cannesson, . Desebbe-0, P. Rosamel, B. Delannoy, R. J. Bastien-0 et al., Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre, British Journal of Anaesthesia, vol.101, issue.2, pp.200-206, 2008.
DOI : 10.1093/bja/aen133

M. Feissel, J. Teboul, P. Merlani, J. Badie, J. Falier et al., Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patients, Intensive Care Medicine, vol.33, issue.6, pp.993-999, 2007.
DOI : 10.1148/radiology.148.3.6878708

F. Michard and J. Teboul, Predicting Fluid Responsiveness in ICU Patients, Chest, vol.121, issue.6, pp.2000-2008, 2002.
DOI : 10.1378/chest.121.6.2000

J. Vincent and M. Weil, Fluid challenge revisited, Critical Care Medicine, vol.34, issue.5, pp.1333-1337, 2006.
DOI : 10.1097/01.CCM.0000214677.76535.A5

H. Wiedemann, A. Wheeler, G. Bernard, B. Thompson, D. Hayden et al., Comparison of two f1uid-management strategies in acute lung injury, N Engl J Med, issue.24, pp.3542564-2575, 2006.

D. Payen, A. De-pont, Y. Sakr, C. Spies, K. Reinhart et al., A positive fluid balance is associated with a worse outcome in patients with acute renal failure, R74. 11. Frank 0: Zur Dynamik des Herzmuskels. Z Bi%gie 1885, pp.370-447, 2008.
DOI : 10.1186/cc6916

E. Starling and M. Visscher, The regulation of the energy output of the heart, The Journal of Physiology, vol.62, issue.3, pp.243-261
DOI : 10.1113/jphysiol.1927.sp002355

X. Monnet and J. Teboul, Volume responsiveness, Current Opinion in Critical Care, vol.13, issue.5, pp.549-553, 2007.
DOI : 10.1097/MCC.0b013e3282ec68b2

D. Osman, C. Ridel, P. Ray, X. Monnet, N. Anguel et al., Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Cril Care Med, pp.64-68, 2007.

J. Teboul, Recommandations d'experts de la SRLFIndicateurs du remplissage vasculaire au cours de l'insuffisance circulatoire, pp.255-263, 2004.

M. Feissel, M. Slama, V. Baron, A. Vignon, P. Cholley et al., Remplissage vasculaire, pp.61-75
DOI : 10.1016/B978-2-84299-931-5.50005-4

K. Bendjelid and J. Romand, Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care, Intensive Care Medicine, vol.88, issue.3, pp.352-360, 2003.
DOI : 10.1093/bja/88.1.124

G. Bernardin and M. Mazerolles, Les crit??res h??modynamiques statiques pr??dictifs de l'efficacit?? d'un remplissage vasculaire, R??animation, vol.13, issue.4, pp.289-298, 2004.
DOI : 10.1016/j.reaurg.2004.03.007

B. Tavernier, . Makhotine-0, G. Lebuffe, J. Dupont, and P. Scherpereel, Systolic Pressure Variation as a Guide to Fluid Therapy in Patients with Sepsis-induced Hypotension, Anesthesiology, vol.89, issue.6, pp.1313-1321, 1998.
DOI : 10.1097/00000542-199812000-00007

C. Tousignant, F. Walsh, and C. Mazer, The use of transesophageal echocardiography for preload assessment in critically iII patients, Anesth Analg, vol.90, issue.2, pp.351-355, 2000.

M. Feissel, F. Michard, R. 0. Mangin-l, J. Falier, and J. Teboul, Respiratory Changes in Aortic Blood Velocity as an Indicator of Fluid Responsiveness in Ventilated Patients With Septic Shock, Chest, vol.119, issue.3, pp.867-873, 2001.
DOI : 10.1378/chest.119.3.867

B. Lamia, A. Ochagavia, X. Monnet, D. Chemla, C. Richard et al., Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity, Intensive Care Medicine, vol.32, issue.7, pp.1125-1132, 2007.
DOI : 10.1007/s00134-006-0274-7

O. Wahr, Y. Wang, and N. Schiller, Left ventricular volumes determined by two-dimensional echocardiography in a normal adult population, Journal of the American College of Cardiology, vol.1, issue.3, pp.863-868, 1983.
DOI : 10.1016/S0735-1097(83)80200-9

A. Coudray, J. Romand, M. Treggiari, and K. Bendjelid, Fluid responsiveness in spontaneously breathing patients: a review of indexes used in intensive care. Cril Care Med, pp.2757-2762, 2005.

P. Squara, D. Journois, P. Estagnasie, M. Wysocki, A. Brusset et al., Elastic Energy as an Index of Right Ventricular Filling, Chest, vol.111, issue.2, pp.351-358, 1997.
DOI : 10.1378/chest.111.2.351

D. Mangano, Monitoring pulmonary arterial pressure in coronary-artery disease. Anesthesia, pp.364-370, 1980.

A. Perel, R. Pizov, and S. Cotev, Systolic Blood Pressure Variation is a Sensitive Indicator of Hypovolemia in Ventilated Dogs Subjected to Graded Hemorrhage, Anesthesiology, vol.67, issue.4, pp.498-502, 1987.
DOI : 10.1097/00000542-198710000-00009

S. Magder, More respect for the CVP, Intensive Care Medicine, vol.349, issue.7, pp.651-653, 1998.
DOI : 10.1016/S0140-6736(96)05109-4

J. Calvin, A. Oriedger, and W. Sibbald, The hemodynamic effect of rapid fluid infusion in critically iII patients, Surgery, vol.90, issue.1, pp.61-76, 1981.

A. Schneider, G. Teule, A. Groeneveld, J. Nauta, G. Heidendal et al., Biventricular performance during volume loading in patients with early septic shock, with emphasis on the right ventricle: A combined hemodynamic and radionuclide study, American Heart Journal, vol.116, issue.1, pp.103-112, 1988.
DOI : 10.1016/0002-8703(88)90256-6

C. Reuse, J. Vincent, and M. Pinsky, Measurements of Right Ventricular Volumes during Fluid Challenge, Chest, vol.98, issue.6, pp.1450-1454, 1990.
DOI : 10.1378/chest.98.6.1450

J. Wagner and J. Leatherman, Right Ventricular End-Diastolic Volume as a Predictor of the Hemodynamic Response to a Fluid Challenge, Chest, vol.113, issue.4, pp.1048-1054, 1998.
DOI : 10.1378/chest.113.4.1048

V. Baron, A. Teboul, and J. , Evaluation de la réponse au remplissage vasculaire In: Les techniques de monitorage hémodynamique en réanimation, pp.167-181

S. Heenen, D. Backer, D. Vincent, and J. , How can the response to volume expansion in patients with spontaneous respiratory movements be predicted? Crit Care, p.102, 2006.

S. Soubrier, F. Saulnier, H. Hubert, P. Delour, H. Lenci et al., Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically iII patients? Intensive Care Med, pp.331117-1124, 2007.

D. Backer, D. Teboul, and J. , Le cath??ter art??riel pulmonaire, pp.39-51
DOI : 10.1007/978-2-287-71154-1_3

F. Michard, S. Boussat, D. Chemla, N. Anguel, A. Mercat et al., Relation between Respiratory Changes in Arterial Pulse Pressure and Fluid Responsiveness in Septic Patients with Acute Circulatory Failure, American Journal of Respiratory and Critical Care Medicine, vol.117, issue.1, pp.134-138, 2000.
DOI : 10.1016/0883-9441(92)90032-3

J. Teboul, M. Pinsky, A. Mercat, N. Anguel, G. Bernardin et al., Estimating cardiac tilling pressure in mechanically ventilated patients with hyperinflation, Crit Care Med, issue.11, pp.283631-3636, 2000.

R. Teplick, Measuring Central Vascular Pressures, Anesthesiology, vol.67, issue.3, pp.289-291, 1987.
DOI : 10.1097/00000542-198709000-00001

F. Michard and J. Teboul, Using heart-Iung interactions to assess fluid responsiveness during mechanical ventilation. Ctit Care, pp.282-289, 2000.

F. Michard and J. Teboul, La thermodilution transpulmonaire, pp.53-64
DOI : 10.1007/978-2-287-71154-1_4

E. Newman, M. Merrell, A. Genecin, C. Monge, W. Milnor et al., The Dye Dilution Method for Describing the Central Circulation: An Analysis of Factors Shaping the Time-Concentration Curves, Circulation, vol.4, issue.5, pp.735-746, 1951.
DOI : 10.1161/01.CIR.4.5.735

S. Sakka, C. Ruhl, U. Pfeiffer, R. Beale, A. Mcluckie et al., Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution, Intensive Care Medicine, vol.26, issue.2, pp.180-187, 2000.
DOI : 10.1007/s001340050043

F. Michard, S. Alaya, V. Zarka, M. Bahloul, C. Richard et al., Global End-Diastolic Volume as an Indicator of Cardiac Preload in Patients With Septic Shock *, Chest, vol.124, issue.5, pp.1900-1908, 2003.
DOI : 10.1378/chest.124.5.1900

C. Hofer, L. Furrer, S. Matter-ensner, M. Maloigne, R. Klaghofer et al., Volumetrie preload measurement by thermodilution: a comparison with transoesophageal echocardiography, Br J Anaesth, issue.6, pp.94748-755, 2005.

J. Renner, P. Meybohm, M. Gruenewald, M. Steinfath, J. Scholz et al., Global End-Diastolic Volume During Different Loading Conditions in a Pediatric Animal Model, Anesthesia & Analgesia, vol.105, issue.5, pp.1243-1249, 2007.
DOI : 10.1213/01.ane.0000281152.72734.d0

S. Preisman, U. Pfeiffer, N. Lieberman, and A. Perel, New monitors of intravascular volume: a comparison of arterial pressure waveform analysis and the intrathoracic blood volume, Intensive Care Medicine, vol.23, issue.6, pp.651-657, 1997.
DOI : 10.1007/s001340050389

D. Reuter, T. Felbinger, K. Moerstedt, F. Weis, C. Schmidt et al., Intrathoracic blood volume index measured by thermodilution for preload monitoring after cardiac surgery, Journal of Cardiothoracic and Vascular Anesthesia, vol.16, issue.2, pp.191-195, 2002.
DOI : 10.1053/jcan.2002.31064

C. Wiesenack, C. Prasser, C. Keyl, and G. Rodig, Assessment of intrathoracic blood volume as an indicator of cardiac preload: Single transpulmonary thermodilution technique versus assessment of pressure preload parameters derived from a pulmonary artery catheter, Journal of Cardiothoracic and Vascular Anesthesia, vol.15, issue.5, pp.584-588, 2001.
DOI : 10.1053/jcan.2001.26536

B. Morgan, W. Martin, T. Hornbein, E. Crawford, and W. Guntheroth, Hemodynamic Effects of Intermittent Positive Pressure Respiration, Anesthesiology, vol.27, issue.5, pp.584-590, 1966.
DOI : 10.1097/00000542-196609000-00009

R. Massumi, D. Mason, Z. Vera, R. Zelis, J. Otero et al., Reversed Pulsus Paradoxus, New England Journal of Medicine, vol.289, issue.24, pp.1272-1275, 1973.
DOI : 10.1056/NEJM197312132892403

A. Vieillard-baron, K. Chergui, A. Rabiller, . Peyrouset-0, B. Page et al., Superior vena cavai collapsibility as a gauge of volume status in ventilated septic patients, Intensive Care Med, vol.30, issue.9, pp.1734-1739, 2004.

M. Slama, H. Masson, J. Teboul, M. Arnout, D. Susic et al., Respiratory variations of aortic VTI: a new index of hypovolemia and fluid responsiveness, American Journal of Physiology-Heart and Circulatory Physiology, vol.90, issue.4, pp.1729-1733, 2002.
DOI : 10.1097/00000542-199409000-00012

F. Jardin, J. Farcot, P. Gueret, J. Prost, Y. Ozier et al., Cyclic changes in arterial pulse during respiratory support, Circulation, vol.68, issue.2, pp.266-274, 1983.
DOI : 10.1161/01.CIR.68.2.266

F. Saulnier, Indices dynamiques invasifs pr??dictifs de la r??ponse au remplissage vasculaire, R??animation, vol.13, issue.4, pp.299-305, 2004.
DOI : 10.1016/j.reaurg.2004.03.012

M. Feissel and A. Vieillard-baron, Evaluation de la volémie par échocardiographie à l'aide des interactions cardio-pulmonaires. Réanimation, pp.145-152, 2003.

S. Johnson and S. Henderson, Myth: The Trendelenburg position improves circulation in cases of shock, CJEM, vol.13, issue.01, pp.48-49, 2004.
DOI : 10.1097/00003246-197905000-00002

T. Boulain, J. Achard, J. Teboul, C. Richard, D. Perrotin et al., Changes in BP Induced by Passive Leg Raising Predict Response to Fluid Loading in Critically Ill Patients, Chest, vol.121, issue.4, pp.1245-1252, 2002.
DOI : 10.1378/chest.121.4.1245

X. Monnet and J. Teboul, Passive leg raising, Intensive Care Medicine, vol.33, issue.4, pp.659-663, 2008.
DOI : 10.1164/ajrccm.162.1.9903035

M. Antonelli, M. Levy, P. Andrews, J. Chastre, L. Hudson et al., Hemodynamic monitoring in shock and implications for management, International Consensus Conference, pp.27-28575, 2006.
DOI : 10.1177/088506669100600204

X. Monnet, M. Rienzo, D. Osman, N. Anguel, C. Richard et al., Passive leg raising predicts fluid responsiveness in the critically ill*, Critical Care Medicine, vol.34, issue.5, pp.1402-1407, 2006.
DOI : 10.1097/01.CCM.0000215453.11735.06

J. Teboul and X. Monnet, Pr??diction de la r??ponse ?? l???expansion vol??mique chez les patients en ventilation spontan??e, R??animation, vol.18, issue.3, pp.239-245, 2009.
DOI : 10.1016/j.reaurg.2009.02.008

D. Burkhoff, A. J. , J. Schipke, and J. , Assessment of Windkessel as a model of aortic input impedance, American Journal of Physiology-Heart and Circulatory Physiology, vol.255, issue.4, pp.742-753, 1988.
DOI : 10.1152/ajpheart.1988.255.4.H742

D. Chemla, J. Hebert, C. Coirault, K. Zamani, C. P. Suard-l et al., Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans, American Journal of Physiology-Heart and Circulatory Physiology, vol.261, issue.30, pp.500-505, 1998.
DOI : 10.1016/0002-8703(84)90555-6

J. Coyle, R. Teplick, M. Long, J. Davison, R. Pizov et al., Respiratory variations in systemic arterial pressure as an indicator of volume status. Anesthesia The effect of tldal volume and intravascular volume state on systolic pressure variation in ventilated dogs, Intensive Care Med, vol.59, issue.6, pp.15368-371, 1983.

G. Rooke, H. Schwid, and Y. Shapira, The effect of graded hemorrhage and intravascular volume replacement on systolic pressure variation in humans du ring mechanical and spontaneous ventilation, Anesth Analg, vol.80, issue.5, pp.925-932, 1995.

D. Reuter, T. Felbinger, E. Kilger, C. Schmidt, P. Lamm et al., Optimizing fluid therapy in mechanically ventilated patients after cardiac surgery by on???line monitoring of left ventricular stroke volume variations. Comparison with aortic systolic pressure variations, BJA: British Journal of Anaesthesia, vol.88, issue.1, pp.124-126, 2002.
DOI : 10.1093/bja/88.1.124

A. Denault, T. Gasior, J. Gorcsan, W. Mandarino, L. Deneault et al., Determinants of Aortic Pressure Variation During Positive-Pressure Ventilation in Man, Chest, vol.116, issue.1, pp.176-186, 1999.
DOI : 10.1378/chest.116.1.176

J. Robotham, D. Cherry, W. Mitzner, J. Rabson, W. Lixfeld et al., A re-evaluation of the hemodynamic consequences of intermittent positive pressure ventilation, Critical Care Medicine, vol.11, issue.10, pp.11783-793, 1983.
DOI : 10.1097/00003246-198310000-00005

F. Michard, D. Chemla, C. Richard, M. Wysocki, M. Pinsky et al., Clinical Use of Respiratory Changes in Arterial Pulse Pressure to Monitor the Hemodynamic Effects of PEEP, American Journal of Respiratory and Critical Care Medicine, vol.58, issue.3, pp.935-939, 1999.
DOI : 10.1001/jama.1996.03540110043030

D. Backer, D. Heenen, S. Piagnerelli, M. Koch, M. Vincent et al., Pulse pressure variations to predict fluid responsiveness: influence of tidal volume, Intensive Care Medicine, vol.108, issue.4, pp.517-523, 2005.
DOI : 10.1007/s00134-005-2586-4

S. Preisman, S. Kogan, H. Berkenstadt, and A. Perel, Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators ???, British Journal of Anaesthesia, vol.95, issue.6, pp.95746-755, 2005.
DOI : 10.1093/bja/aei262

. Goedje-0, K. Hoeke, M. Lichlwarck-aschoff, A. Faltchauser, P. Lamm et al., Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilution, Critical Care Medicine, vol.27, issue.11, pp.272407-2412, 1999.
DOI : 10.1097/00003246-199911000-00014

T. Onimus, F. Saulnier, S. Béague, P. Pronnier, S. Nseir et al., Comparaison de deux techniques de monitorage du d??bit cardiaque : m??thode du contour de pouls et thermodilution art??rielle pulmonaire continue, ITBM-RBM, vol.23, issue.4, pp.243-253, 2002.
DOI : 10.1016/S1297-9562(02)80030-4

D. Reuter, A. Kirchner, T. Felbinger, F. Weis, E. Kilger et al., Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function, Critical Care Medicine, vol.31, issue.5, pp.31-1399, 2003.
DOI : 10.1097/01.CCM.0000059442.37548.E1

C. Wiesenack, C. Prasser, G. Rodig, and C. Keyl, Stroke Volume Variation as an Indicator of Fluid Responsiveness Using Pulse Contour Analysis in Mechanically Ventilated Patients, Anesthesia & Analgesia, vol.96, issue.5, pp.1254-1257, 2003.
DOI : 10.1213/01.ANE.0000053237.29264.01

H. Berkensladt, N. Margalit, M. Hadani, Z. Friedman, E. Segal et al., Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery, Anesth Analg, vol.92, issue.4, pp.984-989, 2001.

G. Marx, T. Cope, L. Mccrossan, S. Swaraj, C. Cowan et al., Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis, European Journal of Anaesthesiology, vol.21, issue.2, pp.132-138, 2004.
DOI : 10.1097/00003643-200402000-00009

C. Hofer, S. Muller, L. Furrer, R. Klaghofer, M. Genoni et al., Stroke Volume and Pulse Pressure Variation for Prediction of Fluid Responsiveness in Patients Under oing Off-Pump Coronary Artery Bypass Grafting, Chest, vol.128, issue.2, pp.848-854, 2005.
DOI : 10.1378/chest.128.2.848

L. Huntsman, O. Stewart, S. Barnes, S. Franklin, J. Colocousis et al., Noninvasive Doppler determination of cardiac output in man. Clinical validation, Circulation, vol.67, issue.3, pp.593-602, 1983.
DOI : 10.1161/01.CIR.67.3.593

J. Maizel, N. Airapetian, E. Lorne, C. Tribouilloy, Z. Massy et al., Diagnosis of central hypovolemia by using passive leg raising, Intensive Care Medicine, vol.10, issue.7, pp.1133-1138, 2007.
DOI : 10.1016/S0735-1097(87)80275-9

M. Feissel, F. Michard, J. Falier, and J. Teboul, The respiratory variation in inferior vena cava diameter as a guide to fluid therapy, Intensive Care Medicine, vol.30, issue.9, pp.1834-1837, 2004.
DOI : 10.1007/s00134-004-2233-5

C. Barbier, Y. Loubieres, C. Schmil, J. Hayon, J. Ricome et al., Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients, Intensive Care Medicine, vol.30, issue.9, pp.1740-1746, 2004.
DOI : 10.1007/s00134-004-2259-8

S. Duperrel, F. Lhuillier, V. Piriou, E. Vivier, . Metton-0 et al., Increased intra-abdominal pressure affects respiratory variations in arterial pressure in normovolaemic and hypovolaemic mechanically ventilated healthy pigs, Intensive Care Medicine, vol.116, issue.1, pp.163-171, 2007.
DOI : 10.1007/s00134-003-1649-7

A. Vieillard-baron, R. Augarde, S. Prin, B. Page, A. Beauchet et al., Influence of superior vena cavai zone condition on cyclic changes in right ventricular outflow during respiratory support, Anesthesiology, issue.5, pp.951083-1088, 2001.

B. Cholley, A. Vieillard-baron, and A. Mebazaa, Echocardiography in the ICU: time for widespread use! Intensive Gare Med, pp.9-10, 2006.

C. Side and R. Gosling, Non-surgical Assessment of Cardiac Function, Nature, vol.232, issue.5309, pp.335-336, 1971.
DOI : 10.1038/232335a0

M. Slama, H. Masson, J. Teboul, M. Arnould, R. Nail-kaoudjl et al., Monitoring of respiratory variations of aortic blood flow velocity using esophageal Doppler, Intensive Care Medicine, vol.30, issue.6, pp.301182-1187, 2004.
DOI : 10.1007/s00134-004-2190-z

X. Monnel, M. Rienzo, D. Osman, N. Anguel, C. Richard et al., Esophageal Doppler monitoring predicts fluid responsiveness in critically iII ventilated patients, Intensive Gare Med, issue.9, pp.311195-1201, 2005.

J. Teboul and A. Vieillard-baron, Clinical value of pulse pressure variations in ARDS. Still an unresolved issue? Intensive Gare Med, pp.499-500, 2005.

J. Lefranl and D. Backer, Can we use pulse pressure variations to predict f1uid responsiveness in patients with ARDS? Intensive Gare Med, pp.966-968, 2009.

S. Tibby, M. Halherill, D. A. , and M. L. , Are transoesophageal Doppler parameters a reliable guide to paediatric haemodynamic status and fluid management? Intensive Gare Med, pp.201-205, 2001.

H. Tran, N. Froese, G. Dumonl, J. Lim, and J. Ansermino, Variation in Blood Pressure as a Guide to Volume Loading in Children Following Cardiopulmonary Bypass, Journal of Clinical Monitoring and Computing, vol.31, issue.5, pp.1-6, 2007.
DOI : 10.1007/BF00261495

P. Durand, L. Chevrel, S. Essouri, and V. Haas, Respiratory variations in aortic blood flow predict fluid responsiveness in ventilated children, Intensive Care Medicine, vol.168, issue.5, pp.888-894, 2008.
DOI : 10.1152/ajpheart.00308.2002

F. Michard, Changes in Arterial Pressure during Mechanical Ventilation, Anesthesiology, vol.103, issue.2, pp.419-428, 2005.
DOI : 10.1097/00000542-200508000-00026

H. Senzaki, M. Akagi, T. Hishi, A. Ishizawa, M. Yanagisawa et al., Age·associated changes in arterial elastic properties in children, Eur J Pediatr2002, issue.10, pp.161547-551

C. Papastamelos, H. Panitch, S. England, and J. Allen, Developmental changes in chest wall compliance in infancy and early childhood, Journal of Applied Physiology, vol.78, issue.1, pp.179-184, 1995.
DOI : 10.1152/jappl.1995.78.1.179

J. Renner, E. Cavus, P. Meybohm, M. Gruenewald, M. Steinfath et al., Pulse pressure variation and stroke volume variation during different loading conditions in a paediatric animal model, Acta Anaesthesiologica Scandinavica, vol.106, issue.(S, pp.374-380, 2008.
DOI : 10.1148/radiology.148.3.6878708

P. Marik, R. Cavai-lazzi, T. Vasu, and A. Hirani, Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature*, Critical Care Medicine, vol.37, issue.9, pp.2642-2647, 2009.
DOI : 10.1097/CCM.0b013e3181a590da

J. Severinghaus, The history of clinical oxygen monitoring, International Congress Series, vol.1242, pp.115-120, 2002.
DOI : 10.1016/S0531-5131(02)00723-9

J. Squire, Instrument for measuring quantity of blood and its degree of oxygenation in the web of the hand, Clin Sel, vol.4, pp.331-339, 1940.

G. Millikan, The Oximeter, an Instrument for Measuring Continuously the Oxygen Saturation of Arterial Blood in Man, Review of Scientific Instruments, vol.96, issue.10, pp.434-444, 1942.
DOI : 10.1097/00000658-194010000-00023

J. Severinghaus, Takuo Aoyagi: Discovery of Pulse Oximetry, Anesthesia & Analgesia, vol.105, issue.On Line Suppl., pp.1-4, 2007.
DOI : 10.1213/01.ane.0000269514.31660.09

M. Feissel, La pl??thysmographie de??l'oxym??tre de??pouls: un??ancien trac?? plein d'avenir? Principes et??applications cliniques, R??animation, vol.16, issue.2, pp.124-131, 2007.
DOI : 10.1016/j.reaurg.2007.02.010

M. Feissel, J. Badie, P. Merlani, J. Falier, and K. Bendjelid, Pre-ejection period variations predict the fluid responsiveness of septic ventilated patients, Critical Care Medicine, vol.33, issue.11, pp.2534-2539, 2005.
DOI : 10.1097/01.CCM.0000186415.43713.2F

M. Cannesson, . Desebbe-0, M. Hachemi, D. Jacques, . Bastien-0 et al., Respiratory variations in pulse oximeter waveform amplitude are influenced by venous return in mechanically ventilated patients under general anaesthesia, European Journal of Anaesthesiology, vol.24, issue.3
DOI : 10.1017/S026502150600161X

A. Lima, P. Beelen, and J. Bakker, Use of a peripheral perfusion index derived from the pulse oximetry signal as a noninvasive indicator of perfusion, Critical Care Medicine, vol.30, issue.6, pp.1210-1213, 2002.
DOI : 10.1097/00003246-200206000-00006

C. De-felice, G. Latini, P. Vacca, and R. Kopotic, The pulse oximeter perfusion index as a predictor for high illness severity in neonates, European Journal of Pediatrics, vol.91, issue.Suppl1, pp.561-562, 2002.
DOI : 10.1378/chest.94.2.227a

B. Partridge, Use of pulse oximetry as a non invasive indicator of intravascular volume status, J Clin Monil, vol.19873, issue.4, pp.263-268

M. Shamir, L. Eidelman, Y. Floman, L. Kaplan, and R. Pizov, Pulse oximetry plethysmographic waveform during changes in blood volume, British Journal of Anaesthesia, vol.82, issue.2, pp.178-181, 1999.
DOI : 10.1093/bja/82.2.178

J. Teboul and X. Monnet, Detecting volume responsiveness and unresponsiveness in intensive care unit patients: two different problems, only one solution, Critical Care, vol.13, issue.4, p.175, 2009.
DOI : 10.1186/cc7979

M. Feissel, G. Roblès, R. Falier, J. Teboul, and J. , Les variations respiratoires de la pléthysmographie de l'oxymètre de pouls sont-elles un nouvel indice prédictif de la réponse au remplissage vasculaire chez les patients ventilés? Réanimation, p.12274, 2003.

K. Bendjelid, The pulse oximetry plethysmographic curve revisited, Current Opinion in Critical Care, vol.14, issue.3, pp.348-353, 2008.
DOI : 10.1097/MCC.0b013e3282fb2dc9

M. Cannesson, B. Delannoy, A. Morand, P. Rosamel, and Y. Altol, Does the Pleth Variability Index Indicate the Respiratory-Induced Variation in the Plethysmogram and Arterial Pressure Waveforms?, Anesthesia & Analgesia, vol.106, issue.4, pp.1189-1194, 2008.
DOI : 10.1213/ane.0b013e318167ab1f

G. Natalini, A. Rosano, M. Franceschelti, P. Facchelti, and A. Bernardini, Variations in Arterial Blood Pressure and Photoplethysmography During Mechanical Ventilation, Anesthesia & Analgesia, vol.103, issue.5, pp.1182-1188, 2006.
DOI : 10.1213/01.ane.0000202380.22997.24

M. Cannesson, C. Besnard, P. Durand, J. Bohe, and D. Jacques, Relation between respiratory variations in pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure in ventilated patients, Critical Care, vol.9, issue.5, pp.562-568, 2005.
DOI : 10.1186/cc3799

H. Solus-biguenet, M. Fleylel, B. Tavernier, E. Kipnis, J. Onimus et al., Non-invasive prediction of fluid responsiveness during major hepatic surgery ??? ???, British Journal of Anaesthesia, vol.97, issue.6, pp.97808-816, 2006.
DOI : 10.1093/bja/ael250

G. Natalini, A. Rosano, M. Taranto, B. Faggian, E. Viltorielli et al., Arterial Versus Plethysmographic Dynamic Indices to Test Responsiveness for Testing Fluid Administration in Hypotensive Patients: A Clinical Trial, Anesthesia & Analgesia, vol.103, issue.6, pp.1478-1484, 2006.
DOI : 10.1213/01.ane.0000246811.88524.75

G. Keller, E. Cassar, . Desebbe-0, J. Lehot, and M. Cannesson, Ability of pleth variability index to detect hemodynamic changes induced by passive leg raising in spontaneously breathing volunteers. Cril Care, p.37, 2008.

A. Awad, A. Haddadin, H. Tantawy, T. Badr, R. Stout et al., The relationship between the photoplethysmographic waveform and systemic vascular resistance, Journal of Clinical Monitoring and Computing, vol.27, issue.6, pp.365-372, 2007.
DOI : 10.1016/S0140-6736(86)90837-8

K. Shelley, D. Jablonka, A. Awad, R. Stout, H. Rezkanna et al., What Is the Best Site for Measuring the Effect of Ventilation on the Pulse Oximeter Waveform?, Anesthesia & Analgesia, vol.103, issue.2, pp.372-377, 2006.
DOI : 10.1213/01.ane.0000222477.67637.17

J. Casado-flores, J. Barja, R. Martino, A. Serrano, and A. Valdivielso, Complications of central venous catheterization in critically ill children, Pediatric Critical Care Medicine, vol.2, issue.1, pp.57-62, 2001.
DOI : 10.1097/00130478-200101000-00012

M. Garcia-teresa, J. Casado-flores, D. Dominguez, M. Roqueta-mas, J. Cambra-lasaosa et al., Infectious complications of percutaneous central venous catheterization in pediatric patients, Intensive Care Medicine, vol.52, issue.5, pp.466-476, 2007.
DOI : 10.7326/0003-4819-136-11-200206040-00007

M. King, M. Garrison, M. Vavilala, J. Zimmerman, and F. Rivara, Complications associated with arterial catheterization in children. Pediatr Cril Care Med, pp.367-371, 2008.

M. Pollack, U. Ruttimann, and P. Getson, Pediatrie risk of mortality (PRI5M) score. en: Gare Med, pp.1110-1116, 1988.

P. Wyffels, P. Durnez, J. Helderweirt, W. , D. Kegel et al., Ventilation-Induced Plethysmographic Variations Predict Fluid Responsiveness in Ventilated Postoperative Cardiac Surgery Patients, Anesthesia & Analgesia, vol.105, issue.2, pp.448-452, 2007.
DOI : 10.1213/01.ane.0000267520.16003.17

M. Feissel, R. Kalakhy, J. Badie, G. Roblès, J. Falier et al., La variabilité respiratoire de la pléthysmographie issue de l'oxymétrie de pouls (PVI): un nouvel indice prédictif non invasif de la réponse au remplissage vasculaire, p.820, 2009.

B. Oubda, L. Tacon-8, M. M. Maurer, and P. , Monin P: Percutaneous oxygen saturometry measurement of perfusion index (PI) and its variability (PVI) as predictive factors of haemodynamic instability in paediatric critical care patients, Intensive Gare Medicine, issue.0, p.34876, 2008.