96 a) Pilier faux moignon, Piliers ZirDesign?, vol.97, issue.972, p.98 ,
115 III. Type de connexion à l'implant, p.117 ,
Periimplant hard and soft tissue integration to dental implants made of titanium and gold, Clinical Oral Implants Research, issue.18, pp.269-274, 2007. ,
Soft tissue response to plaque formation at different implant systems. A comparative study in the dog, Clinical Oral Implants Research, vol.9, issue.2, pp.73-79, 1998. ,
DOI : 10.1034/j.1600-0501.1998.090202.x
The mucosal barrier following abutment dis/reconnection. An experimental study in dogs, Journal of Clinical Periodontology, vol.13, issue.8, pp.568-572, 1997. ,
DOI : 10.1016/0142-9612(85)90104-8
The mucosal attachment at different abutments. An experimental study in dogs, Journal of Clinical Periodontology, vol.99, issue.9, pp.721-727, 1998. ,
DOI : 10.1023/A:1018579605426
The peri-implant hard and soft tissue charachteristics at differnet implant systems. A comparative study in dogs, Clin Oral Implant Res, issue.7, pp.212-219, 1996. ,
Le fraisage en prothèse implantaire. Stratégie prothétique, pp.291-305, 2006. ,
The long-terme efficacy of currently used dental implants: a review and proposed criteria of success, J Oral Maxillofac Implants, issue.1, pp.11-25, 1986. ,
Interface analysis of titanium and zirconium bone implants, Biomaterials, vol.6, issue.2, pp.97-101, 1985. ,
DOI : 10.1016/0142-9612(85)90070-5
Periodontal prosthesis. Twenty-five years in retrospect, Alpha Omegan, issue.67, pp.8-52, 1974. ,
Ceramic implant abutments for short-span FPDs: A prospective 5-year multicenter study, Int J Prosthodont, issue.16, pp.640-646, 2003. ,
Cemented single crowns on osseointegrated implants after 5 years: results from a prospective study on CeraOne, Int J Prosthodont, issue.11, pp.212-218, 1998. ,
Alumina ceramic implant abutments used for single-tooth replacement: a Prospective 1 to 3-year multicenter study, 2001. ,
Dimensional alterations of the gingiva related to changes of facial/lingual tooth position in permanent anterior teeth of children. A 2-year longitudinal study, Journal of Clinical Periodontology, vol.14, issue.3, pp.219-224, 1993. ,
DOI : 10.1016/0889-5406(87)90450-1
Comparative study of antirotational single tooth abutments, The Journal of Prosthetic Dentistry, vol.73, issue.1, pp.36-43, 1995. ,
DOI : 10.1016/S0022-3913(05)80270-7
L'indexation en prothèse implantaire. Stratégie prothétique, pp.237-242, 2009. ,
Dimension of the periimplant mucosa. Biologic width revisited, J Clin Periodontol, issue.23, pp.971-973, 1996. ,
The soft barrier at implants and teeth, Clinical Oral Implants research, issue.2, pp.81-90, 1991. ,
Soft tissue reaction to de novo plaque formation on implants and teeth. An experimental study in the dog, Clinical Oral Implants Research, vol.3, issue.1, pp.1-8, 1992. ,
DOI : 10.1034/j.1600-0501.1992.030101.x
Papilla regeneration by noninvasive prosthodontic treatment:segmental proximal restorations. Pract Periodontics Aesth Dent, pp.77-78, 1998. ,
Single implant restorations:prosthetically induced soft tissue topography, Pract Periodontics, Aesthet Dent, issue.9, pp.745-752, 1997. ,
An introduction to the design and behavior of bolted joints. (éd, 1995. ,
The role of screws in implant systems, Int J Oral Maxillofac Implants, pp.48-63, 1994. ,
Evaluation of maching accuracy and consistency of selected implants, standard abutments, and laboratory analogs, Int J Prosthodont, issue.8, pp.162-178, 1995. ,
Evaluation of three slip fit hexagonal implants, Implant Dent, vol.172, issue.5, pp.235-248, 1996. ,
Operator variability of tightening torque with the Astfa Implant system, Unpublished Data, 1998. ,
The External Hexagonal Interface and Screw-Joint Stability: A Primer on Threaded Fasteners in Implant Dentistry, Implant Dentistry, pp.91-103, 2000. ,
The effect of eliminating implant/abutment rotational misfit on screw joint stability, The International Journal of Prosthodontics, issue.9, pp.511-519, 1996. ,
The uncertainties of measuring fastener preload, Machine Design, issue.37, pp.128-131, 1965. ,
In Vivo Bone Response to Biomechanical Loading at the Bone/Dental-Implant Interface, Advances in Dental Research, vol.29, issue.225, pp.99-119, 1999. ,
DOI : 10.1007/BF00351420
Tightening charahcteristics for screwed joints in osseointegrated dental implants, The Journal of Prosthetic Dentistry, issue.71, pp.592-599, 1994. ,
Soft Tissue Reactions to Non-Submerged Unloaded Titanium Implants in Beagle Dogs, Journal of Periodontology, vol.34, issue.3, pp.225-235, 1992. ,
DOI : 10.1902/jop.1961.32.3.261
Survival rate, fracture strength and failure mode of ceramic implant abutments after chewing simulation, Journal of Oral Rehabilitation, vol.37, issue.11, pp.838-843, 2005. ,
DOI : 10.1046/j.1365-2842.1999.00416.x
Le risque esthétique chez l'édenté partiel en implantologie, J Parondontal Implant Oral, issue.17, pp.317-331, 1998. ,
Multidisciplinary implant dentistry for improved aesthetics and function, pp.177-86, 1998. ,
Examination of the implant???abutment interface after fatigue testing, The Journal of Prosthetic Dentistry, vol.85, issue.3, pp.268-275, 2001. ,
DOI : 10.1067/mpr.2001.114266
Biologic with around titanium implants. A histometric analysis of the implanto-Gingival junction around unloaded and loaded nonsubmerged impalnts in the canive mandible, J Periodontol, issue.68, pp.186-198, 1997. ,
Manuel d'implantologie clinique, 2ème édition. 92856 Rueil-Malmaison Cedex: collection JPIO, éditions CdP, 2008. ,
The concept of platform-switching and its applications, Implants, vol.3, issue.14, pp.185-198, 2008. ,
Comparaison of external and internal hex implant's rotational freedom: a pilot study, Int J Prosthodont, issue.18, pp.165-166, 2005. ,
A comparative study of the clinical efficacy of screw vent implants versus branemark fixtures, installed in a periodontal clinic, Clinical Oral Implants Research, issue.3, pp.32-41, 1992. ,
Effects of infection control procedures on the accuracy of a new mechanical torque wrench system for implant restorations, The Journal of Prosthetic Dentistry, vol.75, issue.1, pp.93-98, 1996. ,
DOI : 10.1016/S0022-3913(96)90424-2
Comparaison of screw loosening, rotation, and deflection among three implant designs, The Journal of Prosthetic Dentistry, issue.74, pp.270-278, 1995. ,
EXTERNALLY HEXED IMPLANTS, ABUTMENTS, AND TRANSFER DEVICES: A COMPREHENSIVE OVERVIEW, Implant Dentistry, vol.1, issue.4, pp.273-283, 1992. ,
DOI : 10.1097/00008505-199200140-00009
Radiographical and histological charachteristics of submerged and non-submerged titanium implants. An Experimental study in the Labrador dogs, Clin Oral Impalnts Res, issue.7, pp.20-26, 1996. ,
Different types of inflammatory reactions in periimplant soft tissues, J Clin Periodontol, issue.22, pp.255-261, 1995. ,
Les piliers implantaires en zircone. Stratégie prothétique février, pp.1-15, 2009. ,
A radiographic evaluation of bone healing around submerged and non-submerged dental implants ine beagle dogs, J Periodontol, issue.70, pp.248-254, 1999. ,
Dimensions and relations of the dento-gingival junction in humain, J Periodontol, issue.32, pp.261-267, 1961. ,
Choix du pilier en prothèse fixée implanto-portée, Parodont Dent Rest, vol.174, issue.19, pp.233-241, 1999. ,
Torque generated by handheld screwdrivers and mechanical torquing devices for osseo-integrated implants, Int J Oral Maxillofac Implants, issue.9, pp.149-155, 1994. ,
Clinical complications of osseointegrated implants. The journal of Prosthetic Dentistry, pp.537-552, 1999. ,
Micromotion and dynamic fatigue properties of the dental implant???abutment interface, The Journal of Prosthetic Dentistry, vol.85, issue.1, pp.47-52, 2001. ,
DOI : 10.1067/mpr.2001.112796
Principles of occlusion. Anaheim: The denar corporation, 1970. ,
Elongation and preload stress in dental implant abutments screws, Int J Oral Maxillofac Implants, issue.10, pp.529-536, 1995. ,
Elongation and preload stress in dental implant abutment screws, The International Journal of Maxillofacial Implants, issue.10, pp.529-536, 1995. ,
Septembre) Piliers implantaires: critères de choix en vue de restaurations antérieures d'apparence naturelle, Stratégie Prothétique, vol.3, issue.4, pp.247-262, 2003. ,
Biologic width around one-and two-piece titanium implants, Clin Oral Impalnts Res, issue.12, pp.559-571, 2001. ,
Personal Communication, 1995. ,
Microbial leakage and marginal fit of the implantabutment interface, Int J Oral Maxillofac Implants, issue.12, pp.527-540, 1997. ,
Failures and complications in 391 consecutively inserted fixed prostheses supported by branemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup, The International Journal of Oral & Maxillofacial Implant, issue.6, pp.270-276, 1991. ,
A 3-year follow-up study on single implant treatment, Journal of Dentistry, vol.21, issue.4, pp.203-208, 1993. ,
DOI : 10.1016/0300-5712(93)90127-C
The effect of allceramic and porcelain-fused-to-metal restorations on marginal peri-implant soft tissue color:a randomized controlled clinical trial, The International Journal of Periodontics & Restorative Dentistry, vol.28, issue.4, pp.357-365, 2008. ,
A 1-year radiographic evaluation of marginal bone around dental implants, Int J Oral Maxillofac Implants, issue.11, pp.811-818, 1996. ,
Fatigue resistance of two implant/abutment joint designs, The Journal of Prosthetic Dentistry, vol.88, issue.6, pp.604-610, 2002. ,
DOI : 10.1067/mpr.2002.129384
Fatigue resistance of two implant/abutment joint designs, The Journal of Prosthetic Dentistry, vol.88, issue.6, pp.604-610, 2002. ,
DOI : 10.1067/mpr.2002.129384
Influence of the Size of the Microgap on Crestal Bone Levels in Non-Submerged Dental Implants: A Radiographic Study in the Canine Mandible, Journal of Periodontology, vol.1, issue.10, pp.1111-1117, 2002. ,
DOI : 10.1111/j.1399-302X.1987.tb00298.x
A zirconia implantcrown system: a case report, International Journal of Periodontics and Restorative Dentistry, issue.17, pp.147-153, 2004. ,
Esthetics: The orthodonticperiodontic restorative connection, Semin Orthod, issue.2, pp.21-30, 1996. ,
Single-tooth replacement with the frialit-2 system: a retrospective clinical analysis of 146 implants, The International Journal of Oral and Maxillofac Implants, issue.17, pp.78-85, 2002. ,
The effect of the use of a counter-torque device on the abutment-implant complex, J Prosthet Dent, issue.81, pp.411-417, 1999. ,
Criteria for implant selection: surgical and prosthetic, Pract Periodont Aesteth Dent, issue.6, pp.55-62, 1994. ,
Platform-switching: un nouveau concept implantiare de contröle des niveaux osseux après mise en charge, Quintessence International, vol.26, issue.1, pp.9-17, 2006. ,
Principles for single tooth replacement The Bränemark osseointegrated implant, pp.117-143, 1989. ,
Periodontal tissues and their counterparts around endosseous implants, Clinical Oral Implants Research, vol.2, issue.3, pp.1-19, 1991. ,
DOI : 10.1034/j.1600-0501.1991.020309.x
Strenght and toughness of dental ceramics, Mörmann, CAD/Cim in Aesthetic Dentistry, pp.229-239, 1996. ,
Personal communications noted in: Tan KB. The clinical distortion in implant prosthodontics: Is there such a thing as passive fit, pp.138-157, 1995. ,
In vitro differences of stress concentrations for internal and external hex implant-abutment connections: a short communication, Journal of Oral Rehabilitation, vol.13, issue.1, pp.75-78, 2006. ,
DOI : 10.1067/mpr.2001.116230
Les implants: chirurgie et prothèse, Choix thérapeutique stratégique. 92856 Rueil-Malmaison Cedex: collection JPIO, éditions CdP, 2008. ,
Implant superstructures: a comparaison of ultimate failure force, The International Journal of Oral and Maxxillogacial Implants, issue.7, pp.35-39, 1992. ,
New cermaic core implant abutment: a comparison study, J Dent Res, issue.71, p.115, 1992. ,
Mechanics of the implant abutment connection: An 8-degree taper compared to a butt joint connection, Int J Oral Maxillofac Implants, issue.15, pp.519-526, 2000. ,
The influence of controlled occlusal overload on peri-implant tissue. Part 4. A histologic study in monkeys, Int J Oral Maxillofac Implants, issue.12, pp.384-390, 2002. ,
The position of the margin of the gingiva, Oral Surgery, Oral Medicine, Oral Pathology, vol.11, issue.9, pp.969-984, 1958. ,
DOI : 10.1016/0030-4220(58)90137-3
An in vitro evaluation of the strength of an internal conical interface compared to a butt joint interface in implant design, Clinical Oral Implants Research, vol.8, issue.4, pp.290-298, 1997. ,
DOI : 10.1034/j.1600-0501.1997.080407.x
Esthétique et implantologie: Gestion des tissus osseux et périimplantaires, 2001. ,
Esthetics and osseointegration, 1989. ,
Longitudinal radiographic study of crestal bone levels adajcent to non-submerged dental implants, J Oral Implantol, vol.177, issue.22, pp.26-34, 1994. ,
Dental implant design-effect on bone remodeling, Journal of Biomedical Materials Research, vol.67, issue.4, pp.467-483, 1991. ,
DOI : 10.1177/00220345800590022001
A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. I. Implant-supported FPDs, Clinical Oral Implants Research, vol.68, issue.3, pp.625-642, 2004. ,
DOI : 10.1034/j.1600-0501.1995.060207.x
Esthetic high strenght implant abutments. Part II, J Esthet Dent, issue.8, pp.255-262, 1993. ,
Esthetic High-Strength Implant Abutments. Part II, Journal of Esthetic and Restorative Dentistry, vol.9, issue.2, pp.29-36, 1993. ,
DOI : 10.1016/0022-3913(83)90174-9
Gestion esthetique d'un implant unitaire avec une greffe de tissu conjonctif enfouie: cas clinique avec trois ans de suivi, Parodont Dent Rest, pp.93-101, 1999. ,
Fixture design and overload influence marginal bone loss and fixture success in the Bränemark system, Clin Oral Implants Res, pp.104-111, 1992. ,
Load factor control for implants in the posterior partially edentulous segment, Int J Oral Maxilllofac Implants, pp.360-370, 1997. ,
Forces and moments on Bränemark implants, Int J Oral Maxillofac Implants, pp.241-247, 1989. ,
Bending overload and implant fracture: a retrospective clinical analysis, Int J Oral Maxillofac Implants, pp.326-334, 1995. ,
In vivo vertical forces on implants. The International Journal of Oral and Maxillogacial Implants, pp.99-108, 1995. ,
Soft tissue stability at the facial aspect of gingivally converging abutments in the esthetic zone: A pilot clinical study, The Journal of Prosthetic Dentistry, vol.97, issue.6, pp.97-119, 2007. ,
DOI : 10.1016/S0022-3913(07)60015-8
Selection and ideal tridimensional implant position for soft tissue aesthetics, Pract Periodont Aesth Dent, vol.178, issue.11, pp.1063-72, 1999. ,
In Vitro Study of the Influence of the Type of Connection on the Fracture Load of Zirconia Abutments with Internal and External Implant-Abutment Connections, The International Journal of Oral & Maxillofacial Implants, issue.24, pp.850-858, 2009. ,
Single-tooth implant reconstructions; esthetic factors influencing the decision between titanium and zirconia abutments in anterior regions, The European Journal of Esthetic Dentistery, vol.2, issue.3, 2007. ,
The interproximal height of bone: A guidepost to predictable aesthetic strategies and soft tissue contours in anterior tooth replacement, Pract Periodontics Aesthet Dent, issue.10, pp.1131-1141, 1998. ,
The reactions of bone, connective tissue, and epithelium to endosteal implants with titanium-sprayed surfaces, Journal of Maxillofacial Surgery, vol.9, issue.9, pp.15-25, 1981. ,
DOI : 10.1016/S0301-0503(81)80007-0
Effects of Repeated Manual Disassembly and Reassembly on the Positional Stability of Various Implant-Abutment Complexes:An Experimental Study, INT J ORAL MAXILLOFAC IMPLANTS, issue.25, pp.86-94, 2010. ,
Bone tissue responses to surfacemodified zirconia implants: a histomorphometric and removal torque study in the rabbit, Clinical Implant Dentistry and Related Research, issue.7, pp.13-20, 2005. ,
Mechanical engineering design The role of the implant housing in obtaining aesthetics: Generation of peri-implant gingivae and papillae.Part 1, Pract Proced Aesthet Dent, issue.15, pp.141-149, 1987. ,
The role of the implant housing in obtaining aesthetics: Part 2. Customizing the periimplant soft tissue, Pract Proced Aesthet Dent, issue.15, pp.487-490, 2003. ,
Implant_abutment interface design affects fatigue and fracturestrength of implants, Clin Oral Impl Res, pp.1276-1284, 2008. ,
Considerations of implant abutment and crown contour: critical contour and subcritical contour, International Journal of Periodontis and Restorative Dentistry, vol.30, issue.4, pp.334-343, 2010. ,
The reverse-torque test: a clinical report, Int J Oral Maxillofac Implants, vol.179, issue.11, pp.179-185, 1996. ,
Vertical Distance from the Crest of Bone to the Height of the Interproximal Papilla Between Adjacent Implants, Journal of Periodontology, vol.15, issue.12, pp.1785-1788, 2003. ,
DOI : 10.1034/j.1600-0501.2000.011001001.x
Structure of the interface between rabbit cortical bone and implants of gold, zirconium and titanium, Journal of Materials Science: Materials in Medicine, issue.8, pp.653-665, 1997. ,
Optimisation du profil d'émergence et intégration gingivale en prothèse implantaire, Inform Dentaire, issue.5, pp.297-308, 2000. ,
Comparaison de la stabilité en rotation de différents dispositifs antirotationnels, Implants, issue.4, pp.201-211, 1998. ,
An in vitro evaluation of titanium, zirconia and alumina procera abutments with hexagonal connection, Int J Oral Maxillofac Implants, issue.21, pp.575-580, 2006. ,
Studies on Humain Bite Force. A Novel Bite Force Recorder and its Clinical Applications, 1995. ,
A 5-year prospective clinical and radiographic study of non-submerged dental implants, Clinical Oral Implants Research, vol.11, issue.2, pp.144-153, 2000. ,
DOI : 10.1034/j.1600-0501.2000.110207.x
Biomechanics of force distribution in implant-supported prostheses, Int J Oral Maxillofac Implants, issue.8, pp.19-31, 1993. ,
Single-tooth anterior implant: A world of caution, J Esthet Dent, pp.225-233, 1997. ,
The mucosal barrier at implant abutments of different materials, Clin. Oral Impl. Res, pp.635-641, 2008. ,
Wheeler's atlas of tooth form, 1984. ,
The Implant-Abutment Interface of Alumina and Zirconia Abutments, Clinical Implant Dentistry and Related Research, vol.8, issue.2, pp.113-121, 2008. ,
DOI : 10.1016/S0022-3913(05)80134-9
Soft tissue reactions to plaque formation at implant abutments with different surface topography. An experimental study in dogs, Journal of Clinical Periodontology, vol.99, issue.5, pp.456-461, 2002. ,
DOI : 10.1111/j.1365-2818.1973.tb04629.x