I. Propriétés-du-titane and :. , 11 1. Les charges de surface pour une surface d'oxyde de titane hydratée, p.12

A. Le-sablage and :. , 28 B. Pulvérisation thermique par plasma, p.32

:. La-morphologie, 67 A. Straumann, p.69

A. Abron, M. Hopfensperger, J. Thompson, and L. Cooper, Evaluation of a predictive model for implant surface topography effects on early osseointegration in the rat tibia model, The Journal of Prosthetic Dentistry, vol.85, issue.1, pp.40-46, 2001.
DOI : 10.1067/mpr.2001.112415

C. Aparicio, F. J. Gil, and C. Fonseca, Corrosion behavior of commercially pure titanium shot blasted with different materials and size of shot particles for dental implant applications

B. Aronsson, J. Lausmaa, and B. Kasemo, Glow discharge plasma treatment for surface cleaning and modification of metallic biomaterials, Journal of Biomedical Materials Research, vol.11, issue.252
DOI : 10.1116/1.578718

P. J. Bania, Titanium Alloys in the 1990's, The Mineral, Metals & Materials Society, pp.3-14, 1993.

S. J. Ding, Properties and immersion behavior of magnetron-sputtered multi-layered hydroxyapatite/titanium composite coatings, Biomaterials, vol.24, issue.23, p.4233, 2003.
DOI : 10.1016/S0142-9612(03)00315-6

T. D. Driskell, Early History of Calcium Phosphate Materials and Coatings, p.3, 1994.
DOI : 10.1520/STP25177S

C. Ivanoff, C. Hallgren, and G. Widmark, Histologic evaluation of the bone integration of TiO2 blasted and turned titanium microimplants in humans, Clinical Oral Implants Research, vol.1, issue.2, pp.128-162, 2001.
DOI : 10.1111/j.1708-8208.1999.tb00087.x

K. Kieswetter, Z. Schwartz, and T. Hummert, Surface roughness modulates the local production of growth factors and cytokines by osteoblast-like MG-63 cells, Journal of Biomedical Materials Research, vol.25, issue.1, pp.55-63, 1996.
DOI : 10.1002/jbm.820250708

X. Liu, P. K. Chu, and C. Ding, Surface modification of titanium, titanium alloys, and related materials for biomedical applications, Materials Science and Engineering: R: Reports, vol.47, issue.3-4, pp.49-121, 2004.
DOI : 10.1016/j.mser.2004.11.001

J. Martin, Z. Schwartz, and T. Hummert, Effect of titanium surface roughness on proliferation, differentiation, and protein synthesis of human osteoblast-like cells (MG63), Journal of Biomedical Materials Research, vol.25, issue.3
DOI : 10.1177/00220345880670021701

W. Mueller, U. Gross, and T. Fritz, Evaluation of the interface between bone and titanium surfaces being blasted by aluminium oxide or bioceramic particles, Clinical Oral Implants Research, vol.9, issue.3
DOI : 10.1002/1097-4636(200105)55:2<151::AID-JBM1001>3.3.CO;2-4

E. Milella, F. Cosentino, and A. Licciulli, Preparation and characterisation of titania/hydroxyapatite composite coatings obtained by sol???gel process, Biomaterials, vol.22, issue.11, 1425.
DOI : 10.1016/S0142-9612(00)00300-8

S. Nishiguchi, T. Nakamura, and M. Kobayashi, The effect of heat treatment on bone-bonding ability of alkali-treated titanium, Biomaterials, pp.20-491, 1999.

A. Novaes, S. Souza, and P. De-oliveira, Histomorphometric analysis of the bone-implant contact obtained with 4 different implant surface treatments placed side by side in the dog mandible

M. Ohring, Materials Sciences of Thin Film: Deposition and Structure, p.277, 1991.

T. Peltola, M. Pätsi, H. Rahiala, and I. Kangasniemi, Calcium phosphate induction by sol-gel-derived titania coatings on titanium substrates in vitro, Journal Biomedical Materials. Res, vol.504, p.41, 1998.

L. Rasmusson, K. Kahnberg, and A. Tan, Effects of Implant Design and Surface on Bone Regeneration and Implant Stability: An Experimental Study in the Dog Mandible, Clinical Implant Dentistry and Related Research, vol.7, issue.1, pp.2-8, 2001.
DOI : 10.1034/j.1600-0501.1999.100506.x

B. Samuneva, V. Kozhukharov, and C. Trapalis, Sol-gel processing of titanium-containing thin coatings, Journal of Materials Science, vol.121, issue.9, p.2353, 1993.
DOI : 10.1002/masy.19880150128

Y. Shibata, M. Hosaka, and H. Kawai, Glow discharge plasma treatment of titanium plates enhances adhesion of osteoblastlike cells to the plates through the integrin-mediated mechanism

S. Vercaigne, J. G. Wolke, and I. Naert, Histomorphometrical and mechanical evaluation of titanium plasma-spray-coated implants placed in the cortical bone of goats, Journal of Biomedical Materials Research, vol.3, issue.1, pp.41-48, 1998.
DOI : 10.1016/S0883-5403(88)80034-2

A. Wennerberg, T. Albrektsson, B. Albrektsson, and J. Krol, Histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies

. Dans, nous avons détaillé les différents procédés de traitement de surface utilisés par l'industrie implantaire. Souvent un ou plusieurs traitements sont appliqués afin d'obtenir l'état de surface souhaité. Nous avons donc souhaité comparer l

. La-comparaison-de-l, état de surface des implants commercialisés a permis de mettre en évidence des différences entre ces implants, et l'absence d'une norme indépendante reconnue pour les états de surface des implants dentaires. Nous avons aussi noté l'absence d'un contrôle de qualité indépendant vis-à-vis des fabricants

. J. Jury:-pr and . Artis, Professeur 1 er grade Président Dr. P. BRAVETTI Maître de Conférences des Universités Juge Dr, MARTRETTE Maître de Conférences des Universités Juge Dr. N. TRAN Maître de Conférences des