I. Abrahamsson, T. Berglundh, J. Wennstrom, and J. Lindhe, The peri-implant hard and soft tissues at different implant systems. A comparative study in the dog., Clinical Oral Implants Research, vol.7, issue.3, pp.212-219, 1996.
DOI : 10.1034/j.1600-0501.1996.070303.x

I. Abrahamsson, T. Berglundh, and J. Lindhe, The mucosal barrier following abutment dis/reconnection. An experimental study in dogs, Journal of Clinical Periodontology, vol.13, issue.8, pp.568-572, 1997.
DOI : 10.1016/0142-9612(85)90104-8

I. Abrahamsson, T. Berglundh, P. Glantz, and J. Lindhe, The mucosal attachment at different abutments. An experimental study in dogs, Journal of Clinical Periodontology, vol.99, issue.9, pp.721-727, 1998.
DOI : 10.1023/A:1018579605426

I. Abrahamsson and T. Berglundh, Tissue Characteristics at Microthreaded Implants: An Experimental Study in Dogs, Clinical Implant Dentistry and Related Research, vol.3, issue.3, pp.107-113, 2006.
DOI : 10.1034/j.1600-0501.1998.090204.x

M. Araujo and J. Lindhe, Dimensional ridge alterations following tooth extraction. An experimental study in the dog, Journal of Clinical Periodontology, vol.43, issue.2, pp.212-218, 2005.
DOI : 10.1902/jop.1972.43.3.141

B. Assenza, Crestal Bone Remodeling in Loaded and Unloaded Implants and the Microgap: A Histologic Study, Implant Dentistry, vol.12, issue.3, pp.235-241, 2003.
DOI : 10.1097/01.ID.0000074081.17978.7E

C. Bain and D. Weng, A meta-analysis evaluating the risk for implant failure in patients who smoke, Compend Contin Educ Dent, vol.23, pp.695-699, 2002.

G. Bauman, J. Rapley, W. Hallman, and M. Mills, The peri-implant sulcus, International Journal of Oral and Maxillofacial Implants, vol.8, pp.273-280, 1993.

H. Baumgarten and R. Cocchetto, A new implant design for crestal bone preservation : initial obseravations and case report. Practical Procedures and Aesthetic Dentistry, pp.735-740, 2005.

J. Becker and D. Ferrari, Influence of platform switching on crestal bone changes at non-submerged titanium implants: a histomorphometrical study in dogs, Journal of Clinical Periodontology, vol.19, issue.12, pp.1089-1096, 2007.
DOI : 10.1034/j.1600-0501.1996.070102.x

J. Becker and D. Ferrari, Stability of crestal bone level at platform-switched non-submerged titanium implants: a histomorphometrical study in dogs, Journal of Clinical Periodontology, vol.19, issue.6, pp.532-539, 2009.
DOI : 10.1111/j.1600-051X.1995.tb00143.x

W. Becker, B. Becker, and H. Israelson, One-step surgical placement of Bränemark implants: A prospective multicenter clinical study, International Journal of Oral and Maxillofacial Implants, vol.12, pp.454-462, 1997.

T. Berglundh and J. Lindhe, The soft tissue barrier at implants and teeth, Clinical Oral Implants Research, vol.2, issue.2, pp.81-90, 1991.
DOI : 10.1034/j.1600-0501.1991.020206.x

T. Berglundh and J. Lindhe, Dimension of the periimplant mucosa. Biological width revisited, Journal of Clinical Periodontology, vol.22, pp.971-973, 1996.

D. Botticelli, T. Berglundh, and J. Lindhe, Hard-tissue alterations following immediate implant placement in extraction sites, Journal of Clinical Periodontology, vol.74, issue.10, pp.820-828, 2004.
DOI : 10.1902/jop.1997.68.11.1110

U. Brägger, U. Häfeli, and B. Huber, Evaluation of postsurgical crestal bone levels adjacent to non-submerged dental implants, Clinical Oral Implants Research, vol.9, issue.4, pp.218-224, 1998.
DOI : 10.1034/j.1600-0501.1998.090402.x

N. Broggini, L. Mcmanus, and J. Hermann, Persistent Acute Inflammation at the Implant-Abutment Interface, Journal of Dental Research, vol.82, issue.3, pp.232-237, 2003.
DOI : 10.1902/jop.1992.63.12.995

N. Broggini, L. Mcmanus, and J. Hermann, Peri-implant inflammation defined by the implantabutment interface, Clinical Oral Implants Research, vol.85, pp.473-478, 2006.

D. Buser, H. Weber, U. Brägger, and C. Balsiger, Tissue integration of one-stage ITI implants: 3-year results of a longitudinal study with hollow-cylinder and hollow-screw implants, Implant Dentistry, vol.1, issue.3, pp.405-412, 1991.
DOI : 10.1097/00008505-199200130-00016

J. Calvo-guirado and A. Ortiz-ruiz, Immediate loading and immediate restoration in 105 expanded-platform implants via Diem System after a 16-month follow-up period. Medicini Oral, Patologia Oral y Cyrurgia Bucal, pp.576-581, 2008.

J. Calvo-guirado, S. Yuguero, and M. , Immediate Provisionalization on a New Implant Design for Esthetic Restoration and Preserving Crestal Bone, Implant Dentistry, vol.16, issue.2, pp.155-164, 2007.
DOI : 10.1097/ID.0b013e31805816c9

J. Calvo-guirado and A. Ortiz-ruiz, Immediate maxillary restoration of single-tooth implants using platform switching for crestal bone preservation, International Journal of Oral and Maxillofacial Implants, vol.24, issue.2, pp.275-281, 2009.

S. Canay and K. Akça, Biomechanical Aspects of Bone-Level Diameter Shifting at Implant-Abutment Interface, Implant Dentistry, vol.18, issue.3, pp.239-248, 2009.
DOI : 10.1097/ID.0b013e318198ffd1

L. Canullo and G. Rasperini, Preservation of peri-implant soft and hard tissues using platform switching of implants placed in immediate extraction sockets: a proof-of-concept study with 12-to 36-month follow-up, International Journal of Oral and Maxillofacial Implants, vol.22, issue.6, pp.995-1000, 2007.

L. Canullo, . Goglia-g, G. Iurlaro, and G. Iannello, Short-term bone level observations associated with platform switching in immediate placed and restored single maxillary implant: a preliminary report, International Journal of Prosthodondics, vol.22, issue.3, pp.277-282, 2009.

L. Canullo, G. Iurlaro, and G. Iannello, Double-blind randomized controlled trial study on post-extraction immediately restored implants using the switching platform concept: soft tissue response. Preliminary report, Clinical Oral Implants Research, vol.15, issue.4, pp.414-420, 2009.
DOI : 10.1902/jop.1997.68.2.186

L. Canullo, G. Fedele, G. Iannello, and S. Jepsen, Platform switching and marginal bone-level alterations: the results of a randomized-controlled trial, Clinical Oral Implants Research, vol.11, issue.1, pp.115-121, 2010.
DOI : 10.1111/j.1600-051X.2007.01158.x

L. Canullo, A. Quanranta, and R. Teles, The Microbiota Associated With Implants Restored With Platform Switching: A Preliminary Report, Journal of Periodontology, vol.17, issue.3, pp.403-411, 2010.
DOI : 10.1111/j.1600-051X.1998.tb02419.x

M. Cappiello and R. Luongo, Evaluation of peri-implant bone loss around platform-switched implants, The International Journal of Periodontics & Restorative Dentistry, vol.28, issue.4, pp.347-355, 2008.

D. Cecchinato, C. Olsson, and J. Lindhe, Submerged or non-submerged healing of endosseous implants to be used in the rehabilitation of partially dentate patients. A multicenter, randomized controlled clinical trial, Journal of Clinical Periodontology, vol.3, issue.1, pp.299-308, 2004.
DOI : 10.1034/j.1600-0501.1996.070102.x

C. Chang, C. Chen, and M. Hsu, Biomechanical effect of platform switching in implant dentistry: a three-dimensional finite element analysis, International Journal of Oral and Maxillofacial Implants, vol.25, issue.2, pp.295-304, 2010.

D. Chauvel-lebret and P. Auroy, Evaluation de la genotoxicié des biomatériaux finis par la technique des comètes. Actualités en biomatériaux, pp.405-412, 2002.

V. Choquet and M. Hermans, Clinical and Radiographic Evaluation of the Papilla Level Adjacent to Single-Tooth Dental Implants. A Retrospective Study in the Maxillary Anterior Region, Journal of Periodontology, vol.17, issue.10, pp.1364-1371, 2001.
DOI : 10.1111/j.1600-051X.1982.tb02106.x

V. Comte, C. Lagneau, and M. Lissac, Comportement des fibroblastes gingivaux sur différents alliages de titane (Ticp, Ti-6Al-4v, NiTi) Actualités en biomatériaux, pp.505-510, 2002.

A. Comut and H. Weber, Connective tissue orientation around dental implants in a canine model, Clinical Oral Implants Research, vol.52, issue.5, pp.433-440, 2001.
DOI : 10.1902/jop.1981.52.9.465

R. Crespi and P. Capparè, Radiographic evaluation of marginal bone levels around platform-switched and non-platform-switched implants used in an immediate loading protocol, International Journal of Oral and Maxillofacial Implants, vol.24, issue.5, pp.920-926, 2009.

M. Davarpanah and S. Szmukler-moncler, Théorie et pratique de la mise en charge immediate, Quintessence International, 2007.

J. Davies, Understanding peri-implant endosseous healing, Journal of Dental Education, vol.67, pp.932-949, 2003.
DOI : 10.1201/9780203491430.ch12

M. Degidi, G. Iezzi, A. Scarano, and A. Piattelli, Immediately loaded titanium implant with a tissue-stabilizing/maintaining design (???beyond platform switch???) retrieved from man after 4 weeks: a histological and histomorphometrical evaluation. A case report, Clinical Oral Implants Research, vol.64, issue.16, pp.276-282, 2007.
DOI : 10.1902/jop.1993.64.5.374

S. Deshpande, S. Sarin, and R. Parkhedkar, Platform switched of dental implants : Panacea for crestal bone loss? Journal of Clinical and Diagnostic Research, pp.1348-1352, 2009.

B. Engquist and P. Ästrand, Marginal bone reaction to oral implants : A prospective comparative study of Astra Tech and Bränemark System implants, Clinical Oral Implants Research, vol.13, pp.30-37, 2002.

I. Ericsson, L. Persson, and T. Berglundh, Different types of inflammatory reactions in periimplant soft tissues, Journal of Clinical Periodontology, vol.22, p.225, 1995.

I. Ericsson, K. Nilner, B. Klinge, and P. Glantz, Radiographical and histological characteristics of ssubmerged and nonsubmerged titanium implants. An experimental study in the Labrador dog., Clinical Oral Implants Research, vol.7, issue.1, pp.20-26, 1996.
DOI : 10.1034/j.1600-0501.1996.070103.x

M. Esposito, J. Hirsch, U. Lekholm, and P. Thomsen, Biological factors contributing to failures of osseointegrated oral implants, (I). Success criteria and epidemiology, European Journal of Oral Sciences, vol.106, issue.1, pp.527-551, 1998.
DOI : 10.1046/j.0909-8836..t01-2-.x

S. Feldman and N. Boitel, Five-Year Survival Distributions of Short-Length (10 mm or less) Machined-Surfaced and Osseotite?? Implants, Clinical Implant Dentistry and Related Research, vol.74, issue.1, pp.16-23, 2004.
DOI : 10.1902/jop.2003.74.7.945

J. Fiorellini and D. Buser, A Radiographic Evaluation of Bone Healing Around Submerged and Non-Submerged Dental Implants in Beagle Dogs, Journal of Periodontology, vol.41, issue.1, pp.248-254, 1999.
DOI : 10.1902/jop.1970.41.10.551

B. Friberg, A. Ekkestubbe, and L. Sennerby, Clinical outcome of Bränemeark system implants of various diameters: a retrospective study, International Journal of Oral and Maxillofacial Implants, vol.17, pp.671-677, 2002.

D. Gardner, Platform switching as ameans to achieving implant esthetics, New York State Dental Journal, vol.71, issue.3, pp.34-37, 2005.

G. E. Romanos and G. Nentwig, Immediate functional loading in the maxilla using implants with platform switching: five year result, International Journal of Oral and Maxillofacial Implants, vol.24, pp.1106-1112, 2009.

J. Guindy, H. Schield, F. Schmidle, and J. Wirz, Corrosion at the marginal gap of implant supported superstructures and implant failure, International Journal of Oral and Maxillofacial Implants, vol.19, pp.826-831, 2004.

N. Hallab and K. Bundy, Evaluation of Metallic and Polymeric Biomaterial Surface Energy and Surface Roughness Characteristics for Directed Cell Adhesion, Tissue Engineering, vol.7, issue.1, pp.55-71, 2001.
DOI : 10.1089/107632700300003297

M. Harmand, Evaluation in vitro des biomatériaux à usage odontologique à l'aide de cellules d'origine humaine. Actualité en biomatériaux, pp.273-277, 1993.

G. Hartman and D. Cochran, Initial Implant Position Determines the Magnitude of Crestal Bone Remodeling, Journal of Periodontology, vol.1, issue.4, pp.572-577, 2004.
DOI : 10.1902/jop.2000.71.4.546

L. Hellden, G. Ericson, and A. Elliot, A prospective 5-year multi-center study of the Cresco implantology concept, The International Journal of Prosthodontics, vol.16, pp.554-562, 2003.

F. Hermann, H. Lerner, and A. Palti, Factors Influencing the Preservation of the Periimplant Marginal Bone, Implant Dentistry, vol.16, issue.2, pp.165-175, 2007.
DOI : 10.1097/ID.0b013e318065aa81

J. Hermann, D. Cochran, P. Nummikoski, and D. Buser, Crestal Bone Changes Around Titanium Implants. A Radiographic Evaluation of Unloaded Nonsubmerged and Submerged Implants in the Canine Mandible, Journal of Periodontology, vol.11, issue.11, pp.1117-1130, 1997.
DOI : 10.1016/0030-4220(59)90078-7

J. Hermann and D. Buser, Biologic width around titanium implants. A physiologically formed and stable dimension over time, Clinical Oral Implants Research, vol.11, issue.1, pp.1-11, 2000.
DOI : 10.1034/j.1600-0501.2000.011001001.x

J. Hermann, J. Schoolfield, R. Schenk, D. Buser, and D. Cochran, Biologic Width around one- and two-piece titanium implants. A histometric evaluation of unloaded nonsubmerged and submerged implants in the canine mandible, Clinical Oral Implants Research, vol.12, issue.6, pp.559-571, 2001.
DOI : 10.1034/j.1600-0501.1996.070102.x

J. Hermann, J. Schoolfield, R. Schenk, D. Buser, and D. Cochran, Influence of the Size of the Microgap on Crestal Bone Changes Around Titanium Implants. A Histometric Evaluation of Unloaded Non-Submerged Implants in the Canine Mandible, Journal of Periodontology, vol.14, issue.10, pp.1372-1383, 2001.
DOI : 10.1034/j.1600-051X.1999.260907.x

J. Hermann, J. Schoolfield, P. Nummikoski, R. Schenk, D. Buser et al., Crestal bone changes around titanium implants: A methodologic study comparing linear radiographic with histomorphometric measurements, International Journal of Oral and Maxillofacial Implants, vol.16, pp.475-485, 2001.

J. Hsu and L. Fuh, Bone Strain and Interfacial Sliding Analyses of Platform Switching and Implant Diameter on an Immediately Loaded Implant: Experimental and Three-Dimensional Finite Element Analyses, Journal of Periodontology, vol.13, issue.7, pp.1125-1132, 2009.
DOI : 10.1067/mpr.2001.115251

R. Hunt, J. Gartner, and F. Norkin, Choice of a dental implant system, Compend Contin Educ Dent, vol.26, pp.239-240, 2005.

M. Hürzeler, S. Fickl, O. Zuhr, and H. Wachtel, Peri-Implant Bone Level Around Implants With Platform-Switched Abutments: Preliminary Data From a Prospective Study, Journal of Oral and Maxillofacial Surgery, vol.65, issue.7, pp.33-39, 2007.
DOI : 10.1016/j.joms.2007.03.024

M. Hürzeler, S. Fickl, O. Zuhr, and H. Wachtel, Peri-implant bone level around implants with platformswitched abutments: preliminary data from a prospective study, Journal of Oral and Maxillofacial Surgery, vol.66, issue.10, pp.2195-2196, 2008.

F. Isidor, Influence of forces on peri-implant bone, Clinical Oral Implants Research, vol.19, issue.S2, pp.8-18, 2006.
DOI : 10.1034/j.1600-0501.2002.130206.x

V. Jansen, G. Conrads, and E. Richter, Microbial leakage and marginal fit of the implant-abutment interface, International Journal of Oral and Maxillofacial Implants1997, vol.12, pp.527-540

R. Jung and A. Jones, The Influence of Non-Matching Implant and Abutment Diameters on Radiographic Crestal Bone Levels in Dogs, Journal of Periodontology, vol.20, issue.2, pp.260-270, 2008.
DOI : 10.1111/j.1708-8208.2002.tb00161.x

G. King and J. Hermann, Influence of the Size of the Microgap on Crestal Bone Levels in Non-Submerged Dental Implants: A Radiographic Study in the Canine Mandible, Journal of Periodontology, vol.1, issue.10, pp.1111-1117, 2002.
DOI : 10.1111/j.1399-302X.1987.tb00298.x

R. Lazzara and S. Poter, Platform switching: a new concept in implant dentistry for controlling postrestorative crestal bone levels, The International Journal of Periodontics & Restorative Dentistry, vol.26, issue.1, pp.9-17, 2006.

D. Levy, D. Deporter, M. Pharoah, and G. Tomlinson, A comparison of radiographic bone height and probing attachment level measurements adjacent to porous-coated dental implants in humans, International Journal of Oral and Maxillofacial Implants, vol.12, pp.541-546, 1997.

Q. Li and Y. Lin, Clinical study of application of platform switching to dental implant treatment in esthetic zone, Zhonghua Kou Qiang Yi Xue Za Zhi, vol.43, issue.9, pp.537-541, 2008.

X. Liu, Z. Li, and H. Xia, Influence of implant-abutment connection mode on stress distribution in peri-implant bone, Zhonghua Kou Qiang Yi Xue Za Zhi, vol.43, issue.1, pp.50-53, 2008.

L. Lopez-mari and J. Calvo-guirado, Implant platform switching concept: an update review. Medicini Oral, Patologia Oral y Cyrurgia Bucal, pp.450-454, 2009.

R. Luongo and T. Traini, Hard and soft tissue responses to the platform-switching technique, The International Journal of Periodontics & Restorative Dentistry, vol.28, issue.6, pp.551-557, 2008.

Y. Maeda, J. Miura, I. Taki, and M. Sogo, Biomechanical analysis on platform switching: is there any biomechanical rationale? Clinical Oral Implants Research, pp.581-584, 2007.
DOI : 10.1111/j.1600-0501.2007.01398.x

J. Martin and D. Dean, Proliferation, differentiation, and protein synthesis of human osteoblast-like cells (MG63) cultured on previously used titanium surfaces, Clinical Oral Implants Research, vol.7, issue.1, pp.27-37, 1996.
DOI : 10.1034/j.1600-0501.1996.070104.x

S. Mifsud, C. Lagneau, B. Grosgogeat, and C. Lissac, Influence des procédés de stérilisation et de désinfection sur la biocompatibilité des matériaux à base de titane. Actualités en biomatériaux, pp.439-445, 2002.

A. Mombelli, M. Van-oosten, E. Schurch, . Jr, and N. Lang, The microbiota associated with successful or failing osseointegrated titanium implants. Oral Microbiology and Immunology, pp.145-151, 1987.

N. Nardin, Mécanismes d'adhésion et systèmes biologiques Actualités en biomatériaux, pp.121-138, 2002.

A. Novaes, . Jr, R. Oliveira, and V. Muglia, The Effects of Interimplant Distances on Papilla Formation and Crestal Resorption in Implants With a Morse Cone Connection and a Platform Switch: A Histomorphometric Study in Dogs, Journal of Periodontology, vol.15, issue.11, pp.1839-1849, 2006.
DOI : 10.1034/j.1600-0501.1993.040307.x

L. Persson, U. Lekholm, A. Leonhardt, G. Dahlén, and J. Lindhe, Bacterial colonization on internal surfaces of Branemark systemR implant components, Clinical Oral Implants Research, vol.7, issue.2, pp.90-95, 1996.
DOI : 10.1034/j.1600-0501.1996.070201.x

A. Pham and J. Fiorellini, Longitudinal radiographic study of crestal bone levels adjacent to non-submerged dental implants, Journal of Oral Implantology, vol.20, pp.26-34, 1994.

G. Priest, The Esthetic Challenge of Adjacent Implants, Journal of Oral and Maxillofacial Surgery, vol.65, issue.7, pp.2-12, 2007.
DOI : 10.1016/j.joms.2007.03.015

L. Prosper and S. Redaelli, A randomized prospective multicenter trial evaluating the platformswitching technique for the preservation of postrestorative crestal bone loss, International Journal of Oral and Maxillofacial Implants, vol.24, issue.2, pp.299-308, 2009.

M. Ricci and P. Tonelli, Bone maintenance around dental implant : The role of platform switching, Dental Cadmos, vol.77, issue.9, pp.31-39, 2009.

X. Rodriguez-ciurana and X. Vela-nebot, The effect of interimplant distance on the height of the interimplant bone crest when using platform-swithed implants, The International Journal of Periodontics & Restorative Dentistry, vol.29, issue.2, pp.141-151, 2009.

X. Rodriguez-ciurana and X. Vela-nebot, Biomechanical repercussions of bone resorption related to biologic width : a finite element analysis of three implant-abutment configurations, The International Journal of Periodontics & Restorative Dentistry, vol.29, issue.5, pp.479-487, 2009.

G. Romanos and G. Nentwig, Immediate functional loading in the maxilla using implants with platform switching: five-year results, International Journal of Oral and Maxillofacial Implants, vol.24, issue.6, pp.1106-1112, 2009.

E. Rompen and O. Domken, The effect of material characteristics, of surface topography and of implant components and connections on soft tissue integration: a literature review, Clinical Oral Implants Research, vol.16, issue.S2, pp.55-67, 2006.
DOI : 10.1034/j.1600-0501.1996.070402.x

A. Saadoun, L. Gall, M. Touati, and B. , Current trends in implantology. Part2. Treatment planning, aesthetic considerations and tissue regeneration. Practical Procedures and Aesthetic Dentistry, pp.707-714, 2004.

A. Saadoun and B. Touati, Soft tissue recession around implants: is it still unavoidable? Part 1. . Practical Procedures and Aesthetic Dentistry, pp.55-62, 2007.

A. Schroeder, E. Van-der-zypen, H. Stich, and F. Sutter, The reactions of bone, connective tissue, and epithelium to endosteal implants with titanium-sprayed surfaces, Journal of Maxillofacial Surgery, vol.9, pp.15-25, 1981.
DOI : 10.1016/S0301-0503(81)80007-0

J. Schrotenboer and Y. Tsao, Effect of microthreads and platform switching on crestal bone stress levels:A finite element analysis, Journal of Periodontology, vol.11, pp.2166-2172, 2008.

J. Schrotenboer and Y. Tsao, Effect of Platform Switching on Implant Crest Bone Stress: A Finite Element Analysis, Implant Dentistry, vol.18, issue.3, pp.260-269, 2009.
DOI : 10.1097/ID.0b013e31819e8c1d

M. Shalabi and A. Gortemaker, Implant Surface Roughness and Bone Healing: a Systematic Review, Journal of Dental Research, vol.85, issue.6, pp.496-500, 2006.
DOI : 10.1016/0142-9612(96)80750-2

L. Silverstein, M. Lefkove, and J. Garnick, The use of free gingival soft tissue to improve the implant/soft tissue interface, J Oral Implantol, vol.20, pp.36-40, 1994.

L. Silverstein and M. Lefkove, The use of the subepithelial connective tissue graft to enhance both the aesthetics and periodontal contours surrounding dental implants, J Oral Implantol, vol.20, pp.135-138, 1994.

R. Stach and S. Kohles, A Meta-Analysis Examining the Clinical Survivability of Machined-Surfaced and Osseotite Implants in Poor-Quality Bone, Implant Dentistry, vol.12, issue.1, pp.87-96, 2003.
DOI : 10.1097/01.ID.0000042507.37401.6F

A. Stavropoulos, T. Karring, and L. Kostopoulos, Fully vs. partially rough implants in maxillary sinus floor augmentation: a randomized-controlled clinical trial, Clinical Oral Implants Research, vol.13, issue.1, pp.95-102, 2007.
DOI : 10.1016/S1079-2104(98)90391-2

J. Steigenga and K. Shammari, Dental Implant Design and Its Relationship to Long-Term Implant Success, Implant Dentistry, vol.12, issue.4, pp.306-317, 2003.
DOI : 10.1097/01.ID.0000091140.76130.A1

L. Steinebrunner, L. Wolfart, K. Bössmann, and M. Kern, In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems, International Journal of Oral and Maxillofacial Implants, vol.20, pp.875-881, 2005.

T. Sugiura, K. Horiuchi, M. Sugimura, and S. Tsutsumi, Evaluation of threshold stress for bone resorption around screws based on in vivo strain measurement of miniplate, Journal of Musculoskeletal and Neuronal Interaction, vol.1, pp.165-170, 2000.

S. Szmukler-moncler and F. Figuereido, Immediate loading of single crowns retained by short implants. A histologic study with various surfaces in the canine mandible, Clinical Oral Implants Research, vol.11, p.373, 2000.

L. Tabata and W. Assunçao, Implant Platform Switching, Journal of Craniofacial Surgery, vol.21, issue.1, pp.182-187, 2010.
DOI : 10.1097/SCS.0b013e3181c50eb8

D. Tarnow, A. Magner, and P. Fletcher, The Effect of the Distance From the Contact Point to the Crest of Bone on the Presence or Absence of the Interproximal Dental Papilla, Journal of Periodontology, vol.29, issue.12, pp.995-996, 1992.
DOI : 10.1016/0030-4220(61)90290-0

D. Tarnow, S. Cho, and S. Wallace, The Effect of Inter-Implant Distance on the Height of Inter-Implant Bone Crest, Journal of Periodontology, vol.12, issue.4, pp.546-549, 2000.
DOI : 10.1902/jop.1992.63.12.995

D. Tarnow, N. Elian, and S. Cho, Vertical Distance from the Crest of Bone to the Height of the Interproximal Papilla Between Adjacent Implants, Journal of Periodontology, vol.15, issue.12, pp.1785-1788, 2003.
DOI : 10.1034/j.1600-0501.2000.011001001.x

T. Testori, L. Wiseman, S. Woolfe, and S. Porter, A prospective multicenter clinical study of the Osseotite implant: four-year interim report, International Journal of Oral and Maxillofacial Implants, vol.16, pp.193-200, 2001.

K. Trammell and N. Geurs, A prospective, randomized, controlled comparison of platformswitched and matched-abutment implants in short-span partial denture situations, The International Journal of Periodontics & Restorative Dentistry, vol.29, issue.6, pp.599-605, 2009.

C. Tuner, On Wolff's law of trabecular architecture, Journal of Biomechanics, vol.25, issue.1, pp.1-9, 1992.
DOI : 10.1016/0021-9290(92)90240-2

X. Vela-nebot, X. Rodriguez-ciurana, C. Rodado-alonso, and M. Segalà-torres, Benefits of an Implant Platform Modification Technique to Reduce Crestal Bone Resorption, Implant Dentistry, vol.15, issue.3, pp.313-320, 2006.
DOI : 10.1097/01.id.0000226788.19742.32

P. Vigolo and A. Givani, Platform-switched restorations on wide-diameter implants: a 5 year clinical prospective study, International Journal of Oral and Maxillofacial Implants, vol.24, issue.1, pp.103-109, 2009.

J. Waerhaug, Subgigival plaque and loss of attachment in periodontosis as evaluated on extracted teeth, Journal of Periodontology, vol.45, p.125, 1977.

B. Wagenberg and S. Froum, Prospective study of 94 platform-switched implants observed from, The International Journal of Periodontics & Restorative Dentistry, vol.30, issue.1, pp.9-17, 1992.

H. Weber, C. Crohin, and J. Fiorellini, A 5-year prospective clinical and radiographic study of non-submerged dental implants, Clinical Oral Implants Research, vol.11, issue.2, pp.144-153, 2000.
DOI : 10.1034/j.1600-0501.2000.110207.x

M. Weng-dn-nagata, Influence of microgap location and configuration on the pri-implant bone morphology in submerged implants. An experimental study in dogs, Clinical Oral Implants Research, vol.11, pp.1141-1147, 2008.

R. Weyant, Characteristics associated with the loss and peri-implant tissue health of endosseous dental implants, International Journal of Oral and Maxillofacial Implants, vol.9, pp.95-102, 1994.

L. Zetterqvist and S. Feldman, A prospective, randomized-controlled study of hybrid and nonhybrid DAE implants for the incidence of periimplantitis: a three-year interim evaluation. Academy of Osseointegration, 2006.