A. S. , Titanium in industry : technology of structural titanium, 1955.

A. Weiner and S. , Effect of an antirotation resistance form on screw loosening for single implant-supported crowns, The Journal of Prosthetic Dentistry, vol.83, pp.450-455, 2000.

A. Berglundh-t, The mucosal barrier following abutment dis/reconnection. An experimental study in dogs, Journal of Clinical Periodontology. août 1997, vol.24, pp.568-572

A. , Tissue characteristics at microthreaded implants: an experimental study in dogs, Clinical Implant Dentistry and Related Research. 2006, vol.8, pp.107-113

A. L. Rafee, M. A. , N. Ww, F. Ra, D. Vb et al., The effect of repeated torque on the ultimate tensile strength of slotted gold prosthetic screws. The Journal of Prosthetic Dentistry, vol.88, pp.176-182, 2002.

A. , Z. G. , and W. P. Eriksson-ar, The LongTerm Efficacy of Currently Used Dental Implants: A Review and Proposed Criteria of Success, International Journal of Oral & Maxillofacial Implants. 1986, vol.1, issue.1, pp.11-25

A. Sertgöz-a, Influence of occlusal forces on stress distribution in preloaded dental implant screws. The Journal of Prosthetic Dentistry, vol.91, pp.319-325, 2004.

A. W. , W. Ed, and K. Cj, Effects of repeated drill use on temperature of bone during preparation for osteosynthesis self-tapping screws, British Journal of Oral and Maxillofacial Surgery. août, vol.43, pp.314-319, 2005.

A. , C. Jm, and E. , Matériaux utilisées pour l'ostéosynthèse. EMC Techniques chirurgicales orthopédie traumatologie, vol.44, pp.1-6, 2007.

A. , Récuperation d'élements fracturés d'un système implantaire vissé : implications prothétiques. Les cahiers de prothèses. mars 1999. n° 105, pp.33-53

A. Kj, Standardizing failure, success, and survival decisions in clinical studies of ceramic and metal-ceramic fixed dental prostheses, Dental Materials. janvier 2012, vol.28, issue.1, pp.102-111

A. Scarano-a, L. G. , C. G. , T. U. , and R. Fs, Screw-vs cement-implant-retained restorations: an experimental study in the Beagle. Part 1. Screw and abutment loosening, The Journal of Oral Implantology, vol.31, issue.5, pp.242-246, 2005.

A. Wg, B. Var, J. A. Delben, G. Éa, and G. Jrir, Effect of unilateral misfit on preload of retention screws of implant-supported prostheses submitted to mechanical cycling, Journal of Prosthodontic Research. janvier, vol.55, issue.1, pp.12-18, 2011.

A. and M. Sm, Photoelastic stress analysis of external versus internal implant-abutment connections. The Journal of Prosthetic Dentistry, vol.106, pp.266-271, 2011.

A. and G. Jm, Implants et cantilever : Analyse par la méthode des éléments finis. Réalités cliniques, vol.3, pp.345-357, 1992.

B. Zhang, Y. Thompson-van, P. , R. Ed, and S. Cfj, Reliability and failure modes of implant-supported zirconium-oxide fixed dental prostheses related to veneering techniques, Journal of Dentistry. juillet, vol.39, pp.489-498, 2011.

B. C. , Incidence des caractéristiques de l'implant et de la jonction implantoprothétique sur l'intégration biologique, conséquences esthétiques, vol.245, 2007.

B. , S. , P. S. Vazquez-l, and B. Uc, The anchorage of Brånemark and ITI implants of different lengths. I. An experimental study in the canine mandible, Clinical Oral Implants Research. octobre, vol.14, issue.5, pp.593-600, 2003.

B. M. , Complications et echecs en implantologie, 1994.

B. M. , Fracture d'une vis de pilier, Alternatives, vol.3, p.124, 1999.

B. J. , An Introduction to the Design and Behavior of Bolted Joints, Third Edition, Revised and Expanded

B. Pp, Evaluation of machining accuracy and consistency of selected implants, standard abutments, and laboratory analogs, The International Journal of Prosthodontics. avril, vol.8, issue.2, pp.162-178, 1995.

B. Pp, The effect of implant/abutment hexagonal misfit on screw joint stability, The International Journal of Prosthodontics. avril 1996, vol.9, issue.2, pp.149-160

B. Pp, The spline implant: design, engineering, and evaluation, The International Journal of Prosthodontics. octobre 1996, vol.9, issue.5, pp.419-433

B. Pp, Implants and components: entering the new millennium, The International Journal of Oral & Maxillofacial Implants. février, vol.15, issue.1, pp.76-94, 2000.

B. Pp and M. Mj, The effect of eliminating implant/abutment rotational misfit on screw joint stability, The International Journal of Prosthodontics. décembre 1996, vol.9, pp.511-519

B. Pp, Evaluation of the effectiveness of a technique to prevent screw loosening. The Journal of Prosthetic Dentistry, vol.79, pp.430-432, 1998.

B. Pi, A. R. Breine-u, H. Bo, and L. Ohlsson-a, Experimental studies on intra-osseous anchorage of dental prosthesis, Scanddinavian Journal of Plastic and Reconscructive Surgery. 1969, vol.3, pp.81-100

B. Lc, D. Dl, N. Ew, and T. Jd, Torque Required to Loosen Single-Tooth Implant Abutment Screws Before and After Simulated Function, International Journal of Prosthodontics. octobre 1993, vol.6, issue.5, pp.435-439

B. U. , The ZiReal Post: A new ceramic implant abutment, Journal of Esthetic and Restorative Dentistry, vol.15, issue.1, pp.10-23, 2003.

B. , M. Lm, H. Js, . Medina-r, . Schenk-rk et al., Peri-implant inflammation defined by the implant-abutment interface, Journal of Dental Research. mai, vol.85, issue.5, pp.473-478, 2006.

B. , M. Lm, H. Js, M. Ru, O. Tw et al., Persistent acute inflammation at the implant-abutment interface, Journal of Dental Research. mars, vol.82, pp.232-237, 2003.

B. Rl, J. Rb, and K. T. Patterson-ea, Tightening characteristics for screwed joints in osseointegrated dental implants, The Journal of Prosthetic Dentistry. juin, vol.71, pp.592-599, 1994.

B. and B. Uc, Early loading of non submerged titanium implants, with a sand blasted and etched surface 5 year results of a prospective study in partially edentulous patients, Clinical Oral Implants Research, vol.16, p.63, 2005.

B. Jacobs-s, O. , H. F. , and C. , Preloads Generated with Repeated Tightening in Three Types of Screws Used in Dental Implant Assemblies, Journal of Prosthodontics. mai, vol.15, pp.164-171, 2006.

C. , Preload loss in gold prosthesis-retaining screws as a function of time, The International Journal of Oral & Maxillofacial Implants. février 2004, vol.19, issue.1, pp.124-132

C. and B. Fa, Preventing loosening of implant abutment screws. The Journal of Prosthetic Dentistry, vol.75, pp.566-569, 1996.

C. , L. , O. , S. , and C. , Fractographic analysis of fractured dental implant components, Journal of Dental Sciences. mars 2013, vol.8, issue.1, pp.8-14, 2013.

C. Hc, L. Ch, J. Yh, S. Ko-ym, C. Mk et al., Fatigue Fracture of Implant System Using TiN and WC Coated Abutment Screw. Procedia Engineering, vol.10, pp.680-685, 2011.

C. Rm, N. Sk, L. Br, and R. Fa, Examination of the implant-abutment interface after fatigue testing, The Journal of Prosthetic Dentistry. mars, vol.85, pp.268-275, 2001.

C. Pg, P. Sudack, K. Suzuki-m, R. Ks, S. Ge et al., In vitro evaluation of the implant abutment connection sealing capability of different implant systems, Journal of Oral Rehabilitation. décembre, vol.35, pp.917-924, 2008.

C. Ar, B. E. , D. E. Mattos-mgc, R. Rcs, S. Iam et al., Fracture resistance of the implant-abutment connection in implants with internal hex and internal conical connections under oblique compressive loading: an in vitro study, The International Journal of Prosthodontics. juin, vol.22, pp.283-286, 2009.

C. Ar, F. Acl, D. E. Mattos-mgc, R. Rcs, S. Ja et al., Mechanical comparison of experimental conical-head abutment screws with conventional flat-head abutment screws for external-hex and internal trichannel implant connections: an in vitro evaluation of loosening torque, The International Journal of Oral & Maxillofacial Implants. décembre 2013, vol.28, issue.6, pp.321-329

D. and J. L. Blind-o, Axial displacement of abutments into implants and implant replicas, with the tapered cone-screw internal connection, as a function of tightening torque. The International Journal of Oral & Maxillofacial Implants, vol.24, pp.251-256, 2009.

D. , J. , and C. , Les implants en odontologie. Cdp, 2004.

D. and M. Ss, Manuel d'implantologie clinique: concepts, protocoles et innovations récentes. 2 e édition, 2011.

D. M. , Manuel d'implantologie clinique. 1 ière édition, 1999.

D. E. Torres, E. M. , R. Rcs, D. E. Mattos-mgc, and R. Rf, The effect of commercially pure titanium and alternative dental alloys on the marginal fit of one-piece cast implant frameworks, Journal of Dentistry. octobre, vol.35, pp.800-805, 2007.

D. and C. , Effects of infection control procedures on the accuracy of a new mechanical torque wrench system for implant restorations, The Journal of Prosthetic Dentistry. janvier, vol.75, issue.1, pp.93-98, 1996.

D. Nguyen-y and C. , La mise en charge immédiate des restaurations implanto portée dans le traitement de l'edenté complet mandibulaire. 1ière partie : analyse de la littérature et facteurs de réussite chirurgicaux, Implantologie, vol.14, issue.2, pp.71-80, 2005.

D. Mp, D. S. Borchers-l, . Kohorst-p, and . Stiesch-m, Influence of the interface design on the yield force of the implant-abutment complex before and after cyclic mechanical loading, Journal of Prosthodontic Research. janvier, vol.56, issue.1, pp.19-24, 2012.

D. Dl, B. Lc, S. Jp, and M. Ml, Comparison of screw loosening, rotation, and deflection among three implant designs. The Journal of Prosthetic Dentistry. septembre 1995, vol.74, pp.270-278

D. Ehrenfest, D. M. , C. Pg, K. Sul-y-t, and A. , Classification of osseointegrated implant surfaces: materials, chemistry and topography, Trends in Biotechnology. avril 2010, vol.28, pp.198-206

D. , Failure of oral implants: aetiology, symptoms and influencing factors, Clinical Oral Investigations. septembre, vol.2, pp.102-114, 1998.

E. , C. U. Eriksson-t, L. U. , L. S. , and R. T. , A retrospective analysis of factors associated with multiple implant failures in maxillae, Clinical Oral Implants Research. octobre, vol.12, issue.5, pp.462-467, 2001.

E. Cn, F. Dc, and R. Pr, Influence of the coating material on the loosing of dental implant abutment screw joints, Materials Science and Engineering: C. septembre, vol.26, pp.1361-1366, 2006.

E. and M. J. , Décisions cliniques et plans de traitement en ostéointégration. Quintessence internation. USA : Quintessence international, 1998.

E. T. Le, Stratégie prothétique. juin 2003, vol.3, pp.167-207

F. Ap, S. Ao, X. Consani-rl, and M. Mf, Screw joint stability after the application of retorque in implant-supported dentures under simulated masticatory conditions, The Journal of Prosthetic Dentistry. juin, vol.111, pp.499-504, 2014.

F. Delgado-l, M. M. , and G. , Analysis of the misfit of dental implant-supported prostheses made with three manufacturing processes, The Journal of Prosthetic Dentistry. février, vol.111, issue.2, pp.116-123, 2014.

F. Cc, A. Rb, D. E. Almeida-eo, F. Júnior-ac, F. Fc et al., Influence of microthreads and platform switching on stress distribution in bone using angled abutments, Journal of Prosthodontic Research. octobre, vol.56, pp.256-263, 2012.

F. Jkw, P. Judge-rb, . Je, and . Swain-mv, Fracture resistance of titanium and zirconia abutments: An in vitro study, The Journal of Prosthetic Dentistry. mai 2013, vol.109, issue.5, pp.304-312

G. L. , Risk factors in implant dentistry, British Dental Journal. 26 juillet, vol.205, issue.2, pp.109-109, 2008.

G. Bigolin-g, F. F. Bürgin-w, and . Brägger-u, Implants with original and non-original abutment connections. Clinical Implant Dentistry and Related Research, vol.16, pp.303-311, 2014.

G. Fj, E. E. Rodriguez-a, L. Jm, and P. E. , Effect of oral bacteria on the mechanical behavior of titanium dental implants. The International Journal of Oral & Maxillofacial Implants, vol.27, pp.64-68, 2012.

G. Cj, R. Bernal-g, and . Kan-jyk, Clinical complications with implants and implant prostheses, The Journal of Prosthetic Dentistry. août, vol.90, issue.2, pp.121-132, 2003.

G. Sl, J. Ce, S. Aa, and . Beaty-kd, Wide diameter implants: indications, considerations and preliminary results over a two-year period, Australian Prosthodontic Journal. 1994, vol.8, pp.31-37

G. Kozak-d, L. Bz, and W. Ei, Manual closing torque in five implant abutment systems: an in vitro comparative study. The Journal of Prosthetic Dentistry, vol.81, pp.574-578, 1999.

G. , R. Ta, L. La, and M. Hr, Probabilistic analysis of preload in the abutment screw of a dental implant complex. The Journal of Prosthetic Dentistry. septembre, vol.100, pp.183-193, 2008.

G. , A. P. , L. T. Borg-k, and . Olsson-m, Tooth-implant and implant supported fixed partial dentures: a 10-year report, The International Journal of Prosthodontics. juin, vol.12, pp.216-221, 1999.

G. Kl, K. Kl, and M. G. Viana, Effect of repeated screw joint closing and opening cycles on implant prosthetic screw reverse torque and implant and screw thread morphology. The Journal of Prosthetic Dentistry. septembre, vol.106, pp.159-169, 2011.

H. Je, . Sakaguchi-rl, C. Sun-t, and . Jp, Elongation and preload stress in dental implant abutment screws. The International Journal of Oral & Maxillofacial Implants, vol.10, pp.529-536, 1995.

M. Haas-r and M. , Brånemark single tooth implants: a preliminary report of 76 implants, The Journal of Prosthetic Dentistry. mars, vol.73, pp.274-279, 1995.

H. Ohashi-n, A new tightening technique for threaded fasteners, Mater Eng ASME. 1992, vol.3, pp.371-377

H. Dm and E. Se, Cyclic loading of implant-supported prostheses: Changes in component fit over time. The Journal of Prosthetic Dentistry, vol.89, pp.346-351, 2003.

H. Dm, E. Se, and . Choi-y-g, Cyclic loading of implant-supported prostheses: Comparison of gaps at the prosthetic-abutment interface when cycled abutments are replaced with as-manufactured abutments, The Journal of Prosthetic Dentistry. janvier, vol.95, issue.1, pp.26-32, 2006.

J. Mj, R. Me, and . Gratton-dg, Comparison of « look-alike » implant prosthetic retaining screws, Journal of Prosthodontics. mars 1995, vol.4, issue.1, pp.23-27

J. Lindén-b, Failures and Complications in 127 Consecutively Placed Fixed Partial Prostheses Supported by Brånemark Implants: From Prosthetic Treatment to First Annual Checkup, International Journal of Oral & Maxillofacial Implants. 1992, vol.7, issue.1, pp.73-82

J. , K. P. Besdo-s, R. M. Stiesch-m, and . Borchers-l, Influence of lubricant on screw preload and stresses in a finite element model for a dental implant, The Journal of Prosthetic Dentistry. août, vol.112, issue.2, pp.340-348, 2014.

J. and J. Carlsson-l, Loads and designs of screw joints for single crowns supported by osseointegrated implants, The International Journal of Oral & Maxillofacial Implants. 1992, vol.7, pp.353-359

K. , Loose Gold Screws Frequently Occur in Full-Arch Fixed Prostheses Supported by Osseointegrated Implants After 5 Years, International Journal of Oral & Maxillofacial Implants. avril 1994, vol.9, issue.2, pp.169-178

K. Jy, R. K. , B. K. , G. Cj, and L. Br, Clinical methods for evaluating implant framework fit. The Journal of Prosthetic Dentistry, vol.81, pp.7-13, 1999.

K. , S. , O. , L. , and A. T. Xps, AES and SEM analysis of recent dental implants, Acta Biomaterialia. juillet 2009, vol.5, pp.2222-2229

K. Ma, W. Rl, and W. Df, In-vitro corrosion and wear of titanium alloys in the biological environment, Biomaterials. novembre, vol.17, pp.2117-2126, 1996.

K. Hashimoto-a and . Nomura-s, Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system, The Journal of Prosthetic Dentistry. avril, vol.91, pp.326-334, 2004.

K. Js, R. Aj, F. Bd, R. Je, C. et al., In vitro assessment of three types of zirconia implant abutments under static load. The Journal of Prosthetic Dentistry, vol.109, pp.255-263, 2013.

K. Sk, K. Jy, H. Sj, T. Td, R. S. et al., Screw loosening with interchangeable abutments in internally connected implants after cyclic loading. The International Journal of Oral & Maxillofacial Implants, vol.27, pp.42-47, 2012.

K. S. , K. , B. Jd, and . Monaco-ea, Comparison of fracture resistance of pressable metal ceramic custom implant abutments with CAD/CAM commercially fabricated zirconia implant abutments. The Journal of Prosthetic Dentistry, vol.101, pp.226-230, 2009.

K. Vanheusden, A. J. , L. E. Goff-so, and M. Ak, Clinical risk factors related to failures with zirconia-based restorations: an up to 9-year retrospective study, Journal of Dentistry. décembre, vol.41, pp.1164-1174, 2013.

K. Vanheusden, A. J. , L. E. Goff-so, and M. Ak, Clinical risk factors related to failures with zirconia-based restorations: An up to 9-year retrospective study, Journal of Dentistry. décembre, vol.41, pp.1164-1174, 2013.

K. Bain-pa and . Levin-l, Systematic review of short-(5-10 years) and longterm (10 years or more) survival and success of full-arch fixed dental hybrid prostheses and supporting implants, Journal of Dentistry. octobre, vol.42, pp.1228-1241, 2014.

L. La, W. Kang-b, and L. Br, Finite element analysis to determine implant preload, The Journal of Prosthetic Dentistry. décembre 2003, vol.90, issue.6, pp.539-546

L. La, M. Kb, and . Wang-r-f, The effect of the use of a counter-torque device on the abutment-implant complex. The Journal of Prosthetic Dentistry, vol.81, pp.411-417, 1999.

L. La, M. Wang-r-f, and . Kb, The influence of abutment screw tightening on screw joint configuration. The Journal of Prosthetic Dentistry, vol.87, pp.74-79, 2002.

L. , J. , K. , K. , and H. , Wave analysis of implant screw loosening using an air cylindrical cyclic loading device. The Journal of Prosthetic Dentistry, vol.88, pp.402-408, 2002.

L. Ma, R. , and M. , Success and complications of implant-retained prostheses provided by the PostDoctoral Prosthodontics Program, University of Puerto Rico: a cross-sectional study, The Journal of Prosthetic Dentistry. novembre, vol.114, issue.5, pp.637-643, 2015.

M. Satoh-t and . Sogo-m, In vitro differences of stress concentrations for internal and external hex implant-abutment connections: a short communication, Journal of Oral Rehabilitation. janvier, vol.33, issue.1, pp.75-78, 2006.

M. Wy, F. Mukherjee-a, and . Lee-py, The economic impact of individually packaged screws. The Surgeon. février, vol.12, pp.35-39, 2014.

M. Wc, W. Rd, M. Bh, and . Miller-aw, Implant abutment screw rotations and preloads for four different screw materials and surfaces, The Journal of Prosthetic Dentistry. juillet, vol.86, issue.1, pp.24-32, 2001.

M. , R. P. , and R. G. , Les implants: chirurgie et prothèse. Paris : Cdp, pp.225-235, 2008.

M. Hja, R. Gm, . Batenburg-rhk, and . Vissink-a, Mandibular overdentures supported by two Brånemark, IMZ or ITI implants: a tenyear prospective randomized study, Journal of Clinical Periodontology. septembre, vol.36, pp.799-806, 2009.

N. Gupta, H. Arora-a, and . Bhandari-a, Biomechanics of implants abutment connection, Indian Journal of Stomatology, vol.2, issue.2, pp.113-116, 2011.

N. Schmage-p and . Shahin-r, Removal of a fractured implant abutment screw: A clinical report, The Journal of Prosthetic Dentistry. juin, 2004.

N. Scheer-m, M. Ra, S. An, K. Ve, Z. Toutenburg-h et al., Precision of fit between implant impression coping and implant replica pairs for three implant systems, NISAND D et RENOUARD F. Implants courts versus greffes osseuses sous sinusiennes : étude clinique retrospective, vol.24, pp.37-43

O. , M. Sr, and C. Cm, Design features that may influence bacterial plaque retention: a retrospective analysis of failed implants, Quintessence International, vol.31, pp.249-256, 1985.

P. Ng and . Hess-dp, Experimental study of loosening of threated fasteners due to dynamic shear loads, Journal of Sound and vibration, p.585, 2002.

P. Boscatto-n, Evaluation of pre tightening in abutments and prosthetic screws on different implant connections, Revista Odonto Ciencia. 2010, vol.25, pp.292-295, 2010.

P. Ea and J. Rb, Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants, The International Journal of Oral & Maxillofacial Implants. 1992, vol.7, issue.1, pp.26-33

P. M. , Comportement biomécanique des prothèses fixées plurales supra-implantaires, Faculté d'odontologie de Nancy, vol.140, p.p, 2006.

P. , W. Wa, M. A. , S. Ss, B. et al., Fatigue resistance of ITI implant-abutment connectors-a comparison of the standard cone with a novel internally keyed design. Clinical Oral Implants Research, vol.13, pp.542-549, 2002.

P. , C. Et, P. Sábio-s, and . Jr,

P. Be, T. D. , J. R. Zwahlen-m, and Z. A. , , vol.110, pp.383-388

P. Benko-y, Caractéristiques de l'ancrage prothétique sur implants : visser ou sceller. Réalités cliniques, vol.13, pp.367-376, 2002.

P. Monaco, J. R. Ea, K. , and D. El, fabricated CAD/CAM zirconia implant abutment, The Journal of Prosthetic Dentistry. novembre 2013, vol.110, issue.5, pp.389-396

R. Br, J. Sullivan-rm, and . Tm, Load factor control for implants in the posterior partially edentulous segment, The International Journal of Oral & Maxillofacial Implants. juin, vol.12, pp.360-370, 1997.

R. , D. E. Mattos-mgc, R. Rcs, and R. Rf, Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study, Clinical Oral Implants Research. juin, vol.20, pp.624-632, 2009.

R. Ej, In vivo vertical forces on implants, The International Journal

, Oral & Maxillofacial Implants. février, vol.10, issue.1, pp.99-108, 1995.

R. , L. H. Loeffel-o, and S. P. ,

. Schweizer-monatsschrift-für-zahnmedizin, , vol.105, pp.611-616, 1995.

R. E. , Making fastened joints reliable...ways to keep'em tight, Assembly Engineering. 1977, vol.3, pp.24-27

R. Neto-dj, C. , D. O. Valle-al, and P. Jr, A method of assessing the effectiveness of the friction fit interface by measuring reverse torque. The Journal of Prosthetic Dentistry, 2014.

R. , Biocompatibilité des implants dentaires. Réalités cliniques, vol.16, pp.187-195, 2005.

R. Picard-b, Comprehension des phénomènes de dévissage en prothèse implantaire. Quelles peuvent être les causes de dévissage d'une prothèse implanto portée. Le chirurgien dentiste de France, vol.69, pp.29-40, 1999.

?. , Ç. Mc, and Y. , The influence of functional forces on the biomechanics of implant-supported prostheses-a review, Journal of Dentistry. septembre, vol.30, pp.271-282, 2002.

S. , A. Kadir-mr, S. E. , and A. Kasim-nh, Effects of different implant-abutment connections on micromotion and stress distribution: Prediction of microgap formation, Journal of Dentistry. juin, vol.40, pp.467-474, 2012.

S. Mühlemann-s, Z. M. , H. Chf, and . Schneider-d, Cemented and screw-retained implant reconstructions: a systematic review of the survival and complication rates, Clinical Oral Implants Research. octobre, vol.23, issue.6, pp.163-201, 2012.

B. Sakaguchi-rl and . Se, Nonlinear contact analysis of preload in dental implant screws, The International Journal of Oral & Maxillofacial Implants. juin 1995, vol.10, pp.295-302

. Salinas-t and . Eckert-s, Implant-supported single crowns predictably survive to five years with limited complications. The Journal of Evidence-Based Dental Practice. septembre, vol.12, pp.213-214, 2012.

. Schwartz-ms, Mechanical complications of dental implants, Clinical Oral Implants Research, vol.11, pp.58-64, 2000.

S. Kraft-s and K. T. Nelson-k, Theoretical considerations: implant positional index design, Journal of Dental Research. août 2009, vol.88, pp.725-730

S. Heberer-s, M. J. Schink-t, and . Nelson-k, Effects of repeated manual disassembly and reassembly on the positional stability of various implant-abutment complexes: an experimental study, The International Journal of Oral & Maxillofacial Implants. février, vol.25, issue.1, pp.86-94, 2010.

S. Bf, Wear and corrosion of sliding counterparts of stainless-steel hip screw-plates, Injury. mars, vol.31, issue.2, pp.85-92, 2000.

. Shao-xy and D. Et, On the mechanical integrity of retrieved dental implants, International Conference on Manufacturing Automation: Advanced Design and Manufacturing in Global Competition, vol.135, pp.290-299, 2005.

S. Je, M. Cr, B. Squier-rs, P. Wj, and T. Td, Removal torques of conical, tapered implant abutments: the effects of anodization and reduction of surface area, The International Journal of Oral & Maxillofacial Implants. février, vol.212, issue.137, pp.24-27, 2002.

S. , W. S. , and L. K. Kern-m, Implantabutment interface design affects fatigue and fracture strength of implants, Clinical Oral Implants Research. décembre, vol.19, pp.1276-1284, 2008.

S. , E. D. , G. , E. K. Happe-a, and . Beuer-f, Wear at the titanium-titanium and the titanium-zirconia implant-abutment interface: A comparative in vitro study, Dental Materials. décembre, vol.28, pp.1215-1220, 2012.

S. , W. Hp, B. Sorensen-j, and . Uc, The new restorative concept of the ITI dental implant system : design and engineering, International Journal of Periodont, vol.13, p.31, 1993.

T. Kb and N. Ji, The Effect of 3 Torque Delivery Systems on Gold Screw Preload at the Gold Cylinder-Abutment Screw Joint, International Journal of Oral & Maxillofacial Implants. avril, vol.17, issue.2, pp.175-183, 2002.

T. Kokubo-y, . Kano-t, and . Sasaki-k, The effect of fatigue loading on the screw joint stability of zirconium abutment, Journal of Prosthodontic Research. juillet 2013, vol.57, pp.219-223

T. Gk, N. Ww, F. Ra, D. Vb, . Vianna-ca et al., The effect of repeated torque and salivary contamination on the preload of slotted gold implant prosthetic screws. The Journal of Prosthetic Dentistry, The International Journal of Oral & Maxillofacial Implants. octobre 2013, vol.88, issue.2, pp.209-214, 2002.

V. Schittly-j, Comparaison de la stabilité en rotation des différents dispositifs antirotationnels, Implants, vol.4, pp.201-211, 1998.

W. N. , Les différents types de connexions implantaires : description, avantages, inconvenients et critères de choix, p.132, 2013.

W. P. , Le plan de traitement et les 8 critères occlusaux de reconstruction (OCTA).Synergie prothétique, vol.3, p.20, 2001.

W. Ei, G. Kozak-d, and . Md, Effect of repeated closures on opening torque values in seven abutment-implant systems, The Journal of Prosthetic Dentistry. août, vol.84, issue.2, pp.194-199, 2000.

W. Dn, The Hydrogen embrittlement of titanium alloys, Journal Inst Metals. 1962, vol.147, p.52

Z. Weigl-p and . Lange-b, Micromovments at the Implants-Abutment interface, Implantologie, vol.15, issue.1, pp.31-46, 2007.

, Critères de choix d'un pilier implantaire en prothèse fixée, Références bibliographiques électroniques : 151. COURTIN N, 2012.

C. Analyse and . Gmbh, Microscopie à balayage MEB et microanalyse par rayons X EDX, Disponible à l'adresse

. Dentsply-implants and . System, Manuel des restaurations transvissées, procédures cliniques et de laboratoires

D. ,

, DENTSPLY Implants System. Manuel des restaurations prothétiques scéllées

D. ,

, PLY%20Implants%20version.ashx?filetype=.pdf

D. Jh, D. Mt, . Goudot-p.-réhabilitation-orale, and . Implantologie, , 2000.

. Disponible,

F. Sciences-magazine, Microscope confocal à balayage laser

. Disponible,

G. , B. Ma, and G. Jj, Evaluation de la biocompatibilité des dispositifs médicaux utilisés en odontologie, 2011.

K. D. , Le titane et ses alliages

D. ,

L. , Titane et alliages, des matériaux de choix pour les applications médicales, vol.10

. Disponible,

P. Garnero-l and . Magnin-i, Introduction à l'imagerie tomographique 2D et 3 D reposant sur une propagation en ligne droite. Cas de la tomographie par rayon X, par émission et par ultrasons, vol.13, 1996.

D. ,

R. B. , Etats de Surface, 2008.

. Disponible,

S. and M. , , 2012.

, Disponible à l'adresse : www.swedenmartina

T. and L. , Information Dentaire. La connexion implantaire interne ou externe, vol.88, 2006.

W. and G. , Technologie des implants ostéointégrés, Cdp, 1994.

Z. and M. Mécaniques, La mesure de rugosité ? Quelques normes...et plusieurs dizaines de paramètres, vol.758, pp.59-63, 2003.

Z. Lsm, 700 Votre microscope confocal compact à balayage laser

. Disponible,

. , 1 Considérations actuelles et description des connexions implantaires

. , Généralités sur les restaurations prothétiques implantaires fixées

:. .. Prothèse-implanto-portée-transvisée,

:. .. Prothèse-implanto-portée-scellée,

:. .. Complexe-implant-pilier-vis,

:. .. Implants,

. , 2.1.3 Formes principales d'implants : (cf figure2), .1.2 Propriétés physiques et mécaniques du titane

. , Col implantaire : (cf figure 3)

:. .. Diamètre-implantaire,

:. .. Conicité-implantaire,

:. .. Pas-de-vis-implantaire,

. , Cahier des charges d'un pilier implantaire

. .. , Types de piliers implantaires en fonction de leur procédé de fabrication, p.45

. , Cahier des charges d'une vis implantaire

:. .. Connexions-implanto-prothétiques,

:. .. Connexions,

:. .. Connexions,

. , Cahier des charges d'une connexion implantaire

, Comparaison des différents types de connexions implantaires, p.55

:. .. Vissage-du-complexe-implanto-prothétique,

:. .. Principe,

:. .. Précontrainte,

:. .. Facteurs-influençant-la-précontrainte,

:. .. Couple-de-serrage,

. , Défauts d'adaptation entre les pièces

:. .. Longueur-de-la-vis,

:. .. ,

:. .. Dévissage,

:. .. Echecs-en-prothèse-implantaire,

:. .. Mécanisme-du-dévissage,

:. .. Diagnostique-du-dévissage,

:. .. Causes-du-dévissage,

. , 5.5.9 Technique de conception des pièces implantaires, vol.5, p.10

. .. Effet-«-settling-»-:,

:. .. Couple,

:. .. Fermeture,

:. .. Conséquences-du-dévissage,

:. .. Eléments-pour-contrer-le-dévissage,

:. .. Objectifs-de-l'étude,

:. .. Hypothèses,

:. .. Implants,

:. .. Protocole-opératoire-de-l'étude,

. , Protocole de désinfection des pièces implantaires

:. .. Microscopie-optique,

. , Zones observées au Microscope Optique sur les implants

. , Zones observées au Microscope Optique sur les piliers implantaires

. , Zones observées au Microscope Optique sur les vis implantaires

. .. , Zones observées au Microscope Electronique à Balayage sur les implants, p.113

, Zones observées au Microscope Electronique à Balayage sur les piliers implantaires

, Zones observées au Microscope Electronique à Balayage sur les vis implantaires, p.115

:. .. Analyse-dispersive-en-Énergie,

:. .. Analyse-de-l'état-de-surface,

. , Technique d'analyse employée dans l'étude

A. Au-microscope-optique and :. .. ,

:. .. Analyse-de-l'état-de-surface,

. , Analyse

:. .. Résultats,

A. Au-microscope-optique and :. .. ,

. , Observation des implants 1 et 2 : (cf tableau 25 et 26)

. , Observation des piliers 1 et 2 : (cf tableau 27 et 28)

A. Au-microscope-electronique-À-balayage and :. .. ,

. , Observation des implants 1 et 2 : (cf tableau 29 et 30)

. , Observations des piliers 1 et 2 : (cf tableau 31 et 32)

. , et 36), vol.34, p.35

:. .. Analyse-de-l'état-de-surface,

. .. Analyse-tomographique-À-rayons-x-:,

. , Analyse

. , Analyse des coupes zx et zy

. .. Discussion, 173 4.1 Influence des cycles de serrage/ desserrage sur les surfaces des éléments du complexe implant-pilier-vis

:. .. Présence-de-défauts-d'usinage,

:. .. Traces-d'usures,

. , Influence des cycles sur le coefficient de friction et la rugosité des surfaces

:. .. Etude-de-la-rugosité,

. , Influence des cycles sur le repositionnement des pièces implantaires

, Influence des cycles de serrage/desserrage sur le couple de desserrage et la précontrainte

:. .. Limites-/-perspectives,

. .. Conclusion,

:. .. Bibliographie,