Mechanical property assessment of bone healing around a titanium-zirconium alloy dental implant, Clin Implant Dent Relat Res, vol.16, issue.6, pp.913-919, 2014. ,
Retrospective study of short and extra-short implants placed in posterior regions: influence of crown-to implant ratio on marginal bone loss, Clin Implant Dent Relat Res, vol.17, issue.1, pp.102-110, 2015. ,
Implant survival and crestal bone loss around extra-short implants supporting a fixed denture: The effect of crown height space, crown-to-implant ratio, and offset placement of the prosthesis, Int J Oral Maxillofacial Implants, vol.29, issue.3, pp.682-689, 2014. ,
Une observation anatomo-clinique, Rev Mens Suisse Odontostomatol, vol.123, issue.3, pp.216-225, 2013. ,
Can resonance frequency analysis predict failure risk of immediately loaded implants?, Int J Prosthodont, vol.25, issue.4, 2012. ,
Survival of short dental implants for treatment of posterior partial edentulism: A systematic review, Int J Oral Maxillofacial Implants, vol.27, issue.6, pp.1323-1331, 2012. ,
Methods used to assess implant stability: current status, Int J Oral Maxillofacial Implants, vol.22, issue.5, pp.743-754, 2007. ,
Osteoblastic and osteoclastic differentiation on SLA and hydrophilic modified SLA titanium surfaces ,
, Clin Oral Implants Res, vol.25, issue.7, pp.831-837, 2014.
Les protocoles de forage. Le fil dentaire. 2010 févr, pp.10-12 ,
,
, Examen et deux rapports de cas. Implants, vol.1, pp.10-13, 2012.
Evaluation of extrashort 4mm implants in mandibular edentulous patients with reduced bone height in comparison with standard implants: A 12-month results, Clin Oral Implants Res, vol.00, pp.1-8, 2015. ,
,
Manuel d'implantologie clinique. Concepts, intégration des protocoles et esquisse de nouveaux paradigmes. 3 e édition. Rueil-Malmaison : Éditions CdP, vol.656, 2012. ,
,
,
A 3-year post-loading report of a randomised controlled trial on the rehabilitation of posterior atrophic mandibles: short implants or longer implants in vertically augmented bone?, Eur J Oral Implantol, vol.4, issue.4, pp.301-311, 2011. ,
Posterior jaws rehabilitated with partial prostheses supported by 4.0 x 4.0 mm or by longer implants: One-year post-loading results from a multicenter randomised controlled trial, Eur J Oral Implantol, vol.9, issue.1, pp.35-45, 2016. ,
La prothèse amovible partielle stabilisée sur implants ,
Evaluation of a new titanium-zirconium dental implant: A biomechanical and histological comparative study in the mini pig, Clin Implant Dent Relat Res, vol.14, issue.4, pp.538-545, 2012. ,
A review of titanium zirconium (TiZr) alloys for use in endosseous dental implants, Materials, vol.5, pp.1348-1360, 2012. ,
Implants of 6 mm vs. 11 mm lengths in the posterior maxilla and mandible: A 1-year multicenter randomized controlled trial, Clin Oral Implants Res, vol.24, issue.12, pp.1325-1331, 2013. ,
Vertical osteoconductivity and early bone formation of titanium-zirconium and titanium implants in a subperiosteal rabbit animal model, Clin Oral Implants Res, vol.25, issue.7, pp.774-780, 2014. ,
Les implants courts [mémoire pour le DU d'implantologie chirurgicale orale et maxillo-faciale ,
A systematic review and meta-analysis on the effect of implant length on the survival of roughsurface dental implants, J Periodontol, vol.80, issue.11, pp.1700-1718, 2009. ,
Long-term outcomes of short dental implants supporting single crowns in posterior region: A clinical retrospective study of 5-10 years, Clin Oral Impl Res, vol.24, issue.2, pp.230-237, 2013. ,
Retrospective multicenter study of 230 6-mm SLA-surfaced implants with 1-to 6-year follow-up, Int J Oral Maxillofacial Implants, vol.28, issue.5, pp.1331-1337, 2013. ,
Six-mm versus 10-mm long implants in the rehabilitation of posterior edentulous jaws: A 5year follow-up of a randomised controlled trial, Eur J Oral Implantol, vol.7, issue.4, pp.371-381, 2014. ,
Early loading of single crowns supported by 6-mm-long implants with a moderately rough surface: a prospective 2-year follow-up cohort study, Clin Oral Impl Res, vol.21, issue.9, pp.937-943, 2010. ,
Enhancing surface free energy and hydrophilicity through chemical modification of microstructured titanium implant surfaces, J Biomed Mater Res A, vol.76, issue.2, pp.323-334, 2006. ,
Résorptions osseuses importantes des régions postérieures maxillaires : implants courts ou thérapeutiques d'aménagement de la zone soussinusienne ? Comparaison suivi et résultats ,
Place croissante des implants courts et ultracourts dans la thérapeutique implantaire, Implant, vol.19, pp.171-179, 2013. ,
Effects of surface hydrophilicity and microtopography on early stages of soft and hard tissue integration at non-submerged titanium implants: An immunohistochemical study in dogs, J Periodontol, vol.78, issue.11, pp.2171-2184, 2007. ,
Fourmillimeter implants supporting fixed partial dental prostheses in the severely resorbed posterior mandible : Two-year results, Clin Implant Dent Relat Res, vol.14, pp.46-58, 2012. ,
Four-millimeter-long posteriormandible implants: 5-year outcomes of a prospective multicenter study, Clin Implant Dent Relat Res, vol.17, pp.385-95, 2015. ,
The effect of the ,
Analyse métallurgique : micrographies des structures, examen de la géométrie et des surfaces au microscope électronique à balayage, microduretés,? Et viabilité cellulaire. Implantologie revue trimestrielle, vol.8, pp.141-149, 2010. ,
,
Implant micromotion is related to peak insertion torque and bone density, Clin Oral Impl Res, vol.20, issue.5, pp.467-471, 2009. ,
The survival of ultrashort locking-taper implants, Int J Oral Maxillofac Implants, 2012. ,
Analysis of the influence of implant shape on primary stability using the correlation of multiple methods, Clin Oral Investig, vol.19, issue.8, pp.1861-1866, 2015. ,
The osseointegration behavior of titanium-zirconium implants in ovariectomized rabbits, Clin Oral Implants Res, vol.25, issue.7, pp.819-825, 2014. ,
,
Rehabilitation of an atrophic posterior mandible with 4-mm short implants: A 3-year post-loading case report, 2015. ,
,
,
,
,
,
,
,
SLActive® preuves scientifiques cinquième ,
,
De nouvelles normes en matière de qualité de l'ostéointégration-Les implants titane-zirconium ,
,
Implant court Straumann® Standard Plus. Plus qu'un implant court. Un nouveau monde de possibilités, 2014. ,
,
Mode d'emploi : Implants dentaires Straumann® : Roxolid® Standard Plus implant court de 4mm, 2014. ,
Plus qu'une surface d'implant unique ,
, L'optimisation du succès et de la prédictibilité du traitement, 2014.
Plus que résistant-Roxolid®, 2014. ,
,
,
,
,
,
,
, OMS. 10 faits sur le diabète, 2016.
,
,
,
,
,
,
,
,
21 1. Caractéristiques générales de l'implant améliorant l'ostéointégration, Chapitre, vol.1 ,
, Description de l'implant ultracourt Straumann® Standard Plus
,
Alliage de titane et surface sablée mordancée SA² ,
Tableau comparatif des implants de quatre millimètres ,
, Chapitre, vol.2
Proximité avec le canal mandibulaire et le foramen mentonnier ,
,
, Traitements des implants ultracourts de quatre millimètres
Synthèse de l'usage prévu pour les implants de quatre millimètres ,
, Chapitre, vol.3
2.3. Solidarisation rigide et passive des implants par l'armature prothétique ,
65 3.2. Etudes utilisant des implants de quatre millimètres ,
Synthèse des études utilisant les implants de quatre millimètres ,
,
,
,