C. G. Adorno, G. Carlos, Y. Takatomo, and S. Et-hideaki, « Crack Initiation on the Apical Root Surface Caused by Three Different Nickel-Titanium Rotary Files at Different Working Lengths, ResearchGate, vol.37, issue.4, pp.522-547, 2011.

G. Alexandrou, K. Chrissafis, L. Vasiliadis, E. Pavlidou, and E. K. Et-polychroniadis, Effect of Heat Sterilization on Surface Characteristics and Microstructure of Mani NRT Rotary Nickel-titanium Instruments, vol.39, pp.770-78, 2006.

A. P. Alves-claro, F. A. Claro, and E. T. Et-uzumaki, « Wear Resistance of Nickel-Titanium Endodontic Files after Surface Treatment », Journal of Materials Science. Materials in Medicine, vol.19, issue.10, pp.3273-77, 2008.

G. Ametrano, V. D'antò, D. Caprio, M. P. Simeone, M. Rengo et al., « Effects of Sodium Hypochlorite and Ethylenediaminetetraacetic Acid on Rotary Nickel-titanium Instruments Evaluated Using Atomic Force Microscopy, International Endodontic Journal, vol.44, issue.3, pp.203-212, 2011.

M. E. Anderson, J. W. Price, and P. Et-parashos, « Fracture Resistance of Electropolished Rotary Nickel-Titanium Endodontic Instruments, Journal of Endodontics, vol.33, issue.10, pp.1212-1228, 2007.

M. G. Bahia and V. T. Et-buono, « Decrease in the fatigue resistance of nickeltitanium rotary instruments after clinical use in curved root canals ». Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology, vol.100, pp.249-55, 2005.

F. Barbakow and F. Et-lutz, « The "Lightspeed" Preparation Technique Evaluated by Swiss Clinicians after Attending Continuing Education Courses, International Endodontic Journal, vol.30, issue.1, pp.46-50, 1997.

F. O. Barbosa, J. A. Gomes, and M. C. Et-de-araújo, Influence of Electrochemical Polishing on the Mechanical Properties of K3 Nickel-Titanium Rotary Instruments, vol.34, pp.1533-1569, 2008.

M. P. Baron, « Etude du comportement des interfaces austénite/martensite et martensite/martensite de deux alliages à mémoire de forme le CuZnAl et le CuAlBe, 1998.

L. Bataillard, « Transformation martensitique multiple d'un alliage à mémoire de fome NiTi, 1996.

M. A. Baumann and A. Et-roth, « Effect of experience on quality of canal preparation with rotary nickel-titanium files ». Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology, vol.88, issue.6, pp.70015-70021, 1999.

L. Bergmans, J. Van-cleynenbreugel, M. Beullens, M. Wevers, B. Van-meerbeek et al., « Progressive versus Constant Tapered Shaft Design Using NiTi Rotary Instruments, International Endodontic Journal, vol.36, issue.4, pp.288-95, 2003.

E. Berutti, G. Chiandussi, I. Gaviglio, and A. Et-ibba, « Comparative Analysis of Torsional and Bending Stresses in Two Mathematical Models of NickelTitanium Rotary Instruments: ProTaper versus ProFile », Journal of Endodontics, vol.29, issue.1, pp.15-24, 2003.

K. Bishop and P. M. Et-dummer, « A Comparison of Stainless Steel Flexofiles and Nickel-Titanium NiTiFlex Files during the Shaping of Simulated Canals, International Endodontic Journal, vol.30, issue.1, pp.25-34, 1997.

J. Y. Blum, A. Cohen, P. Machtou, and J. P. Et-micallef, « Analysis of Forces Developed during Mechanical Preparation of Extracted Teeth Using Profile NiTi Rotary Instruments, International Endodontic Journal, vol.32, issue.1, pp.24-31, 1999.

J. Y. Blum, P. Machtou, and J. P. Et-micallef, « Location Of Contact Areas On Rotary Profile Instruments In Relationship To The Forces Developed During Mechanical Preparation On Extracted Teeth, ResearchGate, vol.32, issue.2, pp.108-122, 1999.

C. Boessler, F. Paque, and O. A. Et-peters, « The Effect of Electropolishing on Torque and Force during Simulated Root Canal Preparation with ProTaper Shaping Files, Journal of Endodontics, vol.35, issue.1, pp.102-108, 2009.

J. S. Bowles and J. K. Et-mackenzie, « The crystallography of martensite transformations II, Acta Metallurgica, vol.2, issue.1, pp.90102-90111, 1954.

B. Bui-tung, J. C. Mitchell, and J. C. Baumgartner, Effect of Electropolishing ProFile Nickel-Titanium Rotary Instruments on Cyclic Fatigue Resistance, Torsional Resistance, and Cutting Efficiency, vol.34, pp.190-93, 2008.

S. Bürklein, S. Benten, and E. Et-schäfer, « Shaping Ability of Different Single-File Systems in Severely Curved Root Canals of Extracted Teeth, International Endodontic Journal, vol.46, issue.6, pp.590-97, 2013.

S. Bürklein, D. Mathey, and E. Et-schäfer, « Shaping Ability of ProTaper NEXT and BT-RaCe Nickel-titanium Instruments in Severely Curved Root Canals, International Endodontic Journal, vol.48, issue.8, pp.774-81, 2015.

A. Byström and G. Et-sundqvist, « Bacteriologic evaluation of the effect of 0.5 percent sodium hypochlorite in endodontic therapy ». Oral Surgery, Oral Medicine, Oral Pathology, vol.55, issue.3, pp.307-319, 1983.

J. J. Camps and W. J. Et-pertot, Relationship between File Size and Stiffness of Stainless Steel Instruments, vol.10, pp.260-263, 1994.

J. J. Camps, W. J. Pertot, and B. Et-levallois, Relationship between File Size and Stiffness of Nickel Titanium Instruments, vol.11, pp.270-273, 1995.

L. S. Castleman, S. M. Motzkin, F. P. Alicandri, and V. L. Et-bonawit, « Biocompatibility of Nitinol Alloy as an Implant Material, Journal of Biomedical Materials Research, vol.10, issue.5, pp.695-731, 1976.

M. Chaves-craveiro-de-melo, . Guiomar-de-azevedo, M. Bahia, and V. T. Et-lopes-buono, « Fatigue Resistance of Engine-Driven Rotary Nickel-Titanium Endodontic Instruments, Journal of Endodontics, vol.28, issue.11, pp.765-774, 2002.

G. S. Cheung and B. W. Et-darvell, « Fatigue Testing of a NiTi Rotary Instrument. Part 1: Strain-life Relationship, International Endodontic Journal, vol.40, issue.8, pp.612-620, 2007.

G. S. Cheung and B. W. Et-darvell, « Fatigue Testing of a NiTi Rotary Instrument. Part 2: Fractographic Analysis, International Endodontic Journal, vol.40, issue.8, pp.619-644, 2007.

G. S. Cheung and B. W. Et-darvell, « Low-Cycle Fatigue of NiTi Rotary Instruments of Various Cross-Sectional Shapes, International Endodontic Journal, vol.40, issue.8, pp.626-658, 2007.

G. S. Cheung, B. Peng, Z. Bian, Y. Shen, and B. W. Et-darvell, « Defects in ProTaper S1 Instruments after Clinical Use: Fractographic Examination, International Endodontic Journal, vol.38, issue.11, pp.802-811, 2005.

G. G. Condorelli, A. Bonaccorso, E. Smecca, E. Schäfer, G. Cantatore et al., « Improvement of the Fatigue Resistance of NiTi Endodontic Files by Surface and Bulk Modifications, International Endodontic Journal, vol.43, issue.10, pp.866-73, 2010.

M. Darabara, L. Bourithis, S. Zinelis, and G. D. Et-papadimitriou, « Susceptibility to Localized Corrosion of Stainless Steel and NiTi Endodontic Instruments in Irrigating Solutions, International Endodontic Journal, vol.37, issue.10, pp.705-715, 2004.

G. De-deus, M. C. Brandão, B. Barino, D. Giorgi, K. Fidel et al., « Assessment of apically extruded debris produced by the single-file ProTaper F2 technique under reciprocating movement ». Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology, vol.110, issue.3, pp.390-394, 2010.

D. Fiore, P. M. Genov, K. I. Komaroff, E. Dasanayake, A. P. Et-lin et al., « Fracture of ProFile Nickel-titanium Rotary Instruments: A Laboratory Simulation Assessment, International Endodontic Journal, vol.39, issue.6, pp.502-511, 2006.

F. Diemer and P. Et-calas, « Effect of Pitch Length on the Behavior of Rotary Triple Helix Root Canal Instruments », Journal of Endodontics, vol.30, issue.10, pp.716-724, 2004.

A. Duval, « Modélisation du comportement thermomécanique d'alliages à mémoire de forme. Application au dimensionnement de microsystèmes et extension en non local, p.146, 2009.

A. M. Elnaghy, « Cyclic Fatigue Resistance of ProTaper Next Nickel-Titanium Rotary Files, International Endodontic Journal, vol.47, issue.11, pp.1034-1043, 2014.

D. Entemeyer, E. Patoor, A. Eberhardt, and M. Et-berveiller, « Strain rate sensitivity in superelasticity, International Journal of Plasticity, vol.16, issue.10-11, pp.1269-88, 2000.

P. T. Esposito and C. J. Et-cunningham, « A comparison of canal preparation with nickel-titanium and stainless steel instruments, Journal of Endodontics, vol.21, issue.4, pp.80560-80561, 1995.

G. Faúndez, M. Troncoso, P. Navarrete, and G. Et-figueroa, « Antimicrobial activity of copper surfaces against suspensions of Salmonella enterica and Campylobacter jejuni, BMC Microbiology, vol.4, p.19, 2004.

G. Gambarini, « Cyclic Fatigue of ProFile Rotary Instruments after Prolonged Clinical Use, International Endodontic Journal, vol.34, issue.5, pp.386-89, 2001.

G. Gambarini, R. Gerosa, M. De-luca, M. Garala, and L. Et-testarelli, « Mechanical Properties of a New and Improved Nickel-Titanium Alloy for Endodontic Use: An Evaluation of File Flexibility ». Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontics, vol.105, issue.6, pp.798-800, 2008.

G. Gambarini, G. Pompa, D. Carlo, S. De-luca, M. Et-testarelli et al., An Initial Investigation on Torsional Properties of Nickel-Titanium Instruments Produced with a New Manufacturing Method, vol.35, pp.70-72, 2009.

L. F. Garcia, E. C. Sponchiado, D. A. Meireles, A. A. Marques, and A. D. Et-garrido, « Assessment of Apical Deviation of Root Canals after Debridement with the Hybrid, ProTaper and PathFile Systems », Journal of Interdisciplinary Dentistry, vol.2, issue.1, p.20, 2012.

G. Gavini, O. F. Pessoa, F. B. Barletta, M. A. Vasconcellos, and C. L. Et-caldeira, « Cyclic Fatigue Resistance of Rotary Nickel-Titanium Instruments Submitted to Nitrogen Ion Implantation, Journal of Endodontics, vol.36, issue.7, pp.1183-1189, 2010.

R. Gergi, J. A. Rjeily, J. Sader, and A. Et-naaman, « Comparison of Canal Transportation and Centering Ability of Twisted Files, Pathfile-ProTaper System, and Stainless Steel Hand K-Files by Using Computed Tomography », Journal of Endodontics, vol.36, issue.5, pp.904-911, 2010.

C. R. Glosson, R. H. Haller, S. B. Dove, and C. E. Et-del-rio, « A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments, Journal of Endodontics, vol.21, issue.3, pp.80441-80444, 1995.

N. M. Grande, G. Plotino, R. Pecci, R. Bedini, V. A. Malagnino et al., « Cyclic Fatigue Resistance and Three-Dimensional Analysis of Instruments from Two Nickel-titanium Rotary Systems, International Endodontic Journal, vol.39, issue.10, pp.755-63, 2006.
DOI : 10.1111/j.1365-2591.2006.01143.x

G. Grass, C. Rensing, and M. Et-solioz, Metallic Copper as an Antimicrobial Surface, Applied and Environmental Microbiology, vol.77, issue.5, pp.1541-1548, 2011.
DOI : 10.1128/aem.02766-10

URL : https://aem.asm.org/content/77/5/1541.full.pdf

I. T. Griffiths, A. L. Chassot, M. F. Nascimento, S. T. Bryant, and P. M. Et-dummer, « Canal Shapes Produced Sequentially during Instrumentation with Quantec SC Rotary Nickel-titanium Instruments: A Study in Simulated Canals, International Endodontic Journal, vol.34, issue.2, pp.107-119, 2001.

J. H. Gutiérrez, A. Jofré, and F. Et-villena, « Scanning electron microscope study on the action of endodontic irrigants on bacteria invading the dentinal tubules ». Oral Surgery, Oral Medicine, Oral Pathology, vol.69, issue.4, pp.90385-90391, 1990.

J. L. Gutmann and Y. Et-gao, « Alteration in the Inherent Metallic and Surface Properties of Nickel-titanium Root Canal Instruments to Enhance Performance, Durability and Safety: A Focused Review, International Endodontic Journal, vol.45, issue.2, pp.113-141, 2012.

J. H. Ha, G. S. Cheung, A. Versluis, C. J. Lee, S. W. Kwak et al., « 'Screw-In' Tendency of Rotary Nickel-titanium Files due to Design Geometry, International Endodontic Journal, vol.48, issue.7, pp.666-72, 2015.

J. H. Ha and S. S. Et-park, « Influence of Glide Path on the Screw-in Effect and Torque of Nickel-Titanium Rotary Files in Simulated Resin Root Canals, Restorative Dentistry & Endodontics, vol.37, issue.4, pp.215-224, 2012.

Y. Haïkel, R. Serfaty, G. Bateman, B. Senger, and C. Et-allemann, « Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments, Journal of Endodontics, vol.25, issue.6, pp.434-474, 1999.

H. Hamanaka, T. Yoneyama, H. Doi, Y. Okamoto, M. Mogi et al., « [Mechanical properties and phase transformation of super-elastic Ni-Ti alloy wires, Shika Zairyo, Kikai = Journal of the Japanese Society for Dental Materials and Devices, vol.8, issue.2, pp.216-239, 1989.

P. B. Hilfer, B. E. Bergeron, M. J. Mayerchak, H. W. Roberts, and B. G. Et-jeansonne, Multiple Autoclave Cycle Effects on Cyclic Fatigue of Nickel-Titanium Rotary Files Produced by New Manufacturing Methods », vol.37, pp.72-76, 2011.

M. Hülsmann, M. Schade, and F. Et-schäfers, « A Comparative Study of Root Canal Preparation with HERO 642 and Quantec SC Rotary Ni-Ti Instruments, International Endodontic Journal, vol.34, issue.7, pp.538-584, 2001.

M. Hülsmann, O. A. Peters, and P. M. Et-dummer, Mechanical Preparation of Root Canals: Shaping Goals, Techniques and Means, vol.10, pp.30-76, 2005.

R. B. Kazemi, E. Stenman, and L. S. Et-spångberg, « A comparison of stainless steel and nickel-titanium H-type instruments of identical design: Torsional and bending tests ». Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology, vol.90, issue.4, pp.500-506, 2000.

K. Kerekes and L. Et-tronstad, « Long-term results of endodontic treatment performed with a standardized technique, Journal of Endodontics, vol.5, issue.3, pp.80154-80159, 1979.

H. C. Kim, H. J. Kim, C. J. Lee, B. M. Kim, J. K. Park et al., « Mechanical Response of Nickel-titanium Instruments with Different Cross-Sectional Designs during Shaping of Simulated Curved Canals, International Endodontic Journal, vol.42, issue.7, pp.593-602, 2009.

T. O. Kim, G. S. Cheung, J. M. Lee, B. M. Kim, B. Hur et al., « Stress Distribution of Three NiTi Rotary Files under Bending and Torsional Conditions Using a Mathematic Analysis, International Endodontic Journal, vol.42, issue.1, pp.14-21, 2009.

E. Kosti, S. Zinelis, I. Molyvdas, and T. Et-lambrianidis, « Effect of Root Canal Curvature on the Failure Incidence of ProFile Rotary Ni-Ti Endodontic Instruments, International Endodontic Journal, vol.44, issue.10, pp.917-942, 2011.

G. Kuhn and L. Et-jordan, « Fatigue and Mechanical Properties of Nickel-Titanium Endodontic Instruments, Journal of Endodontics, vol.28, issue.10, pp.716-736, 2002.

J. M. Laurichesse, F. Maestroni, J. Breillat, L. J. Baume, and S. Et-hospice, Endodontie clinique, 1986.

D. H. Lee, B. Park, A. Saxena, and T. P. Et-serene, « Enhanced surface hardness by boron implantation in nitinol alloy, Journal of Endodontics, vol.22, issue.10, pp.543-549, 1996.

R. M. Love, « Regional variation in root dentinal tubule infection by Streptococcus gordonii, Journal of Endodontics, vol.22, issue.6, pp.80261-80266, 1996.

J. Luo, C. Hein, F. Mücklich, and M. Et-solioz, « Killing of Bacteria by Copper, Cadmium, and Silver Surfaces Reveals Relevant Physicochemical Parameters, Biointerphases, vol.12, issue.2, p.20301, 2017.

A. A. Madarati, D. C. Watts, and A. J. Et-qualtrough, « Opinions and Attitudes of Endodontists and General Dental Practitioners in the UK towards the Intracanal Fracture of Endodontic Instruments: Part 1, International Endodontic Journal, vol.41, issue.8, pp.693-701, 2008.

E. Mandel, M. Adib-yazdi, L. M. Benhamou, T. Lachkar, C. Mesgouez et al., « Rotary Ni-Ti Profile Systems for Preparing Curved Canals in Resin Blocks: Influence of Operator on Instrument Breakage, International Endodontic Journal, vol.32, issue.6, pp.436-479, 1999.

V. Marmotte, Apport de la rotation continue en endodontie ». Diplôme d'état de docteur en chirurgie dentaire, 2000.
URL : https://hal.archives-ouvertes.fr/hal-01739076

T. C. Matheus, W. M. Menezes, O. D. Rigo, L. K. Kabayama, C. S. Viana et al., « The Influence of Carbon Content on Cyclic Fatigue of NiTi SMA Wires, International Endodontic Journal, vol.44, issue.6, pp.567-73, 2011.

T. Matsuo, T. Shirakami, K. Ozaki, T. Nakanishi, H. Yumoto et al., « An Immunohistological Study of the Localization of Bacteria Invading Root Pulpal Walls of Teeth with Periapical Lesions », Journal of Endodontics, vol.29, issue.3, pp.194-200, 2003.

A. Maynadier, « Couplages thermomécaniques dans les alliages à mémoire de forme : mesure de champs cinématique et thermique et modélisation multiéchelle, 2012.

A. Medha, S. Patil, U. Hoshing, and S. Et-bandekar, « Evaluation of Forces Generated on Three Different Rotary File Systems in Apical Third of Root Canal using Finite Element Analysis, Journal of Clinical and Diagnostic Research : JCDR, vol.8, issue.1, pp.243-289, 2014.

. Micro-méga® and . Mm-endobook, Internet] J.C. Augé, 2012.

K. Miyai, A. Ebihara, Y. Hayashi, H. Doi, H. Suda et al., « Influence of Phase Transformation on the Torsional and Bending Properties of Nickeltitanium Rotary Endodontic Instruments, International Endodontic Journal, vol.39, issue.2, pp.119-145, 2006.

S. Miyazaki, Y. Ohmi, K. Otsuka, and Y. Suzuki, « Characteristics of deformation and transformation pseudoelasticity in Ti-Ni alloys », Journal de Physique Colloques, vol.43, issue.C4, 1982.

S. Necchi, S. Taschieri, L. Petrini, and F. Et-migliavacca, « Mechanical Behaviour of Nickel-Titanium Rotary Endodontic Instruments in Simulated Clinical Conditions: A Computational Study, International Endodontic Journal, vol.41, issue.11, pp.939-988, 2008.

X. R. Nóvoa, B. Martin-biedma, P. Varela-patiño, A. Collazo, A. Macías-luaces et al., « The Corrosion of Nickel-titanium Rotary Endodontic Instruments in Sodium Hypochlorite, International Endodontic Journal, vol.40, issue.1, pp.36-44, 2007.

P. Parashos, I. Gordon, and H. H. Et-messer, « Factors Influencing Defects of Rotary Nickel-Titanium Endodontic Instruments after Clinical Use », Journal of Endodontics, vol.30, issue.10, pp.722-727, 2004.

B. Pasternak-júnior, M. D. Sousa-neto, and R. G. Silva, « Canal Transportation and Centring Ability of RaCe Rotary Instruments, International Endodontic Journal, vol.42, issue.6, pp.499-506, 2009.

E. S. Pereira, R. Singh, A. Arias, and O. A. Et-peters, « In Vitro Assessment of Torque and Force Generated by Novel ProTaper Next Instruments during Simulated Canal Preparation, Journal of Endodontics, vol.39, issue.12, pp.1615-1624, 2013.

F. Perez, P. Calas, A. De-falguerolles, and A. Et-maurette, « Migration of a Streptococcus sanguis strain through the root dentinal tubules, Journal of Endodontics, vol.19, issue.6, pp.297-301, 1993.

J. J. Pérez-higueras, A. Arias, J. C. De-la-macorra, and O. A. Et-peters, « Differences in Cyclic Fatigue Resistance between ProTaper Next and ProTaper Universal Instruments at Different Levels », Journal of Endodontics, vol.40, issue.9, pp.1477-81, 2014.

O. A. Peters, « Current Challenges and Concepts in the Preparation of Root Canal Systems: A Review », Journal of Endodontics, vol.30, issue.8, pp.559-67, 2004.

B. Piotrowski, « Analyse numérique et expérimentale du comportement d'un alliage à mémoire de forme avec précipités (Ni47Ti44Nb9) : application à la connectique, 2010.

G. Plotino, N. M. Grande, M. Cordaro, L. Testarelli, and G. Et-gambarini, « Influence of the Shape of Artificial Canals on the Fatigue Resistance of NiTi Rotary Instruments, International Endodontic Journal, vol.43, issue.1, pp.69-75, 2010.

G. Plotino, N. M. Grande, M. C. Melo, M. G. Bahia, L. Testarelli et al., « Cyclic Fatigue of NiTi Rotary Instruments in a Simulated Apical Abrupt Curvature, International Endodontic Journal, vol.43, issue.3, pp.226-256, 2010.

G. Plotino, N. M. Grande, E. Sorci, V. A. Malagnino, and F. Et-somma, « Influence of a Brushing Working Motion on the Fatigue Life of NiTi Rotary Instruments, International Endodontic Journal, vol.40, issue.1, pp.45-51, 2007.

J. P. Pruett, D. J. Clement, and D. L. Et-carnes, « Cyclic fatigue testing of nickeltitanium endodontic instruments, Journal of Endodontics, vol.23, issue.2, pp.80250-80256, 1997.

J. Ramaroson, L. F. Ralaiarimanana, S. R. Alson, F. Fioretti, and G. Et-ralison, « Calcification intracanalaire médiane Apport thérapeutique du CMA », Revue d'odontostomatologie malgache en ligne, vol.3, pp.10-17, 2011.

E. Rapisarda, A. Bonaccorso, T. R. Tripi, I. Fragalk, and G. G. Et-condorelli, « The effect of surface treatments of nickel-titanium files on wear and cutting efficiency ». Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology, vol.89, pp.363-371, 2000.

J. B. Roane, C. L. Sabala, and M. G. Et-duncanson, Concept for Instrumentation of Curved Canals », Journal of Endodontics, vol.11, issue.5, pp.80061-80064, 1985.

M. Roig-cayón, J. Basilio-monné, R. Abós-herrándiz, E. Brau-aguadé, and C. Et-canaldasahli, « A comparison of molar root canal preparations using six instruments and instrumentation techniques, Journal of Endodontics, vol.23, issue.6, pp.383-389, 1997.

M. B. Rowan, J. I. Nicholls, and J. Steiner, « Torsional properties of stainless steel and nickel-titanium endodontic files, Journal of Endodontics, vol.22, issue.7, pp.80214-80221, 1996.

S. E. Saber, M. M. Nagy, and E. Et-schäfer, « Comparative Evaluation of the Shaping Ability of WaveOne, Reciproc and OneShape Single-File Systems in Severely Curved Root Canals of Extracted Teeth, International Endodontic Journal, vol.48, issue.1, pp.109-123, 2015.

S. E. Saber, M. M. Nagy, and E. Et-schäfer, « Comparative Evaluation of the Shaping Ability of ProTaper Next, iRaCe and Hyflex CM Rotary NiTi Files in Severely Curved Root Canals, International Endodontic Journal, vol.48, issue.2, pp.131-137, 2015.

B. Sattapan, J. E. Palamara, and H. H. Et-messer, « Torque during Canal Instrumentation Using Rotary Nickel-Titanium Files », Journal of Endodontics, vol.26, issue.3, pp.156-60, 2000.

E. M. Saunders, « Hand Instrumentation in Root Canal Preparation, Endodontic Topics, vol.10, pp.163-170, 2005.

E. Schäfer, M. Erler, and T. Et-dammaschke, « Comparative Study on the Shaping Ability and Cleaning Efficiency of Rotary Mtwo Instruments. Part 1. Shaping Ability in Simulated Curved Canals, International Endodontic Journal, vol.39, issue.3, pp.196-202, 2006.

E. Schäfer, M. Erler, and T. Et-dammaschke, « Comparative Study on the Shaping Ability and Cleaning Efficiency of Rotary Mtwo Instruments. Part 2. Cleaning Effectiveness and Shaping Ability in Severely Curved Root Canals of Extracted Teeth, International Endodontic Journal, vol.39, issue.3, pp.203-215, 2006.

E. Schäfer and H. Et-florek, « Efficiency of Rotary Nickel-titanium K3 Instruments Compared with Stainless Steel Hand K-Flexofile. Part 1. Shaping Ability in Simulated Curved Canals, International Endodontic Journal, vol.36, issue.3, pp.199-207, 2003.

E. Schäfer, A. Dzepina, and G. Et-danesh, « Bending properties of rotary nickeltitanium instruments ». Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology, vol.96, pp.358-363, 2003.

E. Schäfer, U. Schulz-bongert, and G. Et-tulus, « Comparison of Hand Stainless Steel and Nickel Titanium Rotary Instrumentation: A Clinical Study, Journal of Endodontics, vol.30, issue.6, pp.432-437, 2004.

E. Schäfer and J. Et-tepel, « Relationship Between Design Features of Endodontic Instruments and Their Properties. Part 3. Resistance to Bending and Fracture, Journal of Endodontics, vol.27, issue.4, pp.299-303, 2001.

H. Schilder, « Cleaning and Shaping the Root Canal, Dental Clinics of North America, vol.18, issue.2, pp.269-96, 1974.

C. Schrader, M. Ackermann, and F. Et-barbakow, « Step-by-step description of a rotary root canal preparation technique, International Endodontic Journal, vol.32, issue.4, pp.312-332, 1999.

B. H. Sen, B. Piskin, and T. Et-demirci, « Observation of Bacteria and Fungi in Infected Root Canals and Dentinal Tubules by SEM », Dental Traumatology, vol.11, issue.1, pp.6-9, 1995.

C. K. Sen, S. Khanna, M. Venojarvi, P. Trikha, E. C. Ellison et al., « Copper-Induced Vascular Endothelial Growth Factor Expression and Wound Healing, American Journal of Physiology-Heart and Circulatory Physiology, vol.282, issue.5, 2002.
DOI : 10.1152/ajpheart.01015.2001

B. G. Seto, J. I. Nicholls, and G. W. Et-harrington, « Torsional properties of twisted and machined endodontic files, Journal of Endodontics, vol.16, issue.8, pp.81905-81914, 1990.

S. Shabalovskaya, J. Anderegg, and J. Et-van-humbeeck, « Critical Overview of Nitinol Surfaces and Their Modifications for Medical Applications, Acta Biomaterialia, vol.4, issue.3, pp.447-67, 2008.

J. A. Short, L. A. Morgan, and J. C. Baumgartner, « A comparison of canal centering ability of four instrumentation techniques, Journal of Endodontics, vol.23, issue.8, pp.503-510, 1997.

S. Simon, P. Machtou, W. H. Pertot, and S. Et-friedman, Endodontie. RueilMalmaison, 2012.

P. Sittner, K. Hashimoto, M. Kato, and M. Et-tokuda, « Stress induced martensitic transformations in tension/torsion of CuAlNi single crystal tube, Scripta materialia, vol.48, issue.8, pp.1153-1162, 2003.

Y. L. Song, Z. Bian, B. Fan, M. W. Fan, J. L. Gutmann et al., « A Comparison of Instrument-Centering Ability within the Root Canal for Three Contemporary Instrumentation Techniques », International Endodontic Journal, vol.37, issue.4, pp.265-71, 2004.

G. Spagnuolo, G. Ametrano, V. D'antò, C. Rengo, M. Simeone et al., Effect of Autoclaving on the Surfaces of TiN-Coated and Conventional Nickel-titanium Rotary Instruments, vol.45, pp.1148-55, 2012.

A. P. Spanaki-voreadi, N. P. Kerezoudis, and S. Et-zinelis, « Failure Mechanism of ProTaper Ni-Ti Rotary Instruments during Clinical Use: Fractographic Analysis, International Endodontic Journal, vol.39, issue.3, pp.171-179, 2006.

K. M. Speck and A. C. Et-fraker, « Anodic polarization of Ti-Ni and Ti-6Al-4V in simulated physiological solutions, ResearchGate, vol.59, issue.10, pp.1590-1595, 1980.

L. Testarelli, N. M. Grande, G. Plotino, M. Lendini, G. Pongione et al., Cyclic Fatigue of Different Nickel-Titanium Rotary Instruments: A Comparative Study, vol.3, pp.55-63, 2009.

S. A. Thompson, « An Overview of Nickel-Titanium Alloys Used in Dentistry, International Endodontic Journal, vol.33, issue.4, pp.297-310, 2000.

T. R. Tripi, A. Bonaccorso, and G. G. Et-condorelli, « Cyclic fatigue of different nickeltitanium endodontic rotary instruments ». Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology, vol.102, pp.106-120, 2006.

C. J. Ullmann and O. A. Et-peters, « Effect of Cyclic Fatigue on Static Fracture Loads in ProTaper Nickel-Titanium Rotary Instruments, Journal of Endodontics, vol.31, issue.3, pp.183-189, 2005.

P. Varela-patiño, A. Ibañez-párraga, B. Rivas-mundiña, G. Cantatore, X. L. Otero et al., « Alternating versus Continuous Rotation: A Comparative Study of the Effect on Instrument Life, Journal of Endodontics, vol.36, issue.1, pp.157-166, 2010.

J. Versümer, M. Hülsmann, and F. Et-schäfers, « A Comparative Study of Root Canal Preparation Using ProFile .04 and Lightspeed Rotary Ni-Ti Instruments, International Endodontic Journal, vol.35, issue.1, pp.37-46, 2002.

E. P. Vieira, E. C. França, R. C. Martins, V. T. Buono, and M. G. Et-bahia, « Influence of Multiple Clinical Use on Fatigue Resistance of ProTaper Rotary Nickel-Titanium Instruments, International Endodontic Journal, vol.41, issue.2, pp.163-72, 2008.

E. P. Vieira, R. K. Nakagawa, V. T. Buono, and M. G. Et-bahia, « Torsional Behaviour of Rotary NiTi ProTaper Universal Instruments after Multiple Clinical Use, International Endodontic Journal, vol.42, issue.10, pp.947-53, 2009.

M. Vincent, F. Thiebaud, S. B. Khalifa, M. Engels-deutsch, B. Zineb et al., Finite Element Analysis of a Copper Single Crystal Shape Memory Alloy-Based Endodontic Instruments, J. Mater. Eng. Perform, vol.24, pp.4128-4139, 2015.
URL : https://hal.archives-ouvertes.fr/hal-01417914

M. Vincent, « Développement d'un instrument endodontique en alliage à mémoire de forme monocristallin cuivreux, 2017.

T. S. Vinothkumar, R. Miglani, and L. Et-lakshminarayananan, « Influence of Deep Dry Cryogenic Treatment on Cutting Efficiency and Wear Resistance of Nickel-Titanium Rotary Endodontic Instruments, Journal of Endodontics, vol.33, issue.11, pp.1355-1363, 2007.

H. Walia, W. A. Brantley, and H. Et-gerstein, « An initial investigation of the bending and torsional properties of nitinol root canal files, Journal of Endodontics, vol.14, issue.7, pp.80196-80197, 1988.

M. S. Weschler, D. S. Lieberman, and T. A. Et-read, « On the theory of the formation of martensite », Journal of Metallurgy, pp.1503-1518, 0197.

W. L. Wildey and E. S. Et-senia, « A new root canal instrument and instrumentation technique: A preliminary report ». Oral Surgery, Oral Medicine, Oral Pathology, vol.67, issue.2, pp.198-207, 1989.

C. F. Wolle, M. A. Vasconcellos, R. Hinrichs, A. N. Becker, and F. B. Et-barletta, « The Effect of Argon and Nitrogen Ion Implantation on Nickel-Titanium Rotary Instruments, Journal of Endodontics, vol.35, issue.11, pp.1558-62, 2009.

X. Xu, M. Eng, Y. Zheng, and D. Et-eng, « Comparative Study of Torsional and Bending Properties for Six Models of Nickel-Titanium Root Canal Instruments with Different Cross-Sections », Journal of Endodontics, vol.32, issue.4, pp.372-377, 2006.

G. B. Yang, X. D. Zhou, H. Zhang, and H. K. Et-wu, « Shaping Ability of Progressive versus Constant Taper Instruments in Simulated Root Canals, International Endodontic Journal, vol.39, issue.10, pp.791-800, 2006.

G. B. Yang, X. D. Zhou, Y. L. Zheng, H. Zhang, Y. Shu et al., « Shaping Ability of Progressive versus Constant Taper Instruments in Curved Root Canals of Extracted Teeth, International Endodontic Journal, vol.40, issue.9, pp.707-721, 2007.

G. Yared, G. K. Kulkarni, and F. Et-ghossayn, « An in Vitro Study of the Torsional Properties of New and Used K3 Instruments, International Endodontic Journal, vol.36, issue.11, pp.764-773, 2003.

G. M. Yared, F. E. Bou-dagher, and P. Et-machtou, « Failure of ProFile Instruments Used with High and Low Torque Motors, International Endodontic Journal, vol.34, issue.6, pp.471-476, 2001.

G. M. Yared, F. E. Bou-dagher, P. Machtou, and G. K. Et-kulkarni, « Influence of Rotational Speed, Torque and Operator Proficiency on Failure of Greater Taper Files, International Endodontic Journal, vol.35, issue.1, pp.7-12, 2002.

G. M. Yared, F. E. Bou-dagher, and . Et-machtou, Cyclic Fatigue of Profile Rotary Instruments after Simulated Clinical Use, International Endodontic Journal, vol.32, issue.2, pp.115-124, 1999.

T. Yoneyama, H. Doi, H. Hamanaka, Y. Okamoto, M. Mogi et al., Super-Elasticity and Thermal Behavior of Ni-Ti Alloy Orthodontic Arch Wires, Dental Materials Journal, vol.11, issue.1, pp.1-10, 1992.

T. Yoneyama, H. Doi, H. Hamanaka, M. Yamamoto, and T. Et-kuroda, « Bending Properties and Transformation Temperatures of Heat Treated Ni-Ti Alloy Wire for Orthodontic Appliances, Journal of Biomedical Materials Research, vol.27, issue.3, pp.399-402, 1993.

S. Zinelis, M. Darabara, T. Takase, K. Ogane, and G. D. Et-papadimitriou, « The Effect of Thermal Treatment on the Resistance of Nickel-Titanium Rotary Files in Cyclic Fatigue ». Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontics, vol.103, issue.6, pp.843-850, 2007.

O. Zmener and L. Et-balbachan, « Effectiveness of Nickel-Titanium Files for Preparing Curved Root Canals, Endodontics & Dental Traumatology, vol.11, issue.3, pp.121-124, 1995.

. , Historique et état de l'art de la mise en forme canalaire

.. .. La-mise-en-forme-canalaire-manuelle,

.. .. La-mise-en-forme-canalaire-mécanisée,

L. and .. .. ,

. .. Les-instruments-soniques,

. .. Les-instruments-rotatifs,

.. .. Les-alliages-À-mémoire-de-forme,

. .. Endodontie, 18 2.3.2.1 L'efficacité de mise en forme canalaire, la sécurité et la rapidité d'utilisation, Les différents intérêts de la rotation continue en

. , L'évolution des instruments endodontiques

. .. Le-design-instrumental, 4.2 Le mouvement de travail instrumental intra-canalaire

.. .. Les-traitements-de-surface,

. .. Les-traitements-thermiques,

.. .. Le-procédé-de-fabrication,

. .. Matériel-de-test,

L. Contre,

.. .. Les-blocs-en-résine,

L. Différents-systèmes-À-tester and .. .. ,

L. , M. Niti, and .. .. En-cualbe,

C. Endo® and C. .. Hyflex,

.. .. Le-dispositif-de-mise-en-place,

. Le-logiciel-pilote-de,

. .. Méthode-de-test,

. , Les tests sans irrigation : cyclage simple

. , Les tests avec irrigation : l'essai libre

.. .. Le-protocole-de-test,

. .. Résultats,

L. , M. Nickel-titane, and .. .. ,

. , La broche MICRO-MEGA® de 25/100? de mm, de conicité 2% dans un canal courbé à 20°

, La broche MICRO-MEGA® de 30/100? de mm, de conicité 2%, p.54

M. .. Le-système,

. .. L'endoflare®,

S. Le and S. .. Le,

. .. Conclusion,

D. Le-système and . Maillefer®,

L. Sx and . .. Le-s2,

F. .. Les,

. .. Conclusion,

C. .. Le-système,

L. .. Coronal®,

L. Median® and .. .. ,

. .. Conclusion,

C. Le-système, . Endo®, and C. .. Hyflex,

. .. Conclusion,

, Les broches MICRO-MEGA® en CuAlBe de conicité 2%

.. .. De-millimètre,

. .. Synthèse,

. .. Discussion,

.. .. Les,

.. .. Le-banc-d'essai,

. .. Conclusion, , vol.87

. .. Bibliographie,

, et ayant pour titre : «Etude du comportement mécanique de limes endodontiques en alliage à mémoire de forme durant la préparation canalaire»

, Autorise à soutenir et imprimer la thèse NANCY, Je