Fast fault detection and reconfiguration is necessary in power electronic converters in lots of applications to prevent further damage and to make possible the continuity of service. In this paper a very fast fault detection scheme is presented that minimizes the use of voltage sensors. A fault tolerant topology is studied. Control and fault detection system are implemented on a single FPGA and hardware in the loop experiments are performed to evaluate the detection scheme, the digital controller and the structure.
Fichier non déposé

Dates et versions

hal-03565742 , version 1 (11-02-2022)

Identifiants

Citer

Mahmoud Shahbazi, Mohammadreza Zolghadri, Philippe Poure, Shahrokh Saadate. Fast detection of open-switch faults with reduced sensor count for a fault-tolerant three-phase converter. Technologies Conference (PEDSTC), Feb 2011, Tehran, Iran. pp.546-550, ⟨10.1109/PEDSTC.2011.5742479⟩. ⟨hal-03565742⟩