. ". Staines, Quantifying"head"motion"associated"with"motor"tasks"used"in"fMRI, Neuroimage, vol.14, issue.2, pp.284-97, 2001.

. Washington, C'est"aussi"durant"cette"période"qu'elle"se"maria"à"un"médecin,"et"eut" deux"enfantsAprès"le"décès"de"DANDY,"elle"continua"ses"recherches"à"la"CARNEGIE"Institution" de" 1946 C'est" là" qu'elle" publia" en" 1948" dans" les" Contributions(to(Embryology"son"remarquable"et"inégalé"article"sur"la"morphogenèse"des"artères" cérébrales The"development"of"the"cranial"arteries"in"the"human"embryoElle"travailla"aussi" sur" l'embryologie" des" veines" vertébrales," recherche" qui" se" continua" après" son" départ The" development"of"the"cranial"venous"system"in"man, 1952.

J. D. Blumenthal, A. Zijdenbos, E. Molloy, and J. N. Giedd, Motion Artifact in Magnetic Resonance Imaging: Implications for Automated Analysis, NeuroImage, vol.16, issue.1, pp.89-92, 2002.
DOI : 10.1006/nimg.2002.1076

C. W. Chan, B. W. Choi, M. Jinzaki, K. Kitagawa, I. C. Tsai et al., ASCI 2010 standardized practice protocol for cardiac magnetic resonance imaging: a report of the Asian society of cardiovascular imaging cardiac computed tomography and cardiac magnetic resonance imaging guideline working group, The International Journal of Cardiovascular Imaging, vol.11, issue.17, pp.187-202, 2010.
DOI : 10.1007/s10554-010-9708-y

D. De-ridder, A. Moller, J. Verlooy, M. Cornelissen, and L. De-ridder, Is the Root Entry/Exit Zone Important in Microvascular Compression Syndromes?, Neurosurgery, vol.94, issue.3, pp.427-433, 2002.
DOI : 10.1001/archneurpsyc.1937.02260150085005

D. R. Enzmann and N. J. Pelc, Normal flow patterns of intracranial and spinal cerebrospinal fluid defined with phase-contrast cine MR imaging., Radiology, vol.178, issue.2, pp.467-474, 1991.
DOI : 10.1148/radiology.178.2.1987610

D. R. Enzmann and N. J. Pelc, Brain motion: measurement with phase-contrast MR imaging., Radiology, vol.185, issue.3, pp.653-660, 1992.
DOI : 10.1148/radiology.185.3.1438741

D. Greitz, A. Franck, and B. Nordell, On the Pulsatile Nature of Intracranial and Spinal CSF-Circulation Demonstrated by MR Imaging, Acta Radiologica, vol.100, issue.4, pp.321-328, 1993.
DOI : 10.1093/brain/83.3.454

D. Greitz, R. Wirestam, A. Franck, B. Nordell, C. Thomsen et al., Pulsatile brain movement and associated hydrodynamics studied by magnetic resonance phase imaging, Neuroradiology, vol.1, issue.Suppl 45, pp.370-380, 1992.
DOI : 10.1001/archsurg.1929.01140130137006

T. B. Jones, P. A. Bandettini, and R. M. Birn, Integration of motion correction and physiological noise regression in fMRI, NeuroImage, vol.42, issue.2, pp.582-590, 2008.
DOI : 10.1016/j.neuroimage.2008.05.019

S. A. Kruse, G. H. Rose, K. J. Glaser, A. Manduca, J. P. Felmlee et al., Magnetic resonance elastography of the brain, NeuroImage, vol.39, issue.1, pp.231-237, 2008.
DOI : 10.1016/j.neuroimage.2007.08.030

S. E. Maier, C. J. Hardy, and F. A. Jolesz, Brain and cerebrospinal fluid motion: real-time quantification with M-mode MR imaging., Radiology, vol.193, issue.2, pp.477-483, 1994.
DOI : 10.1148/radiology.193.2.7972766

O. Ozdogmus, O. Sezen, U. Kubilay, E. Saka, U. Duman et al., Connections between the facial, vestibular and cochlear nerve bundles within the internal auditory canal, Journal of Anatomy, vol.205, issue.1, pp.65-75, 2004.
DOI : 10.1111/j.0021-8782.2004.00313.x

B. P. Poncelet, V. J. Wedeen, R. M. Weisskoff, and M. S. Cohen, Brain parenchyma motion: measurement with cine echo-planar MR imaging., Radiology, vol.185, issue.3, pp.645-651, 1992.
DOI : 10.1148/radiology.185.3.1438740

C. S. Rebert, R. E. Hurd, M. J. Matteucci, R. De-lapaz, and D. R. Enzmann, A procedure for using proton magnetic resonance imaging to determine stereotaxic coordinates of the monkey's brain, Journal of Neuroscience Methods, vol.39, issue.2, pp.109-113, 1991.
DOI : 10.1016/0165-0270(91)90076-C

E. Seto, G. Sela, W. E. Mcilroy, S. E. Black, W. R. Staines et al., Quantifying Head Motion Associated with Motor Tasks Used in fMRI, NeuroImage, vol.14, issue.2, pp.284-297, 2001.
DOI : 10.1006/nimg.2001.0829

M. Soellinger, A. K. Rutz, S. Kozerke, and P. Boesiger, 3D cine displacement-encoded MRI of pulsatile brain motion, Magnetic Resonance in Medicine, vol.27, issue.Pt 1, pp.153-162, 2009.
DOI : 10.1148/radiology.185.3.1438740

M. Soellinger, S. Ryf, P. Boesiger, and S. Kozerke, Assessment of human brain motion using CSPAMM, Journal of Magnetic Resonance Imaging, vol.3749, issue.4, pp.709-714, 2007.
DOI : 10.1148/radiology.172.2.2748813

A. M. Taylor and J. Bogaert, Cardiovascular MR Imaging Planes and Segmentation, pp.85-98, 2005.

S. Yang, T. J. Ross, Y. Zhang, E. A. Stein, and Y. Yang, Head motion suppression using real-time feedback of motion information and its effects on task performance in fMRI, NeuroImage, vol.27, issue.1, pp.153-162, 2005.
DOI : 10.1016/j.neuroimage.2005.02.050

M. Zaitsev, C. Dold, G. Sakas, J. Hennig, and O. Speck, Magnetic resonance imaging of freely moving objects: prospective real-time motion correction using an external optical motion tracking system, NeuroImage, vol.31, issue.3, pp.1038-1050, 2006.
DOI : 10.1016/j.neuroimage.2006.01.039

X. Zhong, C. H. Meyer, D. J. Schlesinger, J. P. Sheehan, F. H. Epstein et al., Tracking brain motion during the cardiac cycle using spiral cine-DENSE MRI, Medical Physics, vol.18, issue.8, pp.3413-3419, 2009.
DOI : 10.1016/S0730-725X(00)00195-8

M. Labrousse, In vivo characterization of the vestibulo-cochlear nerve motion by MRI, NeuroImage, vol.59, issue.2, 2011.
DOI : 10.1016/j.neuroimage.2011.08.058