Restauration et Analyse de l'ECG acquis pendant les examens d'imagerie à résonance magnétique, 2005. ,
Suppression of MR gradient artefacts on electrophysiological signals based on an adaptive real-time filter with LMS coefficient updates, Magnetic Resonance Materials in Physics Biology, and Medicine, vol.18, issue.1, pp.41-50, 2005. ,
URL : https://hal.archives-ouvertes.fr/inserm-00616723
Predictive Cardiac Motion Modeling and Correction With Partial Least Squares Regression, IEEE Transactions on Medical Imaging, vol.23, issue.10, pp.23-1315, 2004. ,
DOI : 10.1109/TMI.2004.834622
Respiratory reordered UNFOLD perfusion imaging, Journal of Magnetic Resonance Imaging, vol.20, issue.5, pp.817-825, 2004. ,
High-speed spiral-scan echo planar NMR imaging -Part 1, Z. H. IEEE Transactions on Medical Imaging, issue.1, pp.5-7, 1986. ,
DOI : 10.1109/tmi.1986.4307732
Automatic compensation of motion artifacts in MRI, Magnetic Resonance in Medicine, vol.18, issue.1, pp.163-170, 1999. ,
DOI : 10.1148/radiology.205.2.9356642
Augmented generalized SENSE reconstruction to correct for rigid body motion, Magnetic Resonance in Medicine, vol.20, issue.1, pp.90-102, 2007. ,
DOI : 10.1002/mrm.21106
Matrix description of general motion correction applied to multishot images, Magnetic Resonance in Medicine, vol.21, issue.5, pp.1273-1280, 2005. ,
DOI : 10.1002/mrm.20656
Handbook of MRI Pulse Sequences, 2004. ,
MRI-based measurements of respiratory motion variability and assessment of imaging strategies for radiotherapy planning, Physics in Medicine and Biology, vol.51, issue.17, pp.51-4147, 2006. ,
DOI : 10.1088/0031-9155/51/17/003
From Pixels to Regions: Partial Differential Equations in Image Analysis, 2005. ,
High Accuracy Optical Flow Estimation Based on a Theory for Warping, Pages 25?36 of:8th European Conference on Computer Vision, 2004. ,
DOI : 10.1007/978-3-540-24673-2_3
Detection and elimination of motion artifacts by regeneration ofk-space, Magnetic Resonance in Medicine, vol.13, issue.4, pp.677-686, 2002. ,
DOI : 10.1002/jmri.1072
An algotihm for NMR imaging reconstruction based on multiple RF receiver coils, Journal of Magnetic Resonance, vol.74, pp.376-380, 1987. ,
Mathematical Models for local nontexture inpaintings, SIAM Journal on Applied Mathematics, vol.62, pp.1019-1043, 2002. ,
Deformable templates using large deformation kinematics, IEEE Transactions on Image Processing, vol.5, issue.10, pp.1435-1447, 1996. ,
DOI : 10.1109/83.536892
Automated rectilinear self-gated cardiac cine imaging, Magnetic Resonance in Medicine, vol.52, issue.4, pp.782-788, 2004. ,
Tumor detection by nuclear magnetic resonance Prospective navigator correction of image position for coronary MR angiography, Science, [Danias et al. Radiology, issue.3, pp.203-733, 1971. ,
SIMPLS: An alternative approach to partial least squares regression, Chemometrics and Intelligent Laboratory Systems, vol.18, issue.3, pp.251-263, 1993. ,
DOI : 10.1016/0169-7439(93)85002-X
Pulse oximetry-gated acquisition of cardiac MR images in patients with congenital cardiac abnormalities., American Journal of Roentgenology, vol.160, issue.4, pp.831-833, 1993. ,
DOI : 10.2214/ajr.160.4.8456674
Motion-compensated MR valve imaging with COMB tag tracking and super-resolution enhancement, Medical Image Computing and Computer Assisted Intervention International Conference, pp.364-371, 2006. ,
Amplitude demodulation of the electrocardiogram signal (ECG) for respiration monitoring and compensation during MR examinations, Magnetic Resonance in Medicine, vol.33, issue.6, pp.129-136, 1997. ,
DOI : 10.1148/radiology.160.3.3737921
Restoration of electrophysiological signals distorted by inductive effects of magnetic field gradients during MR sequences, Magnetic Resonance in Medicine, vol.171, issue.4, pp.715-721, 1999. ,
DOI : 10.1148/radiology.171.3.2717770
Partial least-squares regression: a tutorial, Analytica Chimica Acta, vol.185, pp.1-17, 1986. ,
DOI : 10.1016/0003-2670(86)80028-9
Projection Reconstruction Techniques for Reduction of Motion Effects in MRI, Magnetic Resonance in Medicine, vol.19, issue.2, pp.275-289, 1992. ,
DOI : 10.1148/radiology.181.1.1909445
Generalized autocalibrating partially parallel acquisitions (GRAPPA), Magnetic Resonance in Medicine, vol.41, issue.6, pp.47-1202, 2002. ,
DOI : 10.1002/(SICI)1522-2594(199906)41:6<1236::AID-MRM21>3.0.CO;2-T
URL : http://www.ece.neu.edu/groups/biomed/bspi_mri_conc_2102/SVGRAPPA_p1202.pdf
Reducing motion artifacts in twodimensional Fourier transform imaging, Magnetic Resonance in Medicine, vol.4, pp.359-76, 1986. ,
Magnetic Resonance Imaging: Physical Principles and Sequence Design, 1999. ,
3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography, European Radiology, vol.201, issue.4, pp.15-1598, 2005. ,
DOI : 10.1148/radiology.201.3.8939242
Tissue deformation and shape models in image-guided interventions: a discussion paper, Medical Image Analysis, vol.9, issue.2, pp.163-175, 2005. ,
DOI : 10.1016/j.media.2004.11.007
RARE imaging: A fast imaging method for clinical MR, Magnetic Resonance in Medicine, vol.10, issue.6, pp.823-833, 1986. ,
DOI : 10.1063/1.1716296
Variational methods for multimodal image matching, 2002. ,
URL : https://hal.archives-ouvertes.fr/tel-00457459
Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP), Magnetic Resonance in Medicine, vol.3, issue.2, pp.301-308, 2000. ,
DOI : 10.1002/mrm.1910350419
Self-gated cardiac cine MRI, Magnetic Resonance in Medicine, vol.7, issue.1, pp.93-102, 2004. ,
DOI : 10.1002/jmri.1880070505
URL : http://onlinelibrary.wiley.com/doi/10.1002/mrm.10664/pdf
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance, Nature, vol.178, issue.5394, pp.190-191, 1973. ,
DOI : 10.1038/242190a0
An Iterative Image Registration Technique with an Application to Stereo Vision, Pages 121?130 of:Proceedings of Imaging Understanding Workshop, 1981. ,
Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI, Magnetic Resonance in Medicine, vol.93, issue.5, pp.813-828, 1999. ,
DOI : 10.1148/radiology.195.2.7724769
Novel prospective respiratory motion correction approach for free-breathing coronary MR angiography using a patient-adapted affine motion model, Magnetic Resonance in Medicine, vol.214, issue.1, pp.122-131, 2003. ,
DOI : 10.1148/radiology.214.1.r00ja41283
Multi-planar image formation using NMR spin echoes, Journal of Physics C: Solid State Physics, vol.10, issue.3, 1977. ,
DOI : 10.1088/0022-3719/10/3/004
A study of the motion and deformation of the heart due to respiration, IEEE Transactions on Medical Imaging, vol.21, issue.9, pp.1142-1150, 2002. ,
DOI : 10.1109/TMI.2002.804427
Fast Spiral Coronary Artery Imaging, Magnetic Resonance in Medicine, vol.25, issue.2, pp.202-213, 1992. ,
DOI : 10.2214/ajr.149.2.245
Intensity correction of phased-array surface coil images, Magnetic Resonance in Medicine, vol.5, issue.4, pp.585-590, 1996. ,
DOI : 10.1002/jmri.1880050204
Free-breathing Cardiac MR Imaging: Study of Implications of Respiratory Motion???Initial Results, Radiology, vol.220, issue.3, pp.810-815, 2001. ,
DOI : 10.1148/radiol.2203010132
Prospective correction of affine motion for arbitrary MR sequences on a clinical scanner, Magnetic Resonance in Medicine, vol.51, issue.5, pp.1130-1138, 2005. ,
DOI : 10.1007/978-1-4757-1904-8
Homodyne detection in magnetic resonance imaging, IEEE Transactions on Medical Imaging, vol.10, issue.2, pp.154-163, 1991. ,
DOI : 10.1109/42.79473
Real-time electrocardiogram artifact correction using a finite impulse response maneuvres by dynamic MRI: comparison between healthy adults and patients with pulmonary hypertension, European Radiology, vol.16, issue.1, pp.173-179, 2006. ,
Mutual-informationbased registration of medical images: a survey, IEEE Transactions on Medical Imaging, issue.8, pp.22-986, 2003. ,
Evaluation of linear diaphragm???chest expansion models for magnetic resonance imaging motion artifact correction, Computers in Biology and Medicine, vol.29, issue.2, 1999. ,
DOI : 10.1016/S0010-4825(98)00050-X
Nonlinear total variation based noise removal algorithms, Physica D: Nonlinear Phenomena, vol.60, issue.1-4, pp.259-268, 1992. ,
DOI : 10.1016/0167-2789(92)90242-F
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays, Magnetic Resonance in Medicine, vol.18, issue.4, pp.591-603, 1997. ,
DOI : 10.1002/mrm.1910350419
k-t BLAST andk-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations, Magnetic Resonance in Medicine, vol.46, issue.5, pp.1031-1042, 2003. ,
DOI : 10.1002/mrm.1237
Whole-heart cine MRI using real-time respiratory self-gating, Magnetic Resonance in Medicine, vol.57, issue.3, pp.606-613, 2007. ,
Iterative Methods for Total Variation Denoising, SIAM Journal on Scientific Computing, vol.17, issue.1, pp.227-238, 1996. ,
DOI : 10.1137/0917016
Fast, robust total variation-based reconstruction of noisy, blurred images, IEEE Transactions on Image Processing, vol.7, issue.6, pp.813-824, 1998. ,
DOI : 10.1109/83.679423
Faulty trigger and motion artifact canceling in cardiac MRI using SPACE-RIP, 2007. ,
Respiratory Motion of the Heart: Kinematics and the Implications for the Spatial Resolution in Coronary Imaging, Magnetic Resonance in Medicine, vol.173, issue.5, pp.713-719, 1995. ,
DOI : 10.1148/radiology.173.1.2781017
Variational optic flow computation with a spatio-temporal smoothness constraint, Journal of Mathematical Imaging and Vision, vol.14, issue.3, pp.245-255, 2001. ,
DOI : 10.1023/A:1011286029287
Spherical navigator echoes for full 3D rigid body motion measurement in MRI, Magnetic Resonance in Medicine, vol.47, issue.1, pp.32-41, 2002. ,
Parallel imaging performance as a function of field strength?an experimental investigation using electrodynamic scaling, Magnetic Resonance in Medicine, vol.52, issue.5, pp.953-964, 2004. ,
Phase-constrained parallel MR image reconstruction, Journal of Magnetic Resonance, vol.176, issue.2, pp.187-198, 2005. ,
DOI : 10.1016/j.jmr.2005.06.004
Ghost artifact removal using a parallel imaging approach, Magnetic Resonance in Medicine, vol.18, issue.4, pp.1002-1009, 2005. ,
DOI : 10.1002/mrm.20640
MR image artifacts from periodic motion, Medical Physics, vol.12, issue.2, pp.143-151, 1985. ,
DOI : 10.1118/1.595782
Optimal Sensor Placement for Predictive Cardiac Motion Modeling, Proceedings 9th International Conference, pp.512-519, 2006. ,
DOI : 10.1007/11866763_63
Parallel magnetic resonance imaging with adaptive radius in k-space (PARS): constrained image reconstruction using k-space locality in radiofrequency coil encoded data, 2005. ,