B. 1. Leksell and L. , The stereotaxic method and radiosurgery of the brain, Acta Chir Scand, vol.102, issue.4, pp.316-325, 1951.

S. H. Benedict, K. M. Yenice, D. Followill, J. M. Galvin, W. Hinson et al., Stereotactic body radiation therapy: The report of AAPM Task Group 101, Medical Physics, vol.71, issue.3, pp.4078-101
DOI : 10.1016/j.ijrobp.2007.06.086

K. R. Winston and W. Lutz, Linear Accelerator as a Neurosurgical Tool for Stereotactic Radiosurgery, Neurosurgery, vol.22, issue.3, pp.454-64, 1988.
DOI : 10.1227/00006123-198803000-00002

W. Lutz, K. R. Winston, and N. Maleki, A system for stereotactic radiosurgery with a linear accelerator, International Journal of Radiation Oncology*Biology*Physics, vol.14, issue.2, pp.373-81, 1988.
DOI : 10.1016/0360-3016(88)90446-4

E. Coste-maniere, D. Olender, W. Kilby, and R. A. Schulz, Robotic whole body stereotactic radiosurgery: clinical advantages of the Cyberknife?? integrated system, The International Journal of Medical Robotics and Computer Assisted Surgery, vol.75, issue.2, pp.28-39, 2005.
DOI : 10.1177/153303460300200104

C. Ozhasoglu, C. B. Saw, H. Chen, S. Burton, K. Komanduri et al., Synchrony ??? Cyberknife Respiratory Compensation Technology, Medical Dosimetry, vol.33, issue.2, pp.117-140, 2008.
DOI : 10.1016/j.meddos.2008.02.004

W. Kilby, J. R. Dooley, G. Kuduvalli, S. Sayeh, C. R. Maurer et al., The CyberKnife?? Robotic Radiosurgery System in 2010, Technology in Cancer Research & Treatment, vol.49, issue.5, pp.433-52
DOI : 10.1177/153303460700600409

J. R. Adler, R. Jr, G. Bower, M. Gupta, A. Lim et al., NONISOCENTRIC RADIOSURGICAL RHIZOTOMY FOR TRIGEMINAL NEURALGIA, Neurosurgery, vol.62, issue.suppl_2, pp.84-90, 2009.
DOI : 10.1227/01.neu.0000317313.46826.dc

F. Colombo, L. Casentini, C. Cavedon, P. Scalchi, S. Cora et al., CYBERKNIFE RADIOSURGERY FOR BENIGN MENINGIOMAS, Neurosurgery, vol.143, issue.suppl_2, pp.7-13, 2009.
DOI : 10.1007/s007010100005

F. Colombo, C. Cavedon, L. Casentini, P. Francescon, F. Causin et al., Early results of CyberKnife radiosurgery for arteriovenous malformations, Journal of Neurosurgery, vol.21, issue.4, pp.807-826, 2009.
DOI : 10.1118/1.597344

S. G. Soltys, J. R. Adler, J. D. Lipani, P. S. Jackson, C. Y. Choi et al., Stereotactic Radiosurgery of the Postoperative Resection Cavity for Brain Metastases, International Journal of Radiation Oncology*Biology*Physics, vol.70, issue.1, pp.187-93, 2008.
DOI : 10.1016/j.ijrobp.2007.06.068

B. Wowra, A. Muacevic, and J. C. Tonn, Quality of radiosurgery for single brain metastases with respect to treatment technology: a matched-pair analysis, Journal of Neuro-Oncology, vol.5, issue.1, pp.69-77, 2009.
DOI : 10.1177/153303460700600409

G. J. Gagnon, N. M. Nasr, J. J. Liao, I. Molzahn, D. Marsh et al., TREATMENT OF SPINAL TUMORS USING CYBERKNIFE FRACTIONATED STEREOTACTIC RADIOSURGERY, Neurosurgery, vol.97, issue.2, pp.297-306, 2009.
DOI : 10.1016/j.ijrobp.2004.12.092

P. C. Gerszten, S. A. Burton, and C. Ozhasoglu, CyberKnife Radiosurgery for Spinal Neoplasms, Prog Neurol Surg, vol.20, pp.340-58, 2007.
DOI : 10.1159/000100177

P. C. Gerszten, S. A. Burton, C. Ozhasoglu, and W. C. Welch, Radiosurgery for Spinal Metastases, Spine, vol.32, issue.2, pp.193-202, 1976.
DOI : 10.1097/01.brs.0000251863.76595.a2

I. C. Gibbs, Spinal and Paraspinal Lesions: The Role of Stereotactic Body Radiotherapy
DOI : 10.1159/000106050

A. Sahgal, C. Ames, D. Chou, L. Ma, K. Huang et al., Stereotactic Body Radiotherapy Is Effective Salvage Therapy for Patients With Prior Radiation of Spinal Metastases, International Journal of Radiation Oncology*Biology*Physics, vol.74, issue.3, pp.74-723, 2009.
DOI : 10.1016/j.ijrobp.2008.09.020

J. Sinclair, S. D. Chang, I. C. Gibbs, J. R. Adler, and J. , Multisession CyberKnife Radiosurgery for Intramedullary Spinal Cord Arteriovenous Malformations, Neurosurgery, vol.20, issue.3, pp.1081-1090, 2006.
DOI : 10.1016/0360-3016(91)90249-4

W. T. Brown, X. Wu, F. Fayad, J. F. Fowler, S. Garcia et al., Application of Robotic Stereotactic Radiotherapy to Peripheral Stage I Non-small Cell Lung Cancer with Curative Intent, Clinical Oncology, vol.21, issue.8, pp.21-623, 2009.
DOI : 10.1016/j.clon.2009.06.006

B. T. Collins, S. Vahdat, K. Erickson, S. P. Collins, S. Suy et al., Radical cyberknife radiosurgery with tumor tracking: an effective treatment for inoperable small peripheral stage I non-small cell lung cancer, Journal of Hematology & Oncology, vol.2, issue.1, p.1, 2009.
DOI : 10.1186/1756-8722-2-1

D. Coon, A. S. Gokhale, S. A. Burton, D. E. Heron, C. Ozhasoglu et al., Fractionated Stereotactic Body Radiation Therapy in the Treatment of Primary, Recurrent, and Metastatic Lung Tumors: The Role of Positron Emission Tomography/Computed Tomography???Based Treatment Planning, Clinical Lung Cancer, vol.9, issue.4, pp.217-238, 2008.
DOI : 10.3816/CLC.2008.n.032

A. Pennathur, J. D. Luketich, D. E. Heron, M. J. Schuchert, S. Burton et al., Stereotactic Radiosurgery for the Treatment of Lung Neoplasm: Experience in 100 Consecutive Patients, The Annals of Thoracic Surgery, vol.88, issue.5, pp.1594-600, 2009.
DOI : 10.1016/j.athoracsur.2009.05.020

. Levendag, Stereotactic radiotherapy with real-time tumor tracking for non-small cell lung cancer: clinical outcome, Radiother Oncol, issue.3, pp.91-296, 2009.

J. L. Friedland, D. E. Freeman, M. E. Masterson-mcgary, and D. M. Spellberg, Stereotactic Body Radiotherapy: An Emerging Treatment Approach for Localized Prostate Cancer, Technology in Cancer Research & Treatment, vol.8, issue.5
DOI : 10.1016/j.ijrobp.2005.07.540

D. B. Fuller, J. Naitoh, C. Lee, S. Hardy, and H. Jin, Virtual HDRSM CyberKnife Treatment for Localized Prostatic Carcinoma: Dosimetry Comparison With HDR Brachytherapy and Preliminary Clinical Observations, International Journal of Radiation Oncology*Biology*Physics, vol.70, issue.5, pp.70-1588, 2008.
DOI : 10.1016/j.ijrobp.2007.11.067

A. J. Katz, M. Santoro, R. Ashley, F. Diblasio, and M. Witten, Stereotactic Body Radiotherapy as Boost for Organ-confined Prostate Cancer, Technology in Cancer Research & Treatment, vol.6, issue.6, pp.575-82
DOI : 10.1016/j.ijrobp.2008.04.051

A. J. Katz, M. Santoro, R. Ashley, F. Diblasio, and M. Witten, Stereotactic body radiotherapy for organ-confined prostate cancer, BMC Urology, vol.60, issue.1, p.1
DOI : 10.1016/j.ijrobp.2004.07.364

C. R. King, J. D. Brooks, H. Gill, T. Pawlicki, C. Cotrutz et al., Stereotactic Body Radiotherapy for Localized Prostate Cancer: Interim Results of a Prospective Phase II Clinical Trial, International Journal of Radiation Oncology*Biology*Physics, vol.73, issue.4, pp.73-1043, 2009.
DOI : 10.1016/j.ijrobp.2008.05.059

B. O. Choi, I. B. Choi, H. S. Jang, Y. N. Kang, J. S. Jang et al., Stereotactic body radiation therapy with or without transarterial chemoembolization for patients with primary hepatocellular carcinoma: preliminary analysis, BMC Cancer, vol.48, issue.1, p.351, 2008.
DOI : 10.1016/S0360-3016(00)00748-3

K. A. Goodman, E. A. Wiegner, K. E. Maturen, Z. Zhang, Q. Mo et al., Doseescalation study of single-fraction stereotactic body radiotherapy for liver malignancies

S. Stintzing, R. T. Hoffmann, V. Heinemann, M. Kufeld, and A. Muacevic, Frameless single-session robotic radiosurgery of liver metastases in colorectal cancer patients, European Journal of Cancer, vol.46, issue.6, pp.1026-1058
DOI : 10.1016/j.ejca.2010.01.008

W. Hara, B. W. Loo, J. , D. R. Goffinet, S. D. Chang et al., Excellent Local Control With Stereotactic Radiotherapy Boost After External Beam Radiotherapy in Patients With Nasopharyngeal Carcinoma, International Journal of Radiation Oncology*Biology*Physics, vol.71, issue.2, pp.71-393, 2008.
DOI : 10.1016/j.ijrobp.2007.10.027

K. W. Roh, J. S. Jang, M. S. Kim, D. I. Sun, B. S. Kim et al., Fractionated Stereotactic Radiotherapy as Reirradiation for Locally Recurrent Head and Neck Cancer, International Journal of Radiation Oncology*Biology*Physics, vol.74, issue.5, pp.74-1348, 2009.
DOI : 10.1016/j.ijrobp.2008.10.013

J. C. Rwigema, D. E. Heron, R. L. Ferris, M. Gibson, A. Quinn et al., Fractionated Stereotactic Body Radiation Therapy in the Treatment of Previously-Irradiated Recurrent Head and Neck Carcinoma, American Journal of Clinical Oncology, vol.33, issue.3, pp.286-93
DOI : 10.1097/COC.0b013e3181aacba5

M. J. Murphy and R. S. Cox, The accuracy of dose localization for an image-guided frameless radiosurgery system, Medical Physics, vol.23, issue.12, pp.2043-2052, 1996.
DOI : 10.1118/1.597771

S. D. Chang, W. Main, D. P. Martin, I. C. Gibbs, and M. P. Heilbrun, An analysis of the accuracy of the CyberKnife: a robotic frameless stereotactic radiosurgical system, Neurosurgery, vol.52, issue.1, pp.140-146, 2003.

C. Yu, W. Main, D. Taylor, G. Kuduvalli, M. L. Apuzzo et al., An Anthropomorphic Phantom Study of the Accuracy of CyberKnife Spinal Radiosurgery, Neurosurgery, vol.1, issue.5, pp.55-1138, 2004.
DOI : 10.1016/0360-3016(94)90076-0

C. Antypas and E. Pantelis, Performance evaluation of a CyberKnife?? G4 image-guided robotic stereotactic radiosurgery system, Physics in Medicine and Biology, vol.53, issue.17, pp.53-4697, 2008.
DOI : 10.1088/0031-9155/53/17/016

A. Muacevic, M. Staehler, C. Drexler, B. Wowra, M. Reiser et al., Technical description, phantom accuracy, and clinical feasibility for fiducial-free frameless real-time image-guided spinal radiosurgery, Journal of Neurosurgery: Spine, vol.55, issue.1, pp.303-315, 2006.
DOI : 10.1227/01.NEU.0000141080.54647.11

. D. Djajputra, G. La, I. , and Y. C. , SU-FF-T-112: Commissioning of a CyberKnife G4 System at Stanford University Medical Center, Medical Physics, vol.34, issue.6Part9, pp.2426-2433, 2007.
DOI : 10.1118/1.2760768

A. K. Ho, D. Fu, C. Cotrutz, S. L. Hancock, S. D. Chang et al., A STUDY OF THE ACCURACY OF CYBERKNIFE SPINAL RADIOSURGERY USING SKELETAL STRUCTURE TRACKING, Operative Neurosurgery, vol.55
DOI : 10.1227/01.NEU.0000141080.54647.11

P. Desai, C. P. Souza, and C. Medbery, ONS147-56; discussion ONS156. 43 Comprehensive CyberKnife QA A 2 Year Experience, Neurosurgery Med Phys, vol.60, issue.26, pp.33-2082, 2006.

C. Drexler and C. F. , Robot Specific Quality Assurance for the CyberKnife System in CyberKnife users meeting, 2010.

N. R. Ahmad, M. S. Huq, and B. W. Corn, Respiration-induced motion of the kidneys in whole abdominal radiotherapy: implications for treatment planning and late toxicity, Radiotherapy and Oncology, vol.42, issue.1
DOI : 10.1016/S0167-8140(96)01859-2

#. Senan, D. Suresh, . Ruysscher, and G. Dirk, Literature-based recommendations for treatment planning and execution in high-dose radiotherapy for lung cancer, Radiotherapy and Oncology, vol.71, issue.2, 2004.
DOI : 10.1016/j.radonc.2003.09.007

S. Senan, D. De-ruysscher, P. Giraud, R. Mirimanoff, and V. Budach, Literature-based recommendations for treatment planning and execution in high-dose radiotherapy for lung cancer, Radiotherapy and Oncology, vol.71, issue.2, pp.71-139, 2004.
DOI : 10.1016/j.radonc.2003.09.007

P. J. Keall, G. S. Mageras, J. M. Balter, R. S. Emery, K. M. Forster et al., The management of respiratory motion in radiation oncology

M. W. Kissick and T. R. Mackie, Task Group 76 Report on 'The management of respiratory motion in radiation oncology, Med. Phys. Med Phys, vol.33, issue.12, pp.3874-3900, 2006.

R. George, P. J. Keall, V. R. Kini, S. S. Vedam, J. V. Siebers et al., Quantifying the effect of intrafraction motion during breast IMRT planning and dose delivery, Medical Physics, vol.47, issue.9, pp.552-62, 2003.
DOI : 10.1088/0031-9155/47/19/302

P. W. Visser, S. S. Voet, and . Oei, Dosimetric consequences of tumor mobility in radiotherapy of stage I non-small cell lung cancer--an analysis of data generated using 'slow' CT scans, Radiother Oncol, issue.1, pp.61-93, 2001.

S. S. Schipper, A. Oei, and . Munne, Multiple "slow" CT scans for incorporating lung tumor mobility in radiotherapy planning, Int J Radiat Oncol Biol Phys, vol.51, issue.4, pp.932-939, 2001.

T. Aruga, J. Itami, M. Aruga, K. Nakajima, K. Shibata et al., Target volume definition for upper abdominal irradiation using CT scans obtained during inhale and exhale phases, International Journal of Radiation Oncology*Biology*Physics, vol.48, issue.2, pp.48-465, 2000.
DOI : 10.1016/S0360-3016(00)00610-6

R. W. Underberg, F. J. Lagerwaard, B. J. Slotman, J. P. Cuijpers, and S. Senan, Use of maximum intensity projections (MIP) for target volume generation in 4DCT scans for lung cancer, International Journal of Radiation Oncology*Biology*Physics, vol.63, issue.1, pp.63-253, 2005.
DOI : 10.1016/j.ijrobp.2005.05.045

H. Hof, K. K. Herfarth, M. Munter, M. Essig, M. Wannenmacher et al., Die Verwendung der Mehrzeilen-CT zur Bestimmung von atembedingten Lungentumorbewegungen bei der stereotaktischen Einzeitbestrahlung, Strahlentherapie und Onkologie, vol.179, issue.8, pp.179-542, 2003.
DOI : 10.1007/s00066-003-1070-8

K. K. Herfarth, J. Debus, F. Lohr, M. L. Bahner, P. Fritz et al., Extracranial stereotactic radiation therapy: set-up accuracy of patients treated for liver metastases, International Journal of Radiation Oncology*Biology*Physics, vol.46, issue.2
DOI : 10.1016/S0360-3016(99)00413-7

I. Lax, H. Blomgren, I. Naslund, and R. Svanstrom, Stereotactic Radiotherapy of Malignancies in the Abdomen: Methodological aspects, Acta Oncologica, vol.22, issue.6, pp.33-677, 1994.
DOI : 10.1016/0167-8140(91)90068-R

L. A. Dawson, K. K. Brock, S. Kazanjian, D. Fitch, C. J. Mcginn et al., The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy, Int J Radiat Oncol Biol Phys, issue.5, pp.51-1410, 2001.

R. Wagman, E. Yorke, E. Ford, P. Giraud, G. Mageras et al., Respiratory gating for liver tumors: use in dose escalation, International Journal of Radiation Oncology*Biology*Physics, vol.55, issue.3, pp.55-659, 2003.
DOI : 10.1016/S0360-3016(02)03941-X

J. Hanley, M. M. Debois, D. Mah, G. S. Mageras, A. Raben et al., Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation, International Journal of Radiation Oncology*Biology*Physics, vol.45, issue.3, pp.45-603, 1999.
DOI : 10.1016/S0360-3016(99)00154-6

D. Mah, J. Hanley, K. E. Rosenzweig, E. Yorke, L. Braban et al., Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer, International Journal of Radiation Oncology*Biology*Physics, vol.48, issue.4, pp.1175-85, 2000.
DOI : 10.1016/S0360-3016(00)00747-1

K. E. Rosenzweig, J. Hanley, D. Mah, G. Mageras, M. Hunt et al., The deep inspiration breath-hold technique in the treatment of inoperable non???small-cell lung cancer, International Journal of Radiation Oncology*Biology*Physics, vol.48, issue.1, pp.48-81, 2000.
DOI : 10.1016/S0360-3016(00)00583-6

L. A. Dawson, C. Eccles, J. P. Bissonnette, and K. K. Brock, Accuracy of daily image guidance for hypofractionated liver radiotherapy with active breathing control, International Journal of Radiation Oncology*Biology*Physics, vol.62, issue.4, pp.1247-52, 2005.
DOI : 10.1016/j.ijrobp.2005.03.072

J. W. Wong, M. B. Sharpe, D. A. Jaffray, V. R. Kini, J. M. Robertson et al., The use of active breathing control (ABC) to reduce margin for breathing motion, International Journal of Radiation Oncology*Biology*Physics, vol.44, issue.4, pp.911-920, 1999.
DOI : 10.1016/S0360-3016(99)00056-5

G. Starkschall, K. M. Forster, K. Kitamura, A. Cardenas, S. L. Tucker et al., Correlation of gross tumor volume excursion with potential benefits of respiratory gating, International Journal of Radiation Oncology*Biology*Physics, vol.60, issue.4, pp.1291-1298, 2004.
DOI : 10.1016/j.ijrobp.2004.07.707

S. S. Vedam, P. J. Keall, V. R. Kini, and R. Mohan, Determining parameters for respirationgated radiotherapy, Med Phys, issue.10, pp.28-2139, 2001.

R. I. Berbeco, S. Nishioka, H. Shirato, G. T. Chen, and S. B. Jiang, Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates, Physics in Medicine and Biology, vol.50, issue.16, pp.50-3655, 2005.
DOI : 10.1088/0031-9155/50/16/001

M. J. Murphy, Tracking moving organs in real time, Seminars in Radiation Oncology, vol.14, issue.1, pp.91-100, 2004.
DOI : 10.1053/j.semradonc.2003.10.005

A. Bel, O. Petrascu, I. Van-de-vondel, L. Coppens, N. Linthout et al., A computerized remote table control for fast on-line patient repositioning: Implementation and clinical feasibility, Medical Physics, vol.174, issue.2, pp.354-362, 2000.
DOI : 10.1016/S0360-3016(97)00304-0

D. Souza, W. D. , S. A. Naqvi, and C. X. Yu, Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study, Phys Med Biol, issue.17, pp.50-4021, 2005.

P. J. Keall, V. R. Kini, S. S. Vedam, and R. Mohan, Motion adaptive x-ray therapy: a feasibility study, Physics in Medicine and Biology, vol.46, issue.1, pp.1-10, 2001.
DOI : 10.1088/0031-9155/46/1/301

T. Neicu, H. Shirato, Y. Seppenwoolde, and S. B. Jiang, Synchronized moving aperture radiation therapy (SMART): average tumour trajectory for lung patients, Physics in Medicine and Biology, vol.48, issue.5, pp.48-587, 2003.
DOI : 10.1088/0031-9155/48/5/303

L. Papiez and D. Rangaraj, DMLC leaf-pair optimal control for mobile, deforming target, Medical Physics, vol.29, issue.1
DOI : 10.1118/1.1508109

H. Shirato, S. Shimizu, T. Kunieda, K. Kitamura, M. Van-herk et al., Physical aspects of a real-time tumor-tracking system for gated radiotherapy, International Journal of Radiation Oncology*Biology*Physics, vol.48, issue.4, pp.1187-95, 2000.
DOI : 10.1016/S0360-3016(00)00748-3

C. Ozhasoglu and M. J. Murphy, Issues in respiratory motion compensation during external-beam radiotherapy, International Journal of Radiation Oncology*Biology*Physics, vol.52, issue.5, pp.1389-99, 2002.
DOI : 10.1016/S0360-3016(01)02789-4

A. Schweikard, G. Glosser, M. Bodduluri, M. J. Murphy, and J. R. Adler, Robotic motion compensation for respiratory movement during radiosurgery, Bibliographie Comput Aided Surg, vol.158, issue.54, pp.263-77, 2000.

A. Schweikard, H. Shiomi, and J. Adler, Respiration tracking in radiosurgery, Medical Physics, vol.207, issue.6, pp.31-2738, 2004.
DOI : 10.1148/radiology.207.3.9609904

G. C. Sharp, S. B. Jiang, S. Shimizu, and H. Shirato, Prediction of respiratory tumour motion for real-time image-guided radiotherapy, Physics in Medicine and Biology, vol.49, issue.3, pp.425-465, 2004.
DOI : 10.1088/0031-9155/49/3/006

D. Ruan, J. A. Fessler, J. M. Balter, R. I. Berbeco, S. Nishioka et al., Inference of hysteretic respiratory tumor motion from external surrogates: a state augmentation approach, Physics in Medicine and Biology, vol.53, issue.11, pp.53-2923, 2008.
DOI : 10.1088/0031-9155/53/11/011

Y. Seppenwoolde, H. Shirato, K. Kitamura, S. Shimizu, M. Van-herk et al., Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy, International Journal of Radiation Oncology*Biology*Physics, vol.53, issue.4, pp.822-856, 2002.
DOI : 10.1016/S0360-3016(02)02803-1

G. Benchetrit, Breathing pattern in humans: diversity and individuality, Respiration Physiology, vol.122, issue.2-3, pp.123-129, 2000.
DOI : 10.1016/S0034-5687(00)00154-7

A. Hugelin and V. J. , Is the respiratory rhythm multistable in man respiratory control, in A Modeling Perspective, pp.353-359, 1989.

C. Patil, S. K. Sayers, and B. , Modeling the breath by breath variability in respiratory dataRespiratory Control, pp.343-352, 1989.

M. Murphy, J. J. Isaksson, M. , R. R. , S. Cora et al., Adaptive filtering to predict lung tumor breathing motion during imageguided radiation therapy Correlation Between Spatial Accuracy and Breathing Irregularities with Synchrony®, 16th International Congress on Computerassisted Radiology and Surgery CyberKnife® Users Meeting, 2002.

C. Cavedon, P. Francescon, S. Cora, G. Moschini, and P. Rossi, Performance of a Motion Tracking System During Cyberknife Robotic Radiosurgery, AIP Conference Proceedings, pp.1099-464, 2009.
DOI : 10.1063/1.3120074

C. Cavedon, P. Francescon, S. Cora, V. Santangelo, P. Scalchi et al., Analysis of Respiratory Signals From a Motion Tracking System Assessment of Lung Tumors treatement Accuracy Using CyberKnife Synchrony model, Med Phys, vol.36, p.2463, 2006.

K. Wong, SU-FF-J-40: Independent Measurement of CyberKnife Synchrony Accuracy Using Optical Tracking, Medical Physics, vol.32, issue.6Part4, pp.1928-1928, 2005.
DOI : 10.1118/1.1997586

M. Hoogeman, J. B. Prevost, J. Nuyttens, J. Poll, P. Levendag et al., Clinical Accuracy of the Respiratory Tumor Tracking System of the CyberKnife: Assessment by Analysis of Log Files, International Journal of Radiation Oncology*Biology*Physics, vol.74, issue.1, pp.74-297, 2009.
DOI : 10.1016/j.ijrobp.2008.12.041

Y. Seppenwoolde, R. I. Berbeco, S. Nishioka, H. Shirato, and B. Heijmen, Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: A simulation study, Medical Physics, vol.63, issue.7, pp.34-2774, 2007.
DOI : 10.1016/j.ijrobp.2005.04.024

E. Nioutsikou, Y. Seppenwoolde, J. R. Symonds-tayler, B. Heijmen, P. Evans et al., Dosimetric investigation of lung tumor motion compensation with a robotic respiratory tracking system: An experimental study, Medical Physics, vol.51, issue.4, pp.1232-1272, 2008.
DOI : 10.1088/0031-9155/51/6/006

A. Muacevic, C. Drexler, B. Wowra, A. Schweikard, A. Schlaefer et al., Technical Description, Phantom Accuracy, and Clinical Feasibility for Single-Session Lung Radiosurgery Using Robotic Image-Guided Real-time Respiratory Tumor Tracking, Technology in Cancer Research & Treatment, vol.6, issue.4, pp.321-329, 2007.
DOI : 10.1016/S0003-4975(02)04681-7

C. Cavedon, C. Chuang, S. Dieterich, C. Drexler, D. Taylor et al., A multi-institutional validation of Synchrony motion tracking accuracy using the Accuray Synchrony quality assurance motion generation tool -A work in progress, 6th Annual CyberKnife Users Meeting CyberKnife Society Evalution of Postional Accuracy in Moving Tumors Using a CIRS Dynamic Phantom, 2007.

S. Dieterich, T. , D. Chuang, C. Wong, K. Tang et al., The CyberKnife Synchrony Respiratory Tracking System: Evaluation of systematic targeting uncertainty, in white paper The CyberKnife Synchrony Respiratory Tracking System: Initial Evaluation of Nonlinear Correlation Model in white paper, 2004.

S. Dietrich and Y. S. , Motion Ranges Due to respiration and Respiratory Motion Characterisitcs, in Robotic RadioSurgery, 2007.

Y. Suh, S. Dieterich, B. Cho, and P. J. , An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients, Physics in Medicine and Biology, vol.53, issue.13, pp.53-3623, 2008.
DOI : 10.1088/0031-9155/53/13/016

E. A. Barnes, B. R. Murray, D. M. Robinson, L. J. Underwood, J. Hanson et al., Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration, International Journal of Radiation Oncology*Biology*Physics, vol.50, issue.4, pp.1091-1099, 2001.
DOI : 10.1016/S0360-3016(01)01592-9

S. C. Erridge, Y. Seppenwoolde, S. H. Muller, M. Van-herk, K. De-jaeger et al., Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer, Radiotherapy and Oncology, vol.66, issue.1, pp.66-75, 2003.
DOI : 10.1016/S0167-8140(02)00287-6

C. Plathow, S. Ley, C. Fink, M. Puderbach, W. Hosch et al., Analysis of intrathoracic tumor mobility during whole breathing cycle by dynamic MRI, International Journal of Radiation Oncology*Biology*Physics, vol.59, issue.4, pp.952-961, 2004.
DOI : 10.1016/j.ijrobp.2003.12.035

C. W. Stevens, R. F. Munden, K. M. Forster, J. F. Kelly, Z. Liao et al., Respiratory-driven lung tumor motion is independent of tumor size, tumor location, and pulmonary function, International Journal of Radiation Oncology*Biology*Physics, vol.51, issue.1, pp.51-62, 2001.
DOI : 10.1016/S0360-3016(01)01621-2

I. Suramo, M. Paivansalo, and V. Myllyla, Cranio-Caudal Movements of the Liver, Pancreas and Kidneys in Respiration, Acta Radiologica. Diagnosis, vol.135, issue.2, pp.129-160, 1984.
DOI : 10.1148/radiology.135.2.7367654

E. C. Ford, G. S. Mageras, E. Yorke, K. E. Rosenzweig, R. Wagman et al., Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging, International Journal of Radiation Oncology*Biology*Physics, vol.52, issue.2, pp.52-522, 2002.
DOI : 10.1016/S0360-3016(01)02681-5

M. J. Murphy, J. Balter, S. Balter, J. A. Bencomo, J. et al., The management of imaging dose during image-guided radiotherapy: Report of the AAPM Task Group 75, Medical Physics, vol.33, issue.10, pp.34-4041, 2007.
DOI : 10.1118/1.2349699

D. A. Low, W. B. Harms, S. Mutic, and J. A. Purdy, A technique for the quantitative evaluation of dose distributions, Medical Physics, vol.23, issue.5, pp.656-61, 1998.
DOI : 10.1118/1.597714

R. Grosjean, R. G. , C. Lorentz, C. Pasquier, P. A. Vuissoz et al., Dynamic platform for moving organ imaging, Medical Imaging 2006: Physics of Medical Imaging, 2006.
DOI : 10.1117/12.651702