. Lente, Des cartes basses résolution ou simplement une régression B-spline sur des données artéfactées devraient donc être suffisantes

L. Publications, D. Bonnemains, A. Mandry, B. Menini, J. Stos et al., Surface-length index: a novel index for rapid detection of right ventricles with abnormal ejection fraction using cardiac MRI, European Radiology, pp.1-9, 2013.

A. Hélène-clique, M. Menini, . Cheng, P. Hai-lai, J. Marie et al., Cartographie T1 du myocarde en respiration libre avec correction de mouvements. Oral Presentation, 2012.

A. Drme-+-10-]-marion-de-roquefeuil, J. Menini, P. Escanyé, J. Marie, and . Felblinger, Effect of physiological variation of heart rate on quantitative cardiac T2 mapping, Proceedings Scientific Meeting , International Society for Magnetic Resonance in Medeicine, 2010.

P. Ferry, A. Menini, . Slavin, . Glenn, . Stainsby et al., True T1 measurement of the myocardium with two techniques: SMART1map and variable flip angle, European Society of Magnetic Resonance in Medicine and Biology, 2013.

F. Gibiino, L. Sacolick, A. Menini, L. Landini, and F. Wiesinger, Free-breathing lung MRI using 3D radial zero-TE imaging. Oral Presentation, European Society of Magnetic Resonance in Medicine and Biology, 2013.

F. Gibiino, L. Sacolick, A. Menini, L. Landini, and F. Wiesinger, Free-breathing, zero-TE MR lung imaging. (submitted) Magnetic Resonance in Medicine, 2013.

V. Golkov, T. Spenger, A. Menini, M. Menzel, J. Cremers et al., Effects of low-rank constraints, line-process denoising and q-space compressed sensing on diffusion MR image reconstruction and kurtosis tensor estimation, European Society of Magnetic Resonance in Medicine and Biology, 2013.

A. Menini, H. Clique, M. Beaumont, J. Felblinger, and F. Odille, Correction de mouvement avec grics pour la cartographie T1 : validation sur fantôme, 2012.

A. Menini, H. Clique, M. Beaumont, J. Felblinger, and F. Odille, Motion correction for 3D T1 mapping using GRICS: phantom validation, Proceedings Scientific Meeting, International Society for Magnetic Resonance in Medicine, 2012.

A. Menini, P. Ferry, M. Beaumont, . Stainsby, . Jeffrey et al., Motion correction in post-injection dynamic cardiac t1 mapping: preliminary results, Journal of Cardiovascular Magnetic Resonance, vol.14, 2014.

A. Menini, F. Gibiino, F. Odille, L. Sacolick, and F. Wiesinger, Free-breathing, zero TE MRI for 3D respiratory motion quantification. Oral Presentation, European Society of Magnetic Resonance in Medicine and Biology, 2013.

A. Menini, . Slavin, . Glenn, . Stainsby, P. Jeffrey et al., Motion correction of multicontrast images applied to T1 and T2 quantification in cardiac MRI. e-Poster Presentation, European Society of Magnetic Resonance in Medicine and Biology, 2013.
URL : https://hal.archives-ouvertes.fr/hal-01730808

A. Menini, . Slavin, . Glenn, . Stainsby, P. Jeffrey et al., Motion correction of multicontrast images applied to T1 and T2 quantification in cardiac MRI. (under revision) Magnetic Resonance Materials in Physics, Biology and Medicine, 2013.
URL : https://hal.archives-ouvertes.fr/hal-01730808

A. Menini, P. Vuissoz, J. Felblinger, and F. Odille, Procédé de reconstruction d'un signal en imagerie médicale à partir de mesures expérimentales perturbées, et dispositif d'imagerie médicale mettent en oeuvre ce procédé, 2011.

A. Menini, P. Vuissoz, J. Felblinger, and F. Odille, Joint reconstruction of image and motion in MRI: implicit regularization using an adaptive 3D mesh. Medical Image Computing and Computer-Assisted Intervention MICCAI 2012, pp.264-271, 2012.

F. Odille, A. Menini, P. Vuissoz, L. Bonnemains, D. Mandry et al., Combining nonrigid motion correction and partial fourier for 3D high resolution cardiac imaging, Proceedings Scientific Meeting, International Society for Magnetic Resonance in Medeicine, 2012.

]. F. Bibliographie1, N. Bloch, E. M. Bloembergen, R. V. Purcell, and . Pound, Nuclear induction Relaxation effects in nuclear magnetic resonance absorption, Physical Review Physical Review, vol.70, issue.787, pp.460-474, 1946.

C. Paul and . Lauterbur, Image formation by induced local interactions: examples employing nuclear magnetic resonance, Nature, vol.242, issue.5394, pp.190-191, 1973.

P. Mansfield, Multi-planar image formation using NMR spin echoes, Journal of Physics C: Solid State Physics, vol.10, issue.3, p.55, 1977.
DOI : 10.1088/0022-3719/10/3/004

F. Odille, P. Vuissoz, P. Marie, and J. Felblinger, Generalized Reconstruction by Inversion of Coupled Systems (GRICS) applied to free-breathing MRI, Magnetic Resonance in Medicine, vol.176, issue.1, pp.146-157, 2008.
DOI : 10.1002/mrm.21623

URL : https://hal.archives-ouvertes.fr/inserm-00311698

J. Staubesand, Atlas der Anatomie des Menschen, 1988.

E. Choi, B. D. Rosen, V. R. Fernandes, R. T. Yan, K. Yoneyama et al., Prognostic value of myocardial circumferential strain for incident heart failure and cardiovascular events in asymptomatic individuals: the Multi-Ethnic Study of Atherosclerosis, European Heart Journal, vol.114, issue.30, pp.342354-2361, 2013.
DOI : 10.1161/CIRCULATIONAHA.105.588525

A. Dogui, N. Kachenoura, F. Frouin, M. Lefort, A. De-cesare et al., Consistency of aortic distensibility and pulse wave velocity estimates with respect to the Bramwell-Hill theoretical model: a cardiovascular magnetic resonance study, Journal of Cardiovascular Magnetic Resonance, vol.13, issue.1, p.13, 2011.
DOI : 10.1186/1532-429X-13-11

URL : https://hal.archives-ouvertes.fr/inserm-00668203

M. Labrousse, G. Hossu, G. Calmon, A. Chays, J. Felblinger et al., In vivo characterization of the vestibulo-cochlear nerve motion by MRI, NeuroImage, vol.59, issue.2, pp.943-949, 2012.
DOI : 10.1016/j.neuroimage.2011.08.058

J. M. Froehlich, M. A. Patak, C. F. Constantin-von-weymarn, C. L. Juli, K. Zollikofer et al., Small bowel motility assessment with magnetic resonance imaging, Journal of Magnetic Resonance Imaging, vol.19, issue.4, pp.370-375, 2005.
DOI : 10.1007/BF01079785

E. M. Haacke, R. W. Brown, M. R. Thompson, and R. Venkatesan, Magnetic Resonance Imaging: Physical Principles and Sequence Design, 1999.

M. A. Bernstein, K. F. King, and X. Zhou, Handbook of MRI Pulse Sequences, 2004.

N. G. Bellenger, M. I. Burgess, S. G. Ray, A. Lahiri, A. J. Coats et al., Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance. Are they interchangeable?, European Heart Journal, vol.21, issue.16, pp.1387-1396, 2000.
DOI : 10.1053/euhj.2000.2011

A. Menys, D. Atkinson, F. Odille, A. Ahmed, M. Novelli et al., Quantified terminal ileal motility during MR enterography as a potential biomarker of Crohn???s disease activity: a preliminary study, European Radiology, vol.19, issue.1, pp.222494-2501, 2012.
DOI : 10.1007/s00330-008-1293-2

V. Parthasarathy, J. L. Prince, M. Stone, E. Z. Murano, and M. Nessaiver, Measuring tongue motion from tagged cine-MRI using harmonic phase (HARP) processing, The Journal of the Acoustical Society of America, vol.121, issue.1, pp.491-504, 2007.
DOI : 10.1121/1.2363926

M. D. Abràmoff, P. G. Ad, G. H. Van-gils, M. P. Jansen, and . Mourits, MRI dynamic color mapping: A new quantitative technique for imaging soft tissue motion in the orbit, Investigative Ophthalmology & Visual Science, issue.11, pp.413256-3260, 2000.

T. Ebbers, Flow imaging: Cardiac applications of 3D cine phase-contrast MRI. Current Cardiovascular Imaging Reports, pp.127-133, 2011.

A. P. Dempster, N. M. Laird, and D. B. Rubin, Maximum likelihood from incomplete data via the EM algorithm, Journal of the Royal Statistical Society. Series B (Methodological), pp.1-38, 1977.

S. Geman and D. Geman, Stochastic relaxation, gibbs distributions, and the bayesian restoration of images, IEEE Transactions on Pattern Analysis and Machine Intelligence, issue.6, pp.6721-741, 1984.

L. Louis and . Scharf, Statistical signal processing, 1991.

A. N. Tikhonov, Numerical Methods for the Solution of Ill-Posed Problems, 1995.
DOI : 10.1007/978-94-015-8480-7

C. R. Vogel and M. E. Oman, Fast, robust total variation-based reconstruction of noisy, blurred images, IEEE Transactions on Image Processing, vol.7, issue.6, pp.813-824, 1998.
DOI : 10.1109/83.679423

E. J. Candes and M. B. Wakin, An Introduction To Compressive Sampling, IEEE Signal Processing Magazine, vol.25, issue.2, pp.21-30, 2008.
DOI : 10.1109/MSP.2007.914731

M. Lustig, D. Donoho, and J. M. Pauly, Sparse MRI: The application of compressed sensing for rapid MR imaging, Magnetic Resonance in Medicine, vol.170, issue.6, pp.1182-1195, 2007.
DOI : 10.1002/mrm.21391

M. Bertero and P. Boccacci, Introduction to Inverse Problems in Imaging, 2010.
DOI : 10.1887/0750304359

E. Maeland, On the comparison of interpolation methods, IEEE Transactions on Medical Imaging, vol.7, issue.3, pp.213-217, 1988.
DOI : 10.1109/42.7784

C. E. Duchon, Lanczos Filtering in One and Two Dimensions, Journal of Applied Meteorology, vol.18, issue.8, pp.1016-1022, 1979.
DOI : 10.1175/1520-0450(1979)018<1016:LFIOAT>2.0.CO;2

E. Kerrien and M. Berger, Outils d'imagerie multimodalité pour la neuroradiologie interventionnelle, 2000.

S. Baker and I. Matthews, Lucas-Kanade 20 Years On: A Unifying Framework, International Journal of Computer Vision, vol.56, issue.3, pp.221-255, 2004.
DOI : 10.1023/B:VISI.0000011205.11775.fd

G. P. Penney, J. Weese, J. A. Little, P. Desmedt, D. Hill et al., A comparison of similarity measures for use in 2-D-3-D medical image registration, IEEE Transactions on Medical Imaging, vol.17, issue.4, pp.586-595, 1998.
DOI : 10.1109/42.730403

M. Avriel, Nonlinear Programming: Analysis and Methods, 2003.

X. Pennec, P. Cachier, and N. Ayache, Understanding the ???Demon???s Algorithm???: 3D Non-rigid Registration by Gradient Descent, Medical Image Computing and Computer-Assisted Intervention MICCAI 99, number 1679 in Lecture Notes in Computer Science, pp.597-605, 1999.
DOI : 10.1007/10704282_64

C. Per, D. Hansen, O. Prost, and . Leary, The use of the l-curve in the regularization of discrete ill-posed problems, SIAM Journal on Scientific Computing, vol.14, issue.6, pp.1487-1503, 1993.

D. Rueckert, L. Sonoda, C. Hayes, D. L. Hill, M. Leach et al., Nonrigid registration using free-form deformations: application to breast MR images, IEEE Transactions on Medical Imaging, vol.18, issue.8, pp.712-721, 1999.
DOI : 10.1109/42.796284

C. B. Barber, P. David, H. Dobkin, and . Huhdanpaa, The quickhull algorithm for convex hulls, ACM Transactions on Mathematical Software, vol.22, issue.4, pp.469-483, 1996.
DOI : 10.1145/235815.235821

B. Fernandez, J. Oster, M. Lohezic, D. Mandry, O. Pietquin et al., Adaptive black blood fast spin echo for end-systolic rest cardiac imaging, Magnetic Resonance in Medicine, vol.42, issue.6, pp.1760-1771, 2010.
DOI : 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO;2-S

URL : https://hal.archives-ouvertes.fr/inserm-00605433

C. Albert, F. C. Van-rossum, M. Visser, . Sprenger, J. Machiel et al., Evaluation of magnetic resonance imaging for determination of left ventricular ejection fraction and comparison with angiography, The American Journal of Cardiology, vol.62, issue.9, pp.628-633, 1988.

F. Nael, S. Osman, E. Sampath, J. L. Atalar, and . Prince, Imaging longitudinal cardiac strain on short-axis images using strain-encoded MRI, Magnetic Resonance in Medicine, vol.46, issue.2, pp.324-334, 2001.

C. Tsoumpas, C. Buerger, A. P. King, P. Mollet, V. Keereman et al., Fast generation of 4D PET-MR data from real dynamic MR acquisitions, Physics in Medicine and Biology, vol.56, issue.20, p.566597, 2011.
DOI : 10.1088/0031-9155/56/20/005

P. David, I. J. Madio, and . Lowe, Ultra-fast imaging using low flip angles and fids, Magnetic Resonance in Medicine, vol.34, issue.4, pp.525-529, 1995.

T. Makela, P. Clarysse, O. Sipila, N. Pauna, Q. Cuong-pham et al., A review of cardiac image registration methods, IEEE Transactions on Medical Imaging, vol.21, issue.9, pp.1011-1021, 2002.
DOI : 10.1109/TMI.2002.804441

W. Shi, X. Zhuang, L. Pizarro, W. Bai, H. Wang et al., Registration Using Sparse Free-Form Deformations, Medical Image Computing and Computer-Assisted Intervention -MICCAI 2012, number 7511 in Lecture Notes in Computer Science, pp.659-666, 2012.
DOI : 10.1007/978-3-642-33418-4_81

URL : https://link.springer.com/content/pdf/10.1007%2F978-3-642-33418-4_81.pdf

L. Axel, Tagged MRI-Based Studies of Cardiac Function, Functional Imaging and Modeling of the Heart, number 2674 in Lecture Notes in Computer Science, pp.1-7, 2003.
DOI : 10.1007/3-540-44883-7_1

J. G. Pipe, Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging, Magnetic Resonance in Medicine, vol.38, issue.5, pp.963-969, 1999.
DOI : 10.1002/mrm.1910380418

A. Edward-brian-welch, R. C. Manduca, H. A. Grimm, C. R. Ward, and . Jack-jr, Spherical navigator echoes for full 3D rigid body motion measurement in MRI, Magnetic Resonance in Medicine, vol.20, issue.1, pp.32-41, 2002.
DOI : 10.1002/mrm.1910350312

C. S. Anja, J. H. Brau, and . Brittain, Generalized self-navigated motion detection technique: Preliminary investigation in abdominal imaging, Magnetic Resonance in Medicine, vol.55, issue.2, pp.263-270, 2006.

F. Odille, S. Uribe, P. G. Batchelor, C. Prieto, T. Schaeffter et al., Model-based reconstruction for cardiac cine MRI without ECG or breath holding, Magnetic Resonance in Medicine, vol.61, issue.5, pp.1247-1257, 2010.
DOI : 10.1002/mrm.22312

URL : https://hal.archives-ouvertes.fr/inserm-00605123

H. Clique, H. Cheng, P. Marie, J. Felblinger, and M. Beaumont, 3D myocardial t1 mapping at 3T using variable flip angle method: Pilot study, Magnetic Resonance in Medicine, 2013.
URL : https://hal.archives-ouvertes.fr/hal-01726409

J. Oster, O. Pietquin, M. Kraemer, and J. Felblinger, Bayesian framework for artifact reduction on ECG IN MRI, 2010 IEEE International Conference on Acoustics, Speech and Signal Processing, pp.489-492, 2010.
DOI : 10.1109/ICASSP.2010.5495684

URL : https://hal.archives-ouvertes.fr/hal-00476479

P. Klaas, M. Pruessmann, M. B. Weiger, P. Scheidegger, and . Boesiger, SENSE: sensitivity encoding for fast MRI, Magnetic Resonance in Medicine, vol.42, issue.5, pp.952-962, 1999.

A. Mark, P. M. Griswold, R. M. Jakob, M. Heidemann, V. Nittka et al., Generalized autocalibrating partially parallel acquisitions (GRAPPA), Magnetic Resonance in Medicine, vol.47, issue.6, pp.1202-1210, 2002.

D. C. Noll, D. G. Nishimura, and A. Macovski, Homodyne detection in magnetic resonance imaging, IEEE Transactions on Medical Imaging, vol.10, issue.2, pp.154-163, 1991.
DOI : 10.1109/42.79473

B. Madore, UNFOLD-SENSE: A parallel MRI method with self-calibration and artifact suppression, Magnetic Resonance in Medicine, vol.50, issue.2, pp.310-320, 2004.
DOI : 10.1002/mrm.1910350415

J. Tsao, P. Boesiger, and K. P. Pruessmann, k-t BLAST andk-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations, Magnetic Resonance in Medicine, vol.46, issue.5, pp.1031-1042, 2003.
DOI : 10.1002/mrm.1237

L. David and . Donoho, For most large underdetermined systems of linear equations the minimal l1-norm solution is also the sparsest solution, Communications on Pure and Applied Mathematics, vol.59, issue.6, pp.797-829, 2006.

E. J. Candes, J. Romberg, and T. Tao, Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information, IEEE Transactions on Information Theory, vol.52, issue.2, pp.489-509, 2006.
DOI : 10.1109/TIT.2005.862083

T. Paul, B. A. Gurney, D. G. Hargreaves, and . Nishimura, Design and analysis of a practical 3D cones trajectory, Magnetic Resonance in Medicine, vol.55, issue.3, pp.575-582, 2006.

S. Thesen, O. Heid, E. Mueller, and L. R. Schad, Prospective acquisition correction for head motion with image-based tracking for real-time fMRI, Magnetic Resonance in Medicine, vol.34, issue.3, pp.457-465, 2000.
DOI : 10.1109/34.387491

P. Kellman, C. Chefd, C. H. Lorenz, C. Mancini, A. E. Arai et al., Fully automatic, retrospective enhancement of real-time acquired cardiac cine MR images using image-based navigators and respiratory motion-corrected averaging, Magnetic Resonance in Medicine, vol.51, issue.4, pp.771-778, 2008.
DOI : 10.1148/radiology.203.3.9169696

P. G. Batchelor, D. Atkinson, P. Irarrazaval, D. L. Hill, J. Hajnal et al., Matrix description of general motion correction applied to multishot images, Magnetic Resonance in Medicine, vol.21, issue.5, pp.1273-1280, 2005.
DOI : 10.1002/mrm.20656

T. Schäffter, I. C. Volker-rasche, and . Carlsen, Motion compensated projection reconstruction, Magnetic Resonance in Medicine, vol.1001, issue.5, pp.954-963, 1999.
DOI : 10.1117/12.969046

M. Usman, D. Atkinson, F. Odille, C. Kolbitsch, G. Vaillant et al., Motion corrected compressed sensing for free-breathing dynamic cardiac MRI, Magnetic Resonance in Medicine, vol.18, issue.2, pp.504-516, 2013.
DOI : 10.1109/42.774166

URL : https://hal.archives-ouvertes.fr/hal-01718122

D. Manke, K. Nehrke, and P. Börnert, Novel prospective respiratory motion correction approach for free-breathing coronary MR angiography using a patient-adapted affine motion model, Magnetic Resonance in Medicine, vol.214, issue.1, pp.122-131, 2003.
DOI : 10.1148/radiology.214.1.r00ja41283

J. R. Mcclelland, D. J. Hawkes, T. Schaeffter, and A. P. King, Respiratory motion models: A review, Medical Image Analysis, vol.17, issue.1, pp.19-42, 2013.
DOI : 10.1016/j.media.2012.09.005

F. Odille, Imagerie Adaptative en IRM : Utilisation des Informations de Mouvements Physiologiques pour l?Optimisation des Processus d?Acquisition et de Reconstruction, 2007.

P. Vuissoz, F. Odille, B. Fernandez, M. Lohezic, A. Benhadid et al., Free-breathing imaging of the heart using 2D cine-GRICS (generalized reconstruction by inversion of coupled systems) with assessment of ventricular volumes and function, Journal of Magnetic Resonance Imaging, vol.11, issue.2, pp.340-351, 2012.
DOI : 10.1186/1532-429X-11-19

L. I. Rudin, S. Osher, and E. Fatemi, Nonlinear total variation based noise removal algorithms, Physica D: Nonlinear Phenomena, vol.60, issue.1-4, pp.1-4259, 1992.
DOI : 10.1016/0167-2789(92)90242-F

S. R. Arridge, M. Schweiger, M. Hiraoka, and D. T. Delpy, A finite element approach for modeling photon transport in tissue, Medical Physics, vol.20, issue.2, pp.299-299, 1993.
DOI : 10.1118/1.597069

A. Joshi, W. Bangerth, and E. Sevick-muraca, Adaptive finite element based tomography for fluorescence optical imaging in tissue, Optics Express, vol.12, issue.22, pp.5402-5417, 2004.
DOI : 10.1364/OPEX.12.005402

M. Filipovic, P. Vuissoz, A. Codreanu, M. Claudon, and J. Felblinger, Motion compensated generalized reconstruction for free-breathing dynamic contrast-enhanced MRI, Magnetic Resonance in Medicine, vol.54, issue.3, pp.812-822, 2011.
DOI : 10.1002/mrm.20686

C. Meyer, P. Vuissoz, D. Mandry, and J. Felblinger, First attempt to motion corrected flow encoding using free-breathing phase-contrast CINE MRI, Journal of Cardiovascular Magnetic Resonance, vol.14, issue.Suppl 1, pp.53-22376549, 2012.
DOI : 10.1186/1532-429X-14-S1-W53

URL : https://hal.archives-ouvertes.fr/inserm-00665426

A. Codreanu, F. Odille, E. Aliot, P. Marie, I. Magnin-poull et al., Electroanatomic characterization of post-infarct ScarsComparison with 3-dimensional myocardial scar reconstruction based on magnetic resonance imaging, Journal of the American College of Cardiology, issue.10, pp.52839-842, 2008.

N. Mewton, C. Y. Liu, P. Croisille, D. Bluemke, and J. A. Lima, Assessment of Myocardial Fibrosis With Cardiovascular Magnetic Resonance, Journal of the American College of Cardiology, vol.57, issue.8, pp.891-903, 2011.
DOI : 10.1016/j.jacc.2010.11.013

F. Kober, I. Iltis, M. Izquierdo, M. Desrois, D. Ibarrola et al., High-resolution myocardial perfusion mapping in small animals in vivo by spin-labeling gradient-echo imaging, Magnetic Resonance in Medicine, vol.40, issue.1, pp.62-67, 2004.
DOI : 10.1016/S0735-1097(02)02033-8

J. Cai, T. S. Hatsukami, M. S. Ferguson, R. Small, N. L. Polissar et al., Classification of Human Carotid Atherosclerotic Lesions With In Vivo Multicontrast Magnetic Resonance Imaging, Circulation, vol.106, issue.11, pp.1368-1373, 2002.
DOI : 10.1161/01.CIR.0000028591.44554.F9

P. Kellman, Y. Chung, O. P. Simonetti, E. R. Mcveigh, and A. E. Arai, Multicontrast delayed enhancement provides improved contrast between myocardial infarction and blood pool, Journal of Magnetic Resonance Imaging, vol.6, issue.5, pp.605-613, 2005.
DOI : 10.1016/0022-2364(82)90042-7

R. Daniel, A. Messroghli, S. Radjenovic, D. M. Kozerke, M. U. Higgins et al., Modified look-locker inversion recovery (MOLLI) for high-resolution t1 mapping of the heart, Magnetic Resonance in Medicine, vol.52, issue.1, pp.141-146, 2004.

T. Song, J. A. Stainsby, V. B. Ho, M. N. Hood, and G. S. Slavin, Flexible cardiac T1 mapping using a modified look-locker acquisition with saturation recovery, Magnetic Resonance in Medicine, vol.23, issue.Suppl 3, pp.622-627, 2012.
DOI : 10.1007/s10334-010-0202-2

S. Glenn, J. A. Slavin, and . Stainsby, True t1 mapping with SMART1Map (saturation method using adaptive recovery times for cardiac t1 mapping): a comparison with MOLLI, Journal of Cardiovascular Magnetic Resonance, vol.15, issue.1, p.3, 2013.

J. A. Stainsby and G. S. Slavin, Myocardial T1 mapping using SMART1Map: initial in vivo experience, Journal of Cardiovascular Magnetic Resonance, vol.15, issue.Suppl 1, p.13, 2013.
DOI : 10.1186/1532-429X-15-S1-P13

P. Marion-de-roquefeuil, J. Vuissoz, J. Escanyé, and . Felblinger, Effect of physiological Heart Rate variability on quantitative T2 measurement with ECG-gated Fast Spin Echo (FSE) sequence and its retrospective correction, Magnetic Resonance Imaging, vol.31, issue.9
DOI : 10.1016/j.mri.2013.06.006

F. Odille, N. Cîndea, and D. Mandry, Generalized MRI reconstruction including elastic physiological motion and coil sensitivity encoding, Magnetic Resonance in Medicine, vol.33, issue.6, pp.1401-1411, 2008.
DOI : 10.1148/radiology.173.1.2781017

URL : https://hal.archives-ouvertes.fr/inserm-00311700

E. Plenge, D. H. Poot, M. Bernsen, G. Kotek, G. Houston et al., Super-resolution methods in MRI: Can they improve the trade-off between resolution, signal-to-noise ratio, and acquisition time?, Magnetic Resonance in Medicine, vol.2007, issue.6, pp.681983-1993, 2012.
DOI : 10.1155/2007/43953

J. P. Haldar, V. J. Wedeen, M. Nezamzadeh, G. Dai, M. W. Weiner et al., Improved diffusion imaging through SNR-enhancing joint reconstruction, Magnetic Resonance in Medicine, vol.29, issue.1, pp.277-289, 2013.
DOI : 10.1016/j.mri.2011.03.008

URL : http://europepmc.org/articles/pmc3407310?pdf=render

J. Huang, C. Chen, and L. Axel, Fast multi-contrast MRI reconstruction, Medical Image Computing and Computer-Assisted Intervention - MICCAI 2012, pp.281-288, 2012.
DOI : 10.1007/978-3-642-33415-3_35

URL : http://ranger.uta.edu/%7Ehuang/papers/MICCAI12_MRI.pdf

B. Bilgic, K. Vivek, E. Goyal, and . Adalsteinsson, Multi-contrast reconstruction with Bayesian compressed sensing, Magnetic Resonance in Medicine, vol.62, issue.6, pp.1601-1615, 2011.
DOI : 10.1002/mrm.22161

D. Ma, V. Gulani, N. Seiberlich, K. Liu, J. L. Sunshine et al., Magnetic resonance fingerprinting, Nature, vol.211, issue.7440, pp.495187-192, 2013.
DOI : 10.2307/2532051

M. Lohézic, Reconstructions Adaptatives pour l'Imagerie par Résonance Magnétique des Organes en Mouvement, 2011.

Y. Pierre, M. Marie, J. P. Angioi, J. M. Carteaux, S. Escanye et al., Detection and prediction of acute heart transplant rejection with the myocardial t2 determination provided by a black-blood magnetic resonance imaging sequence, J Am Coll Cardiol, vol.37, issue.3, pp.825-831, 2001.

M. D. Cerqueira, Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the Heart: A Statement for Healthcare Professionals From the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association, Circulation, vol.105, issue.4, pp.539-542, 2002.
DOI : 10.1161/hc0402.102975

M. D. Hãoerlimann and D. Griffin, Spin Dynamics of Carr???Purcell???Meiboom???Gill-like Sequences in Grossly Inhomogeneous B0 and B1 Fields and Application to NMR Well Logging, Journal of Magnetic Resonance, vol.143, issue.1, pp.120-135, 2000.
DOI : 10.1006/jmre.1999.1967

H. Cheng, A. Graham, and . Wright, Rapid high-resolutionT1 mapping by variable flip angles: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity, Magnetic Resonance in Medicine, vol.9, issue.3, pp.566-574, 2006.
DOI : 10.1016/0022-2364(87)90265-4

L. I. Sacolick, L. Sun, M. W. Vogel, W. T. Dixon, and I. Hancu, Fast radiofrequency flip angle calibration by Bloch-Siegert shift, Magnetic Resonance in Medicine, vol.63, issue.5, pp.1333-1338, 2011.
DOI : 10.1002/jmri.22018

Y. Huang, S. Majumdar, H. K. Genant, P. Wing, K. R. Chan et al., Quantitative MR relaxometry study of muscle composition and function in duchenne muscular dystrophy, Journal of Magnetic Resonance Imaging, vol.356, issue.1, pp.59-64, 1994.
DOI : 10.1148/radiology.169.2.3175009