P. D. Gatehouse, D. N. Firmin-]-j, T. J. Boxerman, E. R. Mosher, E. Mcveigh et al., The cardiovascular magnetic resonance machine: hardware and software requirementsAdvanced MR imaging techniques for evaluation of the heart and great vesselsCardiac imagingCardiac MR imaging: a guide for the beginner, Herz Radiographics Radiology Radiographics, vol.255, issue.19, pp.317-347, 1998.

J. P. Earls, V. B. Ho, T. K. Foo, E. Castillo, and S. D. Flamm, Cardiac MRI: Recent progress and continued challenges, Journal of Magnetic Resonance Imaging, vol.103, issue.2, pp.111-138, 2002.
DOI : 10.1161/01.CIR.103.21.2535

URL : http://onlinelibrary.wiley.com/doi/10.1002/jmri.10154/pdf

D. Didier, O. Ratib, R. Lerch, B. Friedli-allen, G. Polizzi et al., How to perform cardiac MR imagingNew cardiac imaging technologies Future role in ischemic heart diseaseIdentification of EEG events in the MR scanner: the problem of pulse artifact and a method for its subtractionECG artifacts during intraoperative high-field MRI scanningStatic magnetic field effects on human subjects related to magnetic resonance imaging systemsRestoration of electrophysiological signals distorted by inductive effects of magnetic field gradients during MR sequencesMinimizing interference from magnetic resonance imagers during electrocardiographyRestoration of MR-induced artifacts in simultaneously recorded MR/EEG data[ECG changes caused by the effect of static magnetic fields of nuclear magnetic resonance tomography using magnets with a field power of 0.5 to 4MRI: Principles and ArtifactsComparison of different cardiac MRI sequences at 1.5 T/3.0 T with respect to signal-to-noise and contrast-to-noise ratios -initial experienceOptimization of signal behavior in the transition to driven equilibrium in steady-state free precession sequencesK-Space sampling strategiesProspective navigator gating with a dual acceptance window technique to reduce respiratory motion artifacts in 3D MR coronary angiographyProspective navigator correction of image position for coronary MR angiographyA comparison of prospective and retrospective respiratory navigator gating in 3D MR coronary angiographyPC-based system for retrospective cardiac and respiratory gating of NMR dataRetrospective cardiac gating: a review of technical aspects and future directions, MR imagingProbability, Random Variables and Stochastic Processes26] B. Sievers, M. Addo, S. Kirchberg, A. Bakan, B. John-Puthenveettil, U. Franken, pp.1279-99, 1989.

. Trappe, Impact of the ECG gating method on ventricular volumes and ejection fractions assessed by cardiovascular magnetic resonance imaging, J Cardiovasc Magn Reson, vol.7, pp.441-447, 2005.

O. Muller, T. A. Henriksen, ]. J. Spraggins30, R. Malmivuo, . Plonsey31-]-s et al., Wireless retrospective gating: application to cine cardiac imagingReview of Medical PhysiologyTaschenatlas der PhysiologieReference Manual for Magnetic Resonance Safety, Implants & DevicesMagnetic Resonance Procedures: Health Effects and Safety[Patient monitoring and safety aspects in magnetic resonance imaging examinations]Sedation and monitoring of paediatric patients undergoing open low-field MRIThe AAPM/RSNA physics tutorial for residents. MR imaging safety considerationsAdvances in pediatric electrophysiology, Comparison between retrospective gating and ECG triggering in magnetic resonance velocity mapping Los Angeles: Bracco38] Medical Device Agency (MDA): 2002, Guidelines for Magnetic Resonance Equipment in Clinical Use [39]ASA monitoring standards and magnetic resonance imagingMonitoring of anesthesia during magnetic resonance imaging]", Ugeskr Laeger41] L. M. Bevilacqua and C. I. Berul, pp.533-540, 1990.

R. Abächerli, C. Pasquier, F. Odille, M. Kraemer, J. J. Schmid et al., Suppression of MR gradient artefacts on electrophysiological signals based on an adaptive real-time filter with LMS coefficient updatesArtefact mimicking tachycardia during magnetic resonance imaging in a patient with an implantable loop recorderNovel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions Medical electrical equipement -Part 2: Particular requirements for the safety of electrocardiographic monitoring equipment, Medical electrical equipment -Part 2-51: Particular requirements for safety, including essential performance, of recording and analysing single channel and multichannel electrocardiographs, pp.41-50, 1994.

A. Aami, E. J. Felblinger, C. Lehmann, and C. Boesch, Testing and reporting performance results of cardiac rhythm and ST- Segment measurement algorithmsElectrocardiogram acquisition during MR examinations for patient monitoring and sequence triggering, Magn Reson Med, vol.32, issue.53, pp.523-532, 1994.

J. M. Chia, S. E. Fischer, S. A. Wickline, C. H. Lorenz56-]-r, S. E. Setser et al., Performance of QRS detection for cardiac magnetic resonance imaging with a novel vectorcardiographic triggering methodQuantification of left ventricular function with magnetic resonance images acquired in real time, J Magn Reson Imaging J Magn Reson Imaging, vol.1257, issue.1258, pp.678-88, 2000.

P. Lanzer, E. H. Botvinick, N. B. Schiller, L. E. Crooks, M. Arakawa et al., Cardiac imaging using gated magnetic resonanceECGsynchronized cardiac MR imaging: method and evaluation, Radiology Radiology, vol.15060, issue.155, pp.121-128, 1984.

R. Rokey, R. E. Wendt, D. L. Johnston, A. A. Damji, R. E. Snyder et al., RF interference suppression in a cardiac synchronization system operating in a high magnetic field NMR imaging systemSuppression of radiofrequency interference in cardiac gated MRI: a simple designA system for cardiac and respiratory gating of a magnetic resonance imagera cardiac gating device for mri system" presented at 11th annual meetingElectrocardiographic gating and monitoring in NMR imagingAn electrocardiographrespiration gating device for MR studiesSynchronization device for electrocardiography-gated echo-planar imagingThe lever-coil: a simple, inexpensive sensor for respiratory and cardiac motion in MRI experimentsFiber-optic stethoscope: a cardiac monitoring and gating system for magnetic resonance microscopyProspective MR signal-based cardiac triggeringAutomated rectilinear self-gated cardiac cine imagingSelf-gated cardiac cine MRIImaging of myocardial infarction for diagnosis and intervention using real-time interactive MRI without ECG-gating or breath-holdingTriggered real-time MRI and cardiac applications, 75] M. Weiger, K. P. Pruessmann, and P. Boesiger, "Cardiac real-time imaging using SENSE. SENSitivity Encoding scheme, pp.240-245, 1988.

M. Bydder, D. Atkinson, D. J. Larkman, D. L. Hill, J. V. Hajnal et al., SMASH navigators[3D motion adapted gating: a new navigator technique to shorten the acquisition time for coronary MRA]Floating navigator echo (FNAV) for in-plane 2D translational motion estimation, Magn Reson Med Rofo Magn Reson Med, vol.4979, issue.51, pp.493-500, 2003.

K. Mcleish, S. Kozerke, W. R. Crum, and D. L. Hill, Free-breathing radial acquisitions of the heart, Magnetic Resonance in Medicine, vol.44, issue.5, pp.1127-1162, 0198.
DOI : 10.1148/radiology.203.3.9169696

J. T. Su, T. Chung, R. Muthupillai, R. H. Pignatelli, G. C. Kung et al., Usefulness of real-time navigator magnetic resonance imaging for evaluating coronary artery origins in pediatric patientsBurn associated with temperature monitoring during magnetic resonance imagingBurns associated with electrocardiographic monitoring during magnetic resonance imaging, Am J Cardiol Anesthesiology Burns, vol.9583, issue.22, pp.679-82, 1992.

E. Kanal, F. G. Shellock, M. V. Knopp, M. Essig, J. Debus et al., Hazardous situation in the MR bore: induction in ECG leads causes fireBurns associated with the use of monitoring equipment during MR proceduresA third-degree burn associated with external cardiac pacing in a five-year-old boyRF-induced temperature elevation along metallic wires in clinical magnetic resonance imaging: influence of diameter and lengthInvestigation of the factors responsible for burns during MRI8.0-Tesla human MR system: temperature changes associated with radiofrequency-induced heating of a head phantom[Safety considerations to avoid currentinduced skin burns in MRI proceduresOn the heating of linear conductive structures as guide wires and catheters in interventional MRIRF heating due to conductive wires during MRI depends on the phase distribution of the transmit fieldA method for removing imaging artifact from continuous EEG recorded during functional MRIReduction of ECG and gradient related artifacts in simultaneously recorded human EEG/MRI dataMotion and ballistocardiogram artifact removal for interleaved recording of EEG and EPs during MRI, Recording of electrical brain activity in a magnetic resonance environment: distorting effects of the static magnetic field, pp.585-572, 1990.

D. Weishaupt, V. D. Köchli, B. Marincek, D. W. Mcrobbie, E. A. Moore et al., Wie funktioniert MRI? Eine Einführung in Physik und Funktionsweise der Magnetresonanzbildgebung, MRI, From Picture to Proton, 2001.

A. Desgrez and J. , Bittoun, and I. Idy-Peretti, "1. Bases physiques de l'IRM, 1995.

M. A. Brown and R. C. Semelka, MRI: Basic Principles and Applications, 2003.
DOI : 10.1002/0471467936

V. Kuperman, Magnetic Resonance Imaging, Physical Principles and Applications, 2000.

D. Dpk, Formeln und Tafeln, 1988.

H. Morneburg, Bildgebende Systeme für die medizinische Diagnostik, 1995.

J. D. Bronzino, The Biomedical Engineering Handbook, Boca Raton, 1995.

E. Lüscher, Experimentalphysik II, Elektromagnetische Vorgänge, Mannheim: Bibliographisches Institut AG, 1966.

J. F. Schenck, The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds, Medical Physics, vol.23, issue.6, pp.815-50, 1996.
DOI : 10.1118/1.597854

P. W. Macfarlane, T. D. Veitch, and . Lawrie, Theory and Pratice in Health and Disease, 1989.

M. Joffre, Canaux ioniques, courants ioniques et patch clamp, 2001.

M. Joffre, Propriétés, structure moléculaire et rôles physiologiques des canaux ionique, 2001.

B. Hille, Ion channels of excitable membranes, 2001.

A. Giuliani, P. Lo-giudice, A. M. Mancini, G. Quatrini, L. Pacifici et al., A Markovian formalization of heart rate dynamics evinces a quantum-like hypothesis, Biological Cybernetics, vol.7, issue.2, pp.181-188, 1996.
DOI : 10.1007/978-3-642-76877-4_11

W. Einthoven, Weiteres ??ber das Elektrokardiogramm, Pfl??ger, Archiv f??r die Gesammte Physiologie des Menschen und der Thiere, vol.122, issue.12, pp.517-548, 1908.
DOI : 10.1007/BF01677829

W. Einthoven, G. Fahr, and A. Waart, ??ber die Richtung und die manifeste Gr??sse der Potentialschwankungen im menschlichen Herzen und ??ber den Einfluss der Herzlage auf die Form des Elektrokardiogramms, Pfl??ger's Archiv f??r die gesamte Physiologie des Menschen und der Tiere, vol.150, issue.6-8, pp.275-315, 1913.
DOI : 10.1007/BF01697566

F. De-coulon and M. Jufer, Introduction à l'électrotechnique, Presse polytechnique et universitaires romandes, 1995.

E. Goldberger, The aVl, aVr, and aVf leads, American Heart Journal, vol.24, issue.3, pp.378-396, 1942.
DOI : 10.1016/S0002-8703(42)90821-4

F. N. Wilson, F. D. Johnston, A. G. Macleod, and P. S. Baker, Electrocardiograms that represent the potential variations of a single electrode, American Heart Journal, vol.9, issue.4, 1934.
DOI : 10.1016/S0002-8703(34)90093-4

F. N. Wilson, F. D. Johnston, F. F. Rosenbaum, H. Erlanger, C. E. Kossmann et al., The precordial electrocardiogram, American Heart Journal, vol.27, issue.1, 1944.
DOI : 10.1016/S0002-8703(44)90603-4

E. Frank, An Accurate, Clinically Practical System For Spatial Vectorcardiography, Circulation, vol.13, issue.5, pp.737-749, 1956.
DOI : 10.1161/01.CIR.13.5.737

J. E. Burnes, B. Taccardi, and Y. Rudy, A Noninvasive Imaging Modality for Cardiac Arrhythmias, Circulation, vol.102, issue.17, pp.2152-2160, 2000.
DOI : 10.1161/01.CIR.102.17.2152

R. N. Ghanem, P. Jia, C. Ramanathan, K. Ryu, A. Markowitz et al., Noninvasive Electrocardiographic Imaging (ECGI): Comparison to intraoperative mapping in patients, Heart Rhythm, vol.2, issue.4, pp.339-54, 2005.
DOI : 10.1016/j.hrthm.2004.12.022

R. N. Ghanem, C. Ramanathan, P. Jia, and Y. Rudy, Heart-surface reconstruction and ecg electrodes localization using fluoroscopy, epipolar geometry and stereovision: application to noninvasive imaging of cardiac electrical activity, IEEE Transactions on Medical Imaging, vol.22, issue.10, pp.1307-1325, 2003.
DOI : 10.1109/TMI.2003.818263

H. S. Oster, B. Taccardi, R. L. Lux, P. R. Ershler, and Y. Rudy, Electrocardiographic Imaging : Noninvasive Characterization of Intramural Myocardial Activation From Inverse-Reconstructed Epicardial Potentials and Electrograms, Circulation, vol.97, issue.15, pp.1496-507, 1998.
DOI : 10.1161/01.CIR.97.15.1496

H. S. Oster, B. Taccardi, R. L. Lux, P. R. Ershler, and Y. Rudy, Noninvasive Electrocardiographic Imaging : Reconstruction of Epicardial Potentials, Electrograms, and Isochrones and Localization of Single and Multiple Electrocardiac Events, Circulation, vol.96, issue.3, pp.1012-1036, 1997.
DOI : 10.1161/01.CIR.96.3.1012

C. Ramanathan, R. N. Ghanem, P. Jia, K. Ryu, and Y. Rudy, Noninvasive electrocardiographic imaging for cardiac electrophysiology and arrhythmia, Nature Medicine, vol.81, issue.4, pp.422-430, 2004.
DOI : 10.1161/01.CIR.81.1.281

C. Ramanathan, P. Jia, R. Ghanem, D. Calvetti, and Y. Rudy, Noninvasive Electrocardiographic Imaging (ECGI): Application of the Generalized Minimal Residual (GMRes) Method, Annals of Biomedical Engineering, vol.31, issue.8, pp.981-94, 2003.
DOI : 10.1114/1.1588655

C. Ramanathan and Y. Rudy, Electrocardiographic Imaging: II. Effect of Torso Inhomogeneities on Noninvasive Reconstruction of Epicardial Potentials, Electrograms, and Isochrones, Journal of Cardiovascular Electrophysiology, vol.12, issue.2, pp.241-52, 2001.
DOI : 10.1046/j.1540-8167.2001.00241.x

J. R. Keltner, M. S. Roos, P. R. Brakeman, and T. F. Budinger, Magnetohydrodynamics of blood flow, Magnetic Resonance in Medicine, vol.1, issue.1, pp.139-188, 1990.
DOI : 10.1080/15368378409035972

M. Brand and O. Heid, Induction of electric fields due to gradient switching: A numerical approach, Magnetic Resonance in Medicine, vol.43, issue.4, pp.731-735, 2002.
DOI : 10.1088/0031-9155/43/2/001

F. Gardiol, Electromagnétisme, IIII. Lausanne: Presses polytechniques et universitaires romanes, 1996.

F. E. Carutern, Prolog to Eddy Currents: Theory and Applications, Proceedings of the IEEE, pp.1156-1558, 1992.

E. E. Kriezis, T. D. Tsiboukis, S. M. Panas, and J. A. Tegopoulos, Eddy currents: theory and applications, Proceedings of the IEEE, pp.1559-1589, 1992.
DOI : 10.1109/5.168666

R. Abächerli, Dossier technique, ECG Sensor (Maglife -Type III), Test-Ergebnisse 1", in R&D, 2003.

R. Abächerli, Dossier technique, ECG Sensor (Maglife -Type III), Test-Ergebnisse 2, R&D, 2003.

R. Abächerli, Dossier technique, ECG Sensor (Maglife -Type III), Test-Ergebnisse 3, R&D, 2003.

R. Abächerli, Dossier technique, ECG Sensor (Maglife -Type III), R&D, 2003.

R. Abächerli, Dossier technique, ECG Sensor (Maglife -Type III), Test-Ergebnisse 5, R&D, 2003.

R. Abächerli, Dossier technique, ECG Sensor (Maglife -Type III), R&D, 2003.

R. Abächerli, Dossier technique, ECG Sensor (Maglife -Type III), R&D, 2003.

H. Stöcker, Taschenbuch mathematischer Formeln und moderner Verfahren". Frankfurt am Main, 1999.

A. V. Oppenheim and R. W. Schafer, Discrete-Time Signal Processing, 1989.

S. W. Smith, The Scientist and Engineer's Guide to Digital Signal Processing". California: California Technical Publishing, 1999.

V. Hombach and H. H. Hiliger, Signal Averaging Technique in Clinical Cardiology, 1981.

Y. W. Lee, Statistical Theory of Communication, 1960.

D. S. Ruckhin, An analysis of average response computations based upon aperiodic stimuli, IEEE Trans Biomed Eng, vol.12, issue.87, 1965.

M. Kunt, Traitement numérique des signaux, Lausanne: Presses polytechniques et universitaires romandes, 1999.

J. F. Taylor, Digital Filter Design Handbook, 1983.

S. M. Kay, Modern Spectrum Estimation, 1988.

S. Haykin, Adaptive Filter Theory, 2002.

B. Widrow and S. D. Stearns, Adaptive Signal Processing, New Jersey, 1985.

G. O. Glentis, K. Berberidis, and S. Theodoridis, Efficient least squares adaptive algorithms for FIR transversal filtering, IEEE Signal Processing Magazine, vol.16, issue.4, p.13, 1999.
DOI : 10.1109/79.774932

D. G. Luenberger, Introduction to Linear and Nonlinear Programming, 1973.

F. Odille, C. Pasquier, R. Abächerli, P. A. Vuissoz, and J. Felblinger, Signal Analyzer and Event Controller (SAEC) for improved patient monitoring and optimum synchronization of MR acquisitions, 2005.

B. Ecri, P. Pike, and . Meeting, USA: AHA Database Testing and reporting performance results of cardiac rhythm and ST-Segment measurement algorithms 138, Medical Instrumentation, vol.158, 0198.

.. Fluide-intracellulaire, 55 flux magnétique, pp.43-82

.. Fréquence-de-larmor and .. Electric, 20 génération des artefacts, gradient, vol.2422, issue.123, p.110

.. Matériel-diamagnétique, 43 matériel paramagnétique, pp.110-111

.. Principe-d-'orthogonalité and .. Processus-de-markov, 83 processus aléatoire29 processus stochastique, 14 réflexion des ondes radiofréquences.............41 réflexions multiples, p.41

T. Restauration-en, 22, 46, 91, 123 restauration par logiciel, p.145