A. L. Copley and G. W. Scott-blair, Comparative observations on adherenoe and consistency of various blood system in living and artificial capillaries, Rheol. Acta, vol.16, pp.170-176, 1961.

R. H. Haynes and A. C. Burton, Role of the non-Newtonian behavior of blood in hemodynamics(114-1494m). in: ~ Pbysiol, pp.943-950, 1949.

C. G. Caro, T. J. Pedley, R. C. Schroter, and W. A. Seed, The mecanics of the circulation Biomecanics-Mecanical properties of living tissues, pp.151-180, 1978.

M. Bessis, Cellules du sang nonnal et patholQgiQue, p.815, 1972.

Y. C. Fung, W. C. Tsang, and P. Patitucci, High-resolution data on the geometry of red blood cells, Biorheology, vol.18, issue.3-6, pp.369-385, 1981.
DOI : 10.3233/BIR-1981-183-606

G. V. Seaman and L. R. Swank, The influence of electrokinetic charge and deformability of the red blood cell on the flow properties of its suspensions1, Biorheology, vol.4, issue.2, p.47, 1967.
DOI : 10.3233/BIR-1967-4203

P. Teitel and G. Galeczki, A simple test for hemorheological investigations: the filtration test. 1. Principles, technique, theory. in: St, Cere. Med. Int (Romania), vol.13, pp.477-488, 1972.

J. F. Stoltz, Main determinants of red blood cell deformability. Clinical and pharmacological applications, Clinical Hemorheology and Microcirculation, vol.2, issue.1-2, p.163, 1982.
DOI : 10.3233/CH-1982-21-221

E. A. Schmalzer, R. Skalak, S. Usami, M. Voyo, and S. Chien, Influence of red cell concentration on filtration of blood cell suspensions, Biorheology, vol.20, issue.1, pp.29-40, 1983.
DOI : 10.3233/BIR-1983-20103

G. A. Marcel, L. George, D. Weill, E. Catry, and Y. Hoffman, Pharmacological Approach to Perfusion, pp.205-222, 1983.
DOI : 10.1007/978-1-4757-0393-1_10

A. L. Copley, Agrégation et désagrégation érythrocytaire. in: Hémorhéologie et agrégation éQ'throcytaire. (Compte rendu du premier symposium international), Genève, E.M. Int. (paris), vol.1, pp.9-21, 1986.

M. H. Knisely, E. H. Bloch, T. S. Eliot, L. Warner, and . Sludged, Sludged Blood, Science, vol.106, issue.2758, p.431, 1947.
DOI : 10.1126/science.106.2758.431

J. F. Stoltz, F. Paulus, and M. Donner, Techniques d'approches de l'agrégation. in: Hémorhéologie et agrégation érythrocytaire, pp.111-121, 1986.

A. Katchalsky, D. Danon, A. Nevo, and A. De-vries, Interaction of basic polyelectrolytes with the red blood cell II. Agglutination of red blood cells by polymeric bases, Biochimica et Biophysica Acta, vol.33, issue.1, pp.120-138, 1959.
DOI : 10.1016/0006-3002(59)90505-0

S. Chien, S. A. Luse, K. M. Jan, S. Usami, L. H. Miller et al., Effects of Macromolecules on the rheology and ultrastructure of red cell suspensions, Proceedings of the 6th Euro.pean Conference on Microcirculation, pp.29-34, 1971.

R. Skalak and S. Chien, Theoretical models of rouleau formation and desaggregation, p.176

M. Donner and P. J. Mills, Stoltz Influence des protéines plasmatiques sur l'agrégation érythrocytaire. in: HémorhéolQgie et agrégatiQn érythrocytaire, pp.3-9, 1988.

J. Charara, Estimation de l'agrégation érythrocytaire par viscosimètre, Thèse de Doctorat Sciences Physiques de l'Université Paris VII. (paris), 1985.

J. F. Stlotz, Perspectives et conclusion. in: Hémorhéologie et agrégation érythrocytaire, pp.210-211, 1988.

D. E. Mcmiilan, J. Strigberger, and N. G. Utterback, Rapidely recovered transient flow resistance-a newly discovered property ofblood. in: Amer, J. PhysiQI, vol.253, pp.919-926, 1987.

H. Schmid-schônbein, J. V. Gosen, L. Heinich, and H. J. Klose, A counter-rotating "rheoscope chamber" for the study of the microrheology of blood cell aggregation by mieroscopie observation and microphotometry, Microvascular Researçh, pp.366-376, 1973.

G. Couarraze and J. L. Grossiord, Initiation à la rhéologie, TEC.& DQÇ, 1983.

A. L. Copley, C. R. Huang, and R. G. King, Rheogoniometric studies of whole human blood at shear rates from 1000 to 0.0009 sec???1, Biorheology, vol.10, issue.1, pp.17-22, 1973.
DOI : 10.3233/BIR-1973-10103

J. C. Healy and M. Joly, Rheological behavior of blood in transient flow12, Biorheology, vol.12, issue.6, pp.335-340, 1975.
DOI : 10.3233/BIR-1975-12602

S. Chien, S. Usami, and R. Skalak, Blood flow in small tube. in: Handbook of Physiology, Circulation. Section on Microcirculation, p.217, 1984.

S. Charm and G. Kurland, Viscometry of Human Blood for Shear Rates of 0-100,000 sec???1, Nature, vol.206, issue.4984, p.1121, 1965.
DOI : 10.1038/206617a0

J. F. Stoltz, S. Gaillard, M. Niclause, and A. Larcan, Mesures de la viscosité sanguine à l'aide d'un viscosimètre rotatif à cylindres coaxiaux, Ann. Biol. Clin, vol.33, p.153, 1975.

S. P. Sutera, V. Seshadri, P. A. Croce, and R. M. Hochmuth, Capillary blood flow, Microvascular Research, vol.2, issue.4, pp.420-433, 1970.
DOI : 10.1016/0026-2862(70)90035-X

J. F. Stoltz, Rappels concernant les paramètres contrôlant les processus fondamentaux en hémorhéologie: importance de l'agrégation érythrocytaire. in: Hémorhéolo&ie et a&ré&ation érythrocytaire. (Compte rendu du premier symposium international), Genève, E.M. Int. (paris), vol.1, pp.22-32, 1986.

H. L. Goldsmith and T. Karino, Physical and Mathematical Models of Blood Flow: Experimental Studies. in: Erythrocyte mechanics and blood flow, pp.165-194, 1980.

T. Fukushima, T. Matsuzawa, and T. Homma, Visualization and finite element analysis of pulsatile flow in models of the abdominal aortic aneurysm, Biorheology, vol.26, issue.2, pp.109-130, 1989.
DOI : 10.3233/BIR-1989-26203

G. B. Thurston, Plasma release-celllayering theory for blood flow [60] Krogh A. The anatomy and physiology of capillaries, pp.199-214, 1922.

A. A. Palmer, Influence of absolute flow rate and rouleaux formation on plasma skimming in vitro, Am. J. Physiol, vol.217, pp.1339-1345, 1969.

J. H. Barbee and G. R. Cokelet, The Farraeus effect in: Microvasc, Res, pp.6-16, 1971.

T. Chan, M. Y. Jaffrin, V. Seshadri, and C. Mc-kay, Flows of red blood cell suspensions through narrow two-dimensional channels, Biorheology, vol.19, issue.1-2, pp.253-267, 1982.
DOI : 10.3233/BIR-1982-191-229

V. Seshadri, C. Mc-kay, and M. Y. Jaffrin, The effect of red blood cell flexibility on blood flow through tubes with diameters in the range 30 to 500 microns, Biorheology, vol.16, issue.6, pp.473-483, 1979.
DOI : 10.3233/BIR-1979-16611

R. Flihraeus and T. Lindqvist, The viscosity of the blood in narrow capillary tubes, Am. J. Physiol, vol.96, pp.562-568, 1931.

S. Blair and G. W. , The importance of sigma phenomenon in the study of blood, Rheol. Acta, vol.123, issue.23, 1958.

R. Skalak and S. Chien, Capillairy flow: history, experiments and theory, pp.311-330, 1981.
DOI : 10.3233/bir-1981-183-602

R. C. Bosworth, LXVI. An interpretation of the sigma phenomenon, The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science, vol.38, issue.283, p.592, 1949.
DOI : 10.1007/BF01502790

R. H. Haynes, Blood Flow through Narrow Tubes, Nature, vol.184, issue.4714, p.679, 1960.
DOI : 10.1038/185679a0

L. Dintenfass, An inversion of the Fahraeus-Linqvist phenomenon in blood flow through capiIIaries of diminishing radius, pp.1099-1100, 1967.

A. L. Copley, G. W. Scott-blair, F. A. Glover, and R. S. Thorley, Capillary flow and wall adherence of bovine blood, plasma and serum in contact with glass and fibrin surfaces, Kolloid-Zeitschrift, vol.26, issue.3, pp.101-107, 1960.
DOI : 10.1007/BF01507418

A. L. Copley and G. W. Scott-blair, Comparative observations on adherence and consistency of various blood systems in living and artificial capillaries. II, Rheologica Acta, vol.8, issue.4-6, pp.665-668, 1961.
DOI : 10.1007/BF01989158

K. Koyama, N. Oki, K. Kanamaru, and E. Wada, Effeet of wall surface on capillary flow, Rep. Prog. Polymer Phys. Japan, pp.95-98, 1970.

S. Oka and . Copley-scott, Blair phenomenon and electric double layer, pp.347-353, 1981.
DOI : 10.3233/bir-1984-21311

J. F. Stoltz and C. Vigneron, Viscosité sanguine et déformabilité des hématies. PIL, 1976.

H. Schmid-schônbein, J. V. Gosen, L. Heinich, and H. J. Klose, A counter-rotating ???rheoscope chamber??? for the study of the microrheology of blood cell aggregation by microscopic observation and microphotometry, Microvascular Research, vol.6, issue.3, pp.366-376, 1973.
DOI : 10.1016/0026-2862(73)90086-1

A. Gaspar-rosas and G. B. Thurston, Erythrocyte aggregate rheology by transmitted and reflected light, Biorheology, vol.25, issue.3, pp.471-487, 1988.
DOI : 10.3233/BIR-1988-25308

P. Haan, M. Gentils, G. Cauchois, and . Erythromètre, in: Techniques en biorheologie, Editions INSERM, vol.143, pp.251-254, 1986.

O. Rhéomètre, Do in: Techniques en biorheologie, Editions INSERM, vol.143, pp.117-119, 1986.

A. L. Copley, Plenary Lecture, Clinical Hemorheology and Microcirculation, vol.5, issue.6, pp.765-812, 1985.
DOI : 10.3233/CH-1985-5602

L. Dintenfass, S. , and S. , Rheology of the packed red blood cells containing haemoglobins A, J. Lab. Clin. Med, vol.643, pp.594-600, 1964.

L. Techniques-de-viscosimètre, le concept de viscosité. in: Techniques en biorheologie, Editions INSERM, vol.143, pp.73-88, 1986.

E. W. Merril, Rheology of blood, Physiol. Rev, vol.494, pp.863-888, 1969.

. Fluofluidimètre, in: Techniques en biorheologie, Editions INSERM, vol.143, pp.349-352, 1986.

P. Ile, E. Zahm, and J. M. , Techniques rhéologiques appliquées à l'étude des mucus. in: Techniques en biorheologie, Editions INSERM, vol.143, pp.89-103, 1986.

J. C. Ravey, Transient rheology in a new type of Couette apparatus., Rheologica Acta, vol.268, issue.1, pp.51-59, 1980.
DOI : 10.1007/BF01523854

H. Schim-sehônbein, Fahraeus-effect-reversal (FER) in compaction stasis (CS): microrheological and haemodynamic consequences of intravascular sedimentation of red cell aggregates, Biorheology, vol.25, issue.1-2, pp.355-366, 1988.
DOI : 10.3233/BIR-1988-251-245

H. Schim-schônbein, Fluid-dynamics and haemorheology in vivo: the interactions of haemodynamic parameters and haemorheological "properties" in determining the flow behaviour of blood in microvascular networks, Boca Raton, 1988.

J. F. Stoltz, S. Gaillard, and M. Guillot, An approach of the viscoelastic properties of blood in transient flow, Biorheology. AICHE Symposium Series, vol.182, issue.4, p.74, 1978.

J. F. Stoltz and M. Lucius, Viscoelasticity and thixotropy of human blood, Biorheology, vol.18, issue.3-6, p.453, 1981.
DOI : 10.3233/BIR-1981-183-611

J. F. Stoltz, Blood rheology: etiology of hyperviscosity syndromes, Inter. Angio, vol.3, p.13, 1984.

P. Teitel, Basic principles of the "filterbility test" (Fr) and analysis of erythrocyte flow behavior, J:ll.QQd ~, vol.3, pp.55-70, 1977.

S. Usami and S. Chien, Optical reflectometry of red blood cell aggregation under shear flow, Proceedings of the 7th EWopean Conference on Microcirculation KARGER, BaseI, pp.91-97, 1972.

Y. C. Fung, Biomechanics: Mechanical pro.perties of living tissues, 1981.

J. F. Stoltz and C. Et-vigneron, viscosité sanguine et déformabilité des hématies. P.I.L Ed, pp.11-23, 1976.

H. Chmiel and E. Et-walitza, On the rheology ofblood and synovial fluids. Research studies press, 1980.

J. F. Stoltz, M. Donner, and E. Puchelle, Téchniques en biorhéologie, Séminaire INSERM, pp.167-182, 1986.

R. L. Whitemore, Rheology of the circulation, 1968.

S. E. Charm and G. S. Et-kurland, Blood flow and microcirculation. Viley, 1974.

D. Quémada and R. Et-droz, Blood viscoelasticity and thixotropy from stress formation and relaxation measurements: A unified model, Biorheology, vol.20, issue.5, pp.635-654, 1983.
DOI : 10.3233/BIR-1983-20520

M. Lucius, M. Lebouché, J. C. Ravey, and J. F. Et-stoltz, Les techniques de viscosimétrie, Techniques avancées en hémorhéologie. D.P.I.C. et LN.P.L. Nancy, pp.405-434, 1983.

M. Lucius, J. C. Ravey, R. Raihani, D. Bernardin, G. Maurice et al., Comportement du sang en régime lentement variable. Tests de lois rhéologiques. in: Résumés Congrès EUROMECH 186, 1984.

J. Wilde, Optimum seeking methods, 1964.

J. C. Ravey, Y. Séré, and J. F. Et-stoltz, Hémorhéologie transitoire appliquée aux propriétés non newtoniennes du sang: utilisation d'un nouveau type de viscosimètre à coussin d'air, C. R. Açad. Sc, vol.292, pp.639-642, 1981.

G. Duvaut and J. L. , Lions Les inéquations en Mécanique: chapitre 6 -fluide rigide viscoplastique de Bingham -Dunod Paris, 1972.

. Dans-un-Écoulement-de-poiseuille, le profil des vitesses se modifie considérablement suivant les paramètres du modèle. En particulier, le débit est très sensibles aux paramètres de la relation proposée

N. Casson, A flow equation for pigment-oil suspensions of the printing-ink type. in: Rheology of disperse ~, pp.84-104, 1959.

J. F. Stoltz, Larcan An investigation of the flow rate curves of a Casson fluid. Application to blood, p.574, 1969.

S. E. Charm-;-g, Kurland Blood flow and microcirculation, 1974.

D. Quémada-;-r, G. Droz, and ;. F. Maurice, Blood viscoelasticity and thixotropy from stress formation and relaxation measurements: A unified model, Stoltz Etude comparative de modèles rhéologiques applicables au sang: Influence des paramètres ct approximation du taux de cisaillement dans un viscosimètre. in: Innovation et Technologie en Biologie et Médecine, pp.635-654, 1962.
DOI : 10.3233/BIR-1983-20520

M. Donner, P. Miiis, and ;. J. , Stoltz Influence des protéines plasmatiques sur l'agrégation érythrocytaire. in: Hémorhéologie et agrégation érythrocytaire, E.M. Int. (paris), vol.2, pp.3-9, 1988.

X. Wang, G. Maurice, ;. Schooneman, and ;. J. , Stoltz Utilisation de la méthode d'analyse en composantes principales pour l'étude des paramètres rhéologiques du sang(Etude préliminaire)

]. X. Référence1, G. Wang, and ;. F. Maurice, Stoltz Etude comparative de modèles rhéologiques applicables au sang: Influence des paramètres et approximation du taux de cisaillement dans un viscosimètre. in: I.T, pp.367-382, 1989.

X. Wang and ;. , Lucius Construction et exploitation d'une banque de données en hémorhéologie. in: Actes du 8e Congrès Français de Mécanique, Nantes, vol.5, pp.332-333, 1987.

M. Donner, P. Mills, and ;. F. , Stoltz Influence des protéines plasmatiques sur l'agrégation érythrocytaire. in: Hémorhéologie et agrégation érythrocytaire, E.M. Int, vol.28, pp.3-9, 1988.

X. Wang, ;. Kouitat, and ;. F. , Soltz Evaluation d'un modèle théorique a deux paramètres applicable aux propriétés rhéologiques du sang

M. R. Mackenzie, H. H. Fudenberg, R. O-'reilly, K. J. Bloch, and D. G. Maki, The hyperviscosity syndrome, Journal of Clinical Investigation, vol.49, issue.1, pp.15-28, 1970.
DOI : 10.1172/JCI106213

J. V. Wells, C. Ries, and H. H. Fudenberg, Hyperviscosity syndrome in multiple myeloma, Abstracts of the XV Congress of the International Society of Haematology, p.348, 1974.

D. J. Wright and D. E. Jenkins, Simplified method for estimation of serum and plasma viscosity in multiple myeloma and related disorders, pp.516-522, 1970.

J. L. Fahey, Serum protein disorders causing clinical symptoms in malignant neoplastic disease, Journal of Chronic Diseases, vol.16, issue.7
DOI : 10.1016/0021-9681(63)90006-7

F. Schooneman, S. Gaillard, F. Paulus, and J. F. Stoltz, Variations h??morh??ologiques au cours de 50 dysglobulin??mies monoclonales trait??es par ??changes plasmatiques, La Revue de M??decine Interne, vol.6, issue.5, pp.487-494, 1985.
DOI : 10.1016/S0248-8663(85)80030-8

N. A. Buskard, D. A. Galton, and J. M. Goldman, Plasma exchange in the long term management of Waldenstrôm's macroglobulinemia, Çgn. Med. Assoc. J, vol.117, pp.135-137, 1977.

F. Skovborg, A. V. Nielsen, J. Schlichtkrull, and J. Ditzef, Blood-viscosity in diabetic patients, p.129, 1966.

E. Davis, B. I. Chazan, J. Landau, and M. Ivry, Clinically Significant Intravascular Red Cell Aggregation, Angiology, vol.6, issue.8, pp.430-434, 1963.
DOI : 10.1177/000331976001100303

L. Dintenfass, Haemorheology of diabetes mellitus, Adv. Microcirc, vol.8, pp.14-36, 1979.