D. Abujudom, P. Thoma, and S. Fariabi, The Effect of Cold Work and Heat Treatment on the Phase Transformations of Near Equiatomic NiTi Shape Memory Alloy, Materials Science Forum, vol.56, issue.58, pp.56-58565, 1990.
DOI : 10.4028/www.scientific.net/MSF.56-58.565

G. Airoldi, G. Riva, M. Vanelli, V. Filippi, and G. Garattini, Oral environment temperature changes induced by cold/hot liquid intake, American Journal of Orthodontics and Dentofacial Orthopedics, vol.112, issue.1, pp.58-63, 1997.
DOI : 10.1016/S0889-5406(97)70274-9

G. Andreasen, Method and system for orthodontic moving teeth, 1977.

G. Andreasen and P. Brady, A use hypothesis for 55 nitinol wire for orthodontics, Angle Orthod, vol.42, pp.172-177, 1972.

G. Andreasen and T. Hilleman, An Evaluation of 55 Cobalt Substituted Nitinol Wire for Use in Orthodontics, The Journal of the American Dental Association, vol.82, issue.6, pp.1373-1375, 1971.
DOI : 10.14219/jada.archive.1971.0209

G. Andreasen, H. Heilmann, and D. Krell, Stiffness changes in thermodynamic nitinol with increasing temperature, Angle Orthod, vol.55, pp.120-126, 1985.

G. Andreasen, L. Montanago, and D. Krell, An investigation of linear dimensional changes as a function of temperature in an 0.010 inch 55cobalt-substituted annealed nitinol alloy wire, American Journal of Orthodontics, vol.82, issue.6, pp.469-472, 1982.
DOI : 10.1016/0002-9416(82)90314-1

G. Andreasen and R. Morrow, Laboratory and clinical analyses of nitinol wire, American Journal of Orthodontics, vol.73, issue.2, pp.142-151, 1978.
DOI : 10.1016/0002-9416(78)90184-7

G. Andreasen, K. Wass, and K. Chan, A review of super-elastic and thermodynamic nitinol wire, Quintessence Int, vol.9, pp.623-626, 1985.

L. Andrews, The straight-wire appliance, origin, controversy, commentary, J Clin Orthod, vol.10, pp.99-114, 1976.

E. Angle, The latest and best in orthodontic mecanisms, Dent Cosmos, vol.70, pp.1143-1158, 1928.

T. Bartzela, C. Senn, and A. Wichelhaus, Load-Deflection Characteristics of Superelastic Nickel-Titanium Wires, The Angle Orthodontist, vol.77, issue.6, pp.991-998, 2007.
DOI : 10.2319/101206-423.1

O. Barwart, J. Rollinger, and A. Burger, An evaluation of the transition temperature range of super-elastic orthodontic NiTi springs using differential scanning calorimetry, The European Journal of Orthodontics, vol.21, issue.5, pp.497-502, 1999.
DOI : 10.1093/ejo/21.5.497

M. Biermann, W. Berzins, and T. Bradley, Thermal Analysis of As-received and Clinically Retrieved Copper-nickel-titanium Orthodontic Archwires, The Angle Orthodontist, vol.77, issue.3, pp.499-503, 2007.
DOI : 10.2319/0003-3219(2007)077[0499:TAOAAC]2.0.CO;2

C. Bourauel, T. Fries, D. Drescher, and R. Plietsch, Surface roughness of orthodontic wires via atomic force microscopy, laser specular reflectance, and profilometry

T. Bradley, W. Brantley, and B. Culbertson, Differential scanning calorimetry (DSC) analyses of superelastic and nonsuperelastic nickel-titanium orthodontic wires, American Journal of Orthodontics and Dentofacial Orthopedics, vol.109, issue.6, pp.589-597, 1996.
DOI : 10.1016/S0889-5406(96)70070-7

T. Bradley, J. Mitchell, and W. Brantley, Surface composition and microtopography of Nickel-Titanium orthodontic wires, J Dent Res, vol.75, p.61, 1996.

W. Brantley, Orthodontic wires Orthodontic materials . Scientific and clinical aspects, pp.77-103, 2001.

W. Brantley, T. Eliades, and A. Litsky, 2 Mechanics and Mechanical Testing of Orthodontic Materials, Orthodontic materials . Scientific and clinical aspects, pp.27-47, 2001.
DOI : 10.1055/b-0034-43090

W. Brantley, M. Iijima, and T. Grentzer, Temperature-modulated DSC study of phase transformations in nickel???titanium orthodontic wires, Thermochimica Acta, vol.392, issue.393, pp.392-393329, 2002.
DOI : 10.1016/S0040-6031(02)00119-3

W. Brantley, M. Iijima, and T. Grentzer, Temperature-modulated DSC provides new insight about nickel-titanium wire transformations, American Journal of Orthodontics and Dentofacial Orthopedics, vol.124, issue.4, pp.387-394, 2003.
DOI : 10.1016/S0889-5406(03)00570-5

W. Brantley, C. Webb, U. Soto, Z. Cai, and B. Mccoy, X-ray diffraction analyses of Copper NiTi orthodontic wires, J Dent Res, vol.76, pp.401-3097, 1997.

W. Brantley, C. Webb, U. Soto, Q. Wu, and A. Cassinelli, X-ray diffraction and Vickers hardness of titanium-containing orthodontic wires, J Dent Res, vol.77, pp.108-132, 1998.

K. Brim and B. Chandler, Changes in oral temperature, Am J Nurs, vol.48, pp.772-773, 1948.

W. Buehler, Proceedings of seventh Navy Science Symposium ONR-16 Office of Technical Services, pp.1-30, 1963.

W. Buehler and W. Cross, 55-Nitinol unique wire alloy with a memory, Wire J, vol.2, pp.41-49, 1969.

W. Buehler, J. Gilfrich, and R. Wiley, Effect of Low???Temperature Phase Changes on the Mechanical Properties of Alloys near Composition TiNi, Journal of Applied Physics, vol.221, issue.5, pp.1475-1477, 1963.
DOI : 10.1063/1.1729603

W. Buehler and F. Wang, A summary of recent research on the nitinol alloys and their potential application in ocean engineering, Ocean Engineering, vol.1, issue.1, pp.105-120, 1968.
DOI : 10.1016/0029-8018(68)90019-X

M. Buonocore, A Simple Method of Increasing the Adhesion of Acrylic Filling Materials to Enamel Surfaces, Journal of Dental Research, vol.44, issue.6, pp.849-853, 1955.
DOI : 10.1177/00220345550340060801

C. Burstone, Modern edgewise mechanics and the segmented arch technique

C. Burstone and A. Goldberg, Beta titanium: A new orthodontic alloy, American Journal of Orthodontics, vol.77, issue.2, pp.121-132, 1980.
DOI : 10.1016/0002-9416(80)90001-9

C. Burstone and A. Goldberg, Orthodontic appliance of titanium alloy, 1980.

C. Burstone and A. Goldberg, Maximum forces and deflections from orthodontic appliances, American Journal of Orthodontics, vol.84, issue.2, pp.95-103, 1983.
DOI : 10.1016/0002-9416(83)90173-2

C. Burstone, B. Qin, and J. Morton, Chinese NiTi wire???A new orthodontic alloy, American Journal of Orthodontics, vol.87, issue.6, pp.445-452, 1985.
DOI : 10.1016/0002-9416(85)90083-1

M. Casa, R. Faltin, K. Faltin, F. Sander, and V. Arana-chavez, Root Resorptions in Upper First Premolars after Application of Continuous Torque Moment Intra-Individual Study, Journal of Orofacial Orthopedics / Fortschritte der Kieferorthop??die, vol.62, issue.4, pp.285-295, 2001.
DOI : 10.1007/PL00001936

A. Cash, S. Good, R. Curtis, and F. Mcdonald, An evaluation of slot size on orthodontic brackets -Are standards as expected ?, Angle Orthod, vol.74, pp.450-543, 2004.

B. Chen, Y. Zhi, and M. Arvystas, Advanced Chinese NiTi alloy wire and clinical observations, Angle Orthod, vol.62, pp.59-66, 1992.

N. Cobb, K. Kula, C. Phillips, and W. Profitt, Efficiency of multi-strand steel, superelastic Ni-Ti and ion-implanted Ni-Ti archwires for initial alignment, Clinical Orthodontics and Research, vol.1, issue.1, pp.12-19, 1998.
DOI : 10.1111/ocr.1998.1.1.12

B. Coluzzi, A. Biscarini, D. Masso, L. Mazzoliai, F. Staffolani et al., Phase transition features of NiTi orthodontic wires subjected to constant bending strains, Journal of Alloys and Compounds, vol.233, issue.1-2, pp.197-205, 1996.
DOI : 10.1016/0925-8388(95)01975-8

M. Cuinet, J. Guivarch, A. Huet, and L. Morgon, Les fils orthodontiques au début du troisième millénaire. Innovation ou amelioration, Orthod Fr, vol.72, pp.221-291, 2001.

G. Dahlberg, Statistical methods for medical and biological students, 1940.

L. Deblock and M. Lucht, Contribution au choix du fil orthodontique, Orthod Fr, vol.57, pp.809-822, 1986.

D. Coster and L. , The use of rustless steel in dentofacial orthopedics, International Journal of Orthodontia, Oral Surgery and Radiography, vol.18, issue.11, pp.1191-1195, 1932.
DOI : 10.1016/S0099-6963(32)90004-0

S. Drake, D. Wayne, J. Powers, and K. Asgar, Mechanical properties of orthodontic wires in tension, bending, and torsion, American Journal of Orthodontics, vol.82, issue.3, pp.206-210, 1982.
DOI : 10.1016/0002-9416(82)90140-3

T. Eliades and A. Athanasiou, In vivo aging of orthodontic alloys: implications for corrosion potential, nickel release, and biocompatibility, Angle Orthod, vol.72, pp.222-237, 2002.

T. Eliades, G. Eliades, A. Athanasiou, and T. Bradley, Surface characterization of retrieved NiTi orthodontic archwires, The European Journal of Orthodontics, vol.22, issue.3, pp.317-326, 2000.
DOI : 10.1093/ejo/22.3.317

T. Eliades, S. Zinelis, M. Papadopoulos, G. Eliades, and A. Athanasiou, Nickel content of as-received and retrieved NiTi and stainless steel arch wires : assessing the nickel release hypothesis, Angle Orthod, vol.74, pp.151-154, 2004.

T. Evans, M. Jones, and R. Newcombe, Clinical comparison and performance perspective of three aligning arch wires, American Journal of Orthodontics and Dentofacial Orthopedics, vol.114, issue.1, pp.32-39, 1998.
DOI : 10.1016/S0889-5406(98)70234-3

J. Feldner, N. Sarkar, J. Sheridan, and D. Lancaster, In vitro torque-deformation characteristics of orthodontic polycarbonate brackets, American Journal of Orthodontics and Dentofacial Orthopedics, vol.106, issue.3, pp.265-272, 1994.
DOI : 10.1016/S0889-5406(94)70046-X

M. Filleul, Banc d'essai permettant de soumettre les arcs orthodontiques à une torsion sur chant

M. Filleul, Comparaison des couples de rappel restitués par le Nitinol, le NiTi Ormco et le Tru-chrome lorqu'ils sont soumis à une torsion sur chant de 20°, 25°, 30° et 35° à une température de 37° Celsius, Orthod Fr, vol.60, pp.851-60, 1989.

M. Filleul and G. Bourgoin, Comparaison de la rigidit?? en torsion des fils couramment utilis??s en orthodontie, Revue d'Orthop??die Dento-Faciale, vol.18, issue.1, pp.67-75, 1984.
DOI : 10.1051/odf/1984005

M. Filleul and G. Bourgoin, Comparaison de la raideur en torsion des fils couramment utilis??s en orthodontie, Revue d'Orthop??die Dento-Faciale, vol.19, issue.4, pp.537-546, 1985.
DOI : 10.1051/odf/1985035

M. Filleul and S. Constant, Torsional properties of Ni???Ti orthodontic archwires, Materials Science and Engineering: A, vol.273, issue.275, pp.273-275775, 1999.
DOI : 10.1016/S0921-5093(99)00414-1

M. Filleul and L. Jordan, Torsional properties of Ni-Ti and Copper Ni-Ti wires: the effect of temperature on physical properties, The European Journal of Orthodontics, vol.19, issue.6, pp.637-646, 1997.
DOI : 10.1093/ejo/19.6.637

M. Filleul, R. Portier, and L. Jordan, Effect of Temperature on Torsional Properties of Ni-Ti and Copper Ni-Ti Orthodontic Wires, Le Journal de Physique IV, vol.07, issue.C5, pp.661-665, 1997.
DOI : 10.1051/jp4:19975105

URL : https://hal.archives-ouvertes.fr/jpa-00255605

G. Fillmore and J. Tomlinson, Heat-treatment of cobalt-chromium alloy, Angle Orthod, vol.46, pp.187-195, 1976.

H. Fischer-brandies, M. Es-souni, N. Koch, K. Raetzke, and O. Bock, Transformation Behavior, Chemical Composition, Surface Topography and Bending Properties of Five Selected 0.016'' ?? 0.022'' NiTi Archwires, Journal of Orofacial Orthopedics/Fortschritte der Kieferorthop???die, vol.64, issue.2, pp.88-99, 2003.
DOI : 10.1007/s00056-003-0062-8

M. Fletcher, S. Miyake, W. Brantley, and B. Culberston, DSC and bending studies of a new shape-memory orthodontic wire, J Dent Res, vol.71, pp.169-505, 1992.

P. Garrec, B. Tavernier, and L. Jordan, Evolution of flexural rigidity according to the cross-sectional dimension of a superelastic nickel titanium orthodontic wire, European Journal of Orthodontics, vol.27, issue.4, pp.402-407, 2005.
DOI : 10.1093/ejo/cji014

J. Ghanbaya and Y. Ravaux, Microscopie électronique à balayage, cours, UHP, 2007.

F. Gill and J. Planell, Effect of copper addition on the superelastic behavior of Ni-Ti shape memory alloys for orthodontic applications, Journal of Biomedical Materials Research, vol.36, issue.5, pp.682-688, 1999.
DOI : 10.1016/0002-9416(80)90303-6

J. Goldberg and C. Burstone, An Evaluation of Beta Titanium Alloys for Use in Orthodontic Appliances, Journal of Dental Research, vol.31, issue.2, pp.593-599, 1979.
DOI : 10.1002/jctb.5020251205

A. Goldberg and C. Burstone, Advanced thermoplastics for orthodontics. US patent # 7 186 115, 6 Mars, 2007.

T. Goryczka and H. Morawiec, Structure studies of the R-phase using X-ray diffraction methods, Journal of Alloys and Compounds, vol.367, issue.1-2, pp.137-141, 2004.
DOI : 10.1016/j.jallcom.2003.08.025

M. Grimsdottir and A. Hensten-pettersen, Surface analysis of nickel-titanium archwire used in vivo, Dental Materials, vol.13, issue.3, pp.163-167, 1997.
DOI : 10.1016/S0109-5641(97)80118-2

J. Gurgel, S. Kerr, J. Powers, and V. Lecrone, Force-deflection properties of superelastic nickel-titanium archwires, American Journal of Orthodontics and Dentofacial Orthopedics, vol.120, issue.4, pp.378-382, 2001.
DOI : 10.1067/mod.2001.117200

J. Gurgel, S. Stephen, J. Powers, and A. Pinzan, Torsional properties of commercial nickel-titanium wires during activation and deactivation, American Journal of Orthodontics and Dentofacial Orthopedics, vol.120, issue.1, pp.76-79, 2001.
DOI : 10.1067/mod.2001.115147

H. Hamanaka, K. Watanabe, and I. Miura, New ultra-elastic NiTi orthodontic wire, DE J Dent Eng, vol.60, pp.28-33, 1982.

A. Hohmann, U. Wolfram, M. Geiger, A. Boryor, C. Sander et al., Periodontal Ligament Hydrostatic Pressure with Areas of Root Resorption after Application of a Continuous Torque Moment, The Angle Orthodontist, vol.77, issue.4, pp.653-659, 2007.
DOI : 10.2319/060806-234

W. Houston, The analysis of errors in orthodontic measurements, American Journal of Orthodontics, vol.83, issue.5, pp.382-390, 1983.
DOI : 10.1016/0002-9416(83)90322-6

M. Jones, H. Staniford, and C. Chan, Comparison of superelastic NiTi and multistranded stainless steel wires in initial alignment, J Clin Orthod, vol.24, pp.611-613, 1990.

S. Kapila, G. Reichhold, R. Anderson, and L. Watanabe, Effects of clinical recycling on mechanical properties of nickel-titanium alloy wires, American Journal of Orthodontics and Dentofacial Orthopedics, vol.100, issue.5, pp.428-435, 1991.
DOI : 10.1016/0889-5406(91)70082-8

S. Kapila and R. Sachdeva, Mechanical properties and clinical applications of orthodontic wires, American Journal of Orthodontics and Dentofacial Orthopedics, vol.96, issue.2, pp.100-109, 1989.
DOI : 10.1016/0889-5406(89)90251-5

S. Kapila, J. Haugen, and L. Watanabe, Load-deflection characteristics of nickel-titanium alloy wires after clinical recycling and dry heat sterilization, American Journal of Orthodontics and Dentofacial Orthopedics, vol.102, issue.2, pp.120-126, 1992.
DOI : 10.1016/0889-5406(92)70023-4

S. Khier, Structural characterization, biomechanical properties, and potentiodynamic polarization behaviour of nickel-titanium orthodontic wire alloys, 1988.

S. Khier, W. Brantley, and R. Fournelle, Bending properties of superelastic and nonsuperelastic nickel-titanium orthodontic wires, American Journal of Orthodontics and Dentofacial Orthopedics, vol.99, issue.4, pp.310-318, 1991.
DOI : 10.1016/0889-5406(91)70013-M

R. Kusy and J. Whitley, Assessment of second-order clearances between orthodontic archwires and bracket slots via the critical contact angle for binding, Angle Orthod, vol.69, pp.71-80, 1999.

M. Iijima, K. Endo, H. Ohno, Y. Yonekura, and I. Mizoguchi, Corrosion Behavior and Surface Structure of Orthodontic Ni-Ti Alloy Wires., Dental Materials Journal, vol.20, issue.1, pp.103-113, 2001.
DOI : 10.4012/dmj.20.103

M. Iijima, H. Ohno, I. Kawashima, K. Endo, W. Brantley et al., Micro X-ray diffraction study of superelastic nickel???titanium orthodontic wires at different temperatures and stresses, Biomaterials, vol.23, issue.8, pp.1769-1774, 2002.
DOI : 10.1016/S0142-9612(01)00303-9

M. Iijima, H. Ohno, I. Kawashima, K. Endo, and I. Mizoguchi, Mechanical behavior at different temperatures and stresses for superelastic nickel??????titanium orthodontic wires having different transformation temperatures, Dental Materials, vol.18, issue.1, pp.88-93, 2002.
DOI : 10.1016/S0109-5641(01)00025-2

L. Jordan, M. Chandrasekaran, M. Masse, and G. Bouquet, Study of the phase transformations in NiTi based shape memory alloys, J Phys IV France, vol.5, issue.2, pp.489-494, 1995.
URL : https://hal.archives-ouvertes.fr/jpa-00253661

L. Jordan, M. Filleul, and R. Portier, Les arcs orthodontiques ?? m??moire de forme : structures et propri??t??s, Revue d'Orthop??die Dento-Faciale, vol.31, issue.2, pp.199-211, 1997.
DOI : 10.1051/odf/1997018

S. Khier, W. Brantley, R. Fournelle, and T. Ehlert, XRD and DSC studies of NiTi orthodontic wire alloys, J Dent Res, vol.68, p.386, 1989.

L. Jordan, M. Masse, J. Collier, and G. Bouquet, Etude comparative des ??volutions structurales intervenant dans des alliages ?? m??moire de forme du type NiTi et Ni-Ti-Co, Le Journal de Physique IV, vol.04, issue.C3, pp.157-162, 1994.
DOI : 10.1051/jp4:1994322

L. Leu, R. Fournelle, W. Brantley, and T. Ehlert, Evidence of R structure in superelastic NiTi orthodontic wires, J Dent Res, vol.69, p.313, 1990.

C. Longman and G. Pearson, Variations in tooth, surface temperature in the oral cavity during fluid intake, Biomaterials, vol.8, issue.5, pp.411-414, 1987.
DOI : 10.1016/0142-9612(87)90016-0

I. Lopez, J. Goldberg, and C. Burstone, Bending characteristics of nitinol wire, American Journal of Orthodontics, vol.75, issue.5, pp.569-575, 1979.
DOI : 10.1016/0002-9416(79)90075-7

A. Goldberg, C. Burstone, and H. Koenig, Material Science Plastic Deformation of Orthodontic Wires, Journal of Dental Research, vol.95, issue.9, pp.1016-1020, 1983.
DOI : 10.1016/0002-9416(79)90075-7

B. Mccoy, Comparison of compositions and differential scanning calorimetric analyses of the new copper-nickel-titanium orthodontic wires [MS thesis], 1996.

B. Mccoy, W. Brantley, B. Culberston, and J. Mitchell, DSC and EDS analyses of new Copper NiTi orthodontic wires, J Dent Res, vol.76, p.400, 1997.

T. Meling and J. Ødegaard, The effect of cross-sectional dimensional variations of square and rectangular chrome-cobalt archwires in torsion, Angle Orthod, vol.68, pp.239-248, 1998.

T. Meling and J. Ødegaard, The effect of temperature on the elastic responses to longitudinal torsion of rectangular nickel titanium archwires, Angle Orthod, vol.68, pp.357-368, 1998.

T. Meling and J. Ødegaard, The effect of short-term temperature changes on the mechanical properties of rectangular nickel titanium archwires tested in torsion, Angle Orthod, vol.68, pp.369-376, 1998.

T. Meling and J. Ødegaard, On the variability of cross-sectional dimensions and torsional properties of rectangular nickel-titanium arch??wires, American Journal of Orthodontics and Dentofacial Orthopedics, vol.113, issue.5, pp.546-557, 1998.
DOI : 10.1016/S0889-5406(98)70266-5

T. Meiling and J. Ødegaard, The effect of second-order couple on the application of torque, American Journal of Orthodontics and Dentofacial Orthopedics, vol.113, issue.3, pp.256-262, 1998.
DOI : 10.1016/S0889-5406(98)70294-X

T. Meiling and J. Ødegaard, The effect of short-term temperature changes on superelastic nickel-titanium archwires activated in orthodontic bending, American Journal of Orthodontics and Dentofacial Orthopedics, vol.119, issue.3, pp.263-273, 2001.
DOI : 10.1067/mod.2001.112451

T. Meling, J. Ødegaard, and E. Meling, A theoretical evaluation of the influence of variation in bracket slot height and wire rounding on the amount of torsional play between bracket and wire, Kieferorthop Mittlg, vol.7, pp.41-48, 1993.

T. Meling, J. Ødegaard, and E. Meling, Cross-sectional stability of square and rectangular stainless steel wires, Kieferorthop Mittlg, vol.8, pp.41-54, 1994.

T. Meling, J. Ødegaard, and E. Meling, On mechanical properties of square and rectangular stainless steel wires tested in torsion, American Journal of Orthodontics and Dentofacial Orthopedics, vol.111, issue.3, pp.310-320, 1997.
DOI : 10.1016/S0889-5406(97)70190-2

T. Meling, J. Ødegaard, and D. Segner, On bracket slot height : a methodologic study, Am J Orthod Dentofacial Orthop, vol.113, pp.387-393, 1998.

G. Michal and R. Sinclair, The structure of TiNi martensite, Acta Crystallographica Section B Structural Crystallography and Crystal Chemistry, vol.37, issue.10, pp.1803-1807, 1981.
DOI : 10.1107/S0567740881007292

F. Miura, M. Mogi, Y. Ohura, and H. Hamanaka, The super-elastic property of the

F. Miura, M. Mogi, Y. Ohura, and M. Karibe, The super-elastic property of the Japanese NiTi alloy wire for use in orthodontics, American Journal of Orthodontics and Dentofacial Orthopedics, vol.90, issue.1
DOI : 10.1016/0889-5406(86)90021-1

F. Miura, M. Mogi, and Y. Ohura, Japanese NiTi alloy wire: use of the direct electric resistance heat treatment method, The European Journal of Orthodontics, vol.10, issue.1, pp.187-191, 1988.
DOI : 10.1093/ejo/10.1.187

S. Miyazaki and K. Otsuka, Deformation and transition behavior associated with theR-phase in Ti-Ni alloys, Metallurgical Transactions A, vol.33, issue.1, pp.53-63, 1986.
DOI : 10.1179/000844365795164891

R. Moore, J. Watts, J. Hood, and D. Burritt, Intra-oral temperature variation over 24 hours, The European Journal of Orthodontics, vol.21, issue.3, pp.249-261, 1999.
DOI : 10.1093/ejo/21.3.249

URL : https://academic.oup.com/ejo/article-pdf/21/3/249/1299965/210249.pdf

W. Mullins, M. Bagby, and T. Norman, Mechanical behavior of thermo-responsive orthodontic archwires, Dental Materials, vol.12, issue.5-6, pp.308-314, 1996.
DOI : 10.1016/S0109-5641(96)80039-X

H. Nakano, K. Satoh, R. Norris, J. T. Kamegai, T. Ishikawa et al., Mechanical properties of several nickel-titanium alloy wires in three-point bending tests, American Journal of Orthodontics and Dentofacial Orthopedics, vol.115, issue.4, pp.390-395, 1999.
DOI : 10.1016/S0889-5406(99)70257-X

R. Nelsen, R. Wolcott, and G. Paffenbarger, Fluid Exchange at the Margins of Dental Restorations, The Journal of the American Dental Association, vol.44, issue.3, pp.288-295, 1952.
DOI : 10.1016/S0002-8177(52)43006-8

R. Nikolai, Response of dentition and periodontium to force Bioengineering analysis of orthodontics mechanics, Philadelphia : Lea & Febiger, pp.146-193, 1985.

J. Ødegaard, T. Meling, E. Meling, and D. Segner, A new instrument to measure torsional moments in orthodontic appliances, Kieferorthop Mittlg, vol.6, pp.53-61, 1993.

J. Ødegaard, E. Meling, and T. Meling, An evaluation of the torsional moments developed in orthodontic applications. An in vitro study, American Journal of Orthodontics and Dentofacial Orthopedics, vol.105, issue.4, pp.392-400, 1994.
DOI : 10.1016/S0889-5406(94)70134-2

J. Ødegaard, T. Meling, and E. Meling, The effects of loops on the torsional stiffnesses of rectangular wires: An in vitro study, American Journal of Orthodontics and Dentofacial Orthopedics, vol.109, issue.5, pp.496-505, 1996.
DOI : 10.1016/S0889-5406(96)70134-8

Y. Ohura, Orthodontic studies on super elastic NiTi wire. 1. Mechanical properties, J Jpn Orthod Soc, vol.43, pp.71-80, 1984.

Y. Ohura, Orthodontic studies on super-elastic NiTi alloy wire. 2. Bending and controlling the amount of force, Nippon Kyosei Shika Gakkai Zasshi, vol.47, pp.92-104, 1988.

J. Oltjen, M. Duncanson, J. Ghosh, R. Nanda, and G. Currier, Stiffness-deflection behaviour of selected orthodontic wires, Angle Orthod, vol.67, pp.209-218, 1997.

Y. Oshida, S. Miyasaki, and R. Sachdeva, Microanalytical studies of orthodontic archwire, J Dent Res, vol.69, pp.313-1633, 1990.

Y. Oshida, R. Sachdeva, and S. Miyazaki, Microanalytical characterization and surface modification of TiNi orthodontic archwires, Biomed Mater Eng, vol.2, pp.51-69, 1992.

F. Parvizi and W. Rock, The load/deflection characteristics of thermally activated orthodontic archwires, The European Journal of Orthodontics, vol.25, issue.4, pp.417-421, 2003.
DOI : 10.1093/ejo/25.4.417

E. Popov, Introduction to mechanics of solids, 1968.

W. Profitt, Contemporary orthodontic appliances, Contemporary Orthodontics. 4 th edition, pp.395-430, 2007.

S. Quo, S. Marshall, and G. Marshall, Chemical and phase contents analysis of Ni-Ti wires, J Dent Res, vol.73, p.413, 1994.

K. Reitan, Some factors determining the evaluation of forces in orthodontics, American Journal of Orthodontics, vol.43, issue.1, pp.32-45, 1957.
DOI : 10.1016/0002-9416(57)90114-8

R. L. Sachdeva, orthodontie à température de transition variable . Maintenant une réalité avec le copper NiTi, 1994.

R. Sachdeva and S. Miyazaki, Superelastic NiTialloys in orthodontics Engineering aspects of shape memory alloys

R. Sachdeva, S. Miyazaki, and F. Farzin-nia, Orthodontic archwire and method of moving teeth, 1991.

M. Sakima, M. Dalstra, and B. Melsen, How does temperature influence the properties of rectangular nickel-titanium wires?, The European Journal of Orthodontics, vol.28, issue.3, pp.282-291, 2006.
DOI : 10.1093/ejo/cji079

J. Sebanc, W. Brantley, J. Pincsak, and J. Conover, Variability of effective root torque as a function of edge bevel on orthodontic arch wires, American Journal of Orthodontics, vol.86, issue.1, pp.43-50, 1984.
DOI : 10.1016/0002-9416(84)90275-6

D. Segner and D. Ibe, Properties of superelastic wires and their relevance to orthodontic treatment, The European Journal of Orthodontics, vol.17, issue.5, pp.395-402, 1995.
DOI : 10.1093/ejo/17.5.395

F. Sernetz, Qualität und Normung orthodontischer Produkte aus der Sicht des Herstellers, Kieferorthop Mittlg, vol.7, pp.13-26, 1993.

R. Siatkowsky, Loss of anterior torque control due to variations in bracket slot and archwire dimensions, J Clin Orthod, vol.33, pp.508-510, 1999.

E. Silverman, M. Cohen, A. Gianelly, and V. Dietz, A universal direct bonding system for both metal and plastic brackets, American Journal of Orthodontics, vol.62, issue.3, pp.236-244, 1972.
DOI : 10.1016/S0002-9416(72)90264-3

M. Simon, Technic for construction of one piece stainless steel arches with auxiliary springs (without soldering or welding), International Journal of Orthodontia and Dentistry for Children, vol.21, issue.9, pp.841-846, 1935.
DOI : 10.1016/S0097-0522(35)90369-0

G. Smith, J. Fraunhofer, and G. Casey, The effect of clinical use and sterilization on selected orthodontic arch wires, American Journal of Orthodontics and Dentofacial Orthopedics, vol.102, issue.2, pp.153-159, 1992.
DOI : 10.1016/0889-5406(92)70028-9

T. Thayer, M. Bagby, R. Moore, and R. Deangelis, X-ray diffraction of NiTi orthodontic archwires, J Dent Res, vol.72, p.139, 1993.

T. Thayer, M. Bagby, R. Moore, and R. Deangelis, X-ray diffraction of nitinol orthodontic arch wires, American Journal of Orthodontics and Dentofacial Orthopedics, vol.107, issue.6, pp.604-612, 1995.
DOI : 10.1016/S0889-5406(95)70103-6

T. Todoroki and H. Tamura, Effect of Heat Treatment after Cold Working on the Phase Transformation in TiNi Alloy, Transactions of the Japan Institute of Metals, vol.28, issue.2, pp.83-94, 1987.
DOI : 10.2320/matertrans1960.28.83

R. Tonner and N. Waters, The characteristics of super-elastic Ni-Ti wires in three-point bending. Part l: The effect of temperature, The European Journal of Orthodontics, vol.16, issue.5, pp.409-419, 1994.
DOI : 10.1093/ejo/16.5.409

C. Tweed, Soldering technic for steel arch wire, Angle Orthod, vol.11, pp.68-69, 1941.

A. Verstrynge, V. Humbeeck, and G. Willems, In-vitro evaluation of the material characteristics of stainless steel and beta-titanium orthodontic wires, American Journal of Orthodontics and Dentofacial Orthopedics, vol.130, issue.4, pp.460-470, 2006.
DOI : 10.1016/j.ajodo.2004.12.030

F. Van-loo, G. Bastin, and A. Leenen, Phase relations in the ternary Ti???Niz.sbnd;Cu system at 800 and 870 ??C, Journal of the Less Common Metals, vol.57, issue.1, pp.111-121, 1978.
DOI : 10.1016/0022-5088(78)90167-4

A. Volchansky, C. , and P. , Variations in oral temperature, Journal of Oral Rehabilitation, vol.86, issue.5, pp.605-611, 1994.
DOI : 10.1016/0300-5712(85)90029-6

H. Wagner and C. Jackson, What can you do with that " memory alloy, Materials Eng, p.7028, 1969.

K. Watanabe, Studies on new superelastic NiTi orthodontic wire. (Part 1) Tensile and bend test, Shika Rikogaku Zasshi, vol.23, pp.45-57, 1982.

K. Watanabe and H. Hamanaka, Use of NiTi alloy in dentistry, Kokubyo Gakkai Zasshi, vol.249, p.48, 1981.

A. West, M. Jones, and R. Newcombe, Multiflex versus superelastic: A randomized clinical trial of the tooth alignment ability of initial arch wires, American Journal of Orthodontics and Dentofacial Orthopedics, vol.108, issue.5, pp.464-471, 1995.
DOI : 10.1016/S0889-5406(95)70046-3

J. Wilkinson, Some metallurgical aspects of orthodontic stainless steel, American Journal of Orthodontics, vol.48, issue.3, pp.192-206, 1962.
DOI : 10.1016/0002-9416(62)90202-6

P. Wilkinson, P. Dysart, J. Hood, and G. Herbison, Load-deflection characteristics of superelastic nickel-titanium orthodontic wires, American Journal of Orthodontics and Dentofacial Orthopedics, vol.121, issue.5, pp.483-495, 2002.
DOI : 10.1067/mod.2002.121819

T. Yoneyama, H. Doi, and H. Hamanaka, Bending properties and transformation temperatures of heat treated Ni-Ti alloy wire for orthodontic appliances, Journal of Biomedical Materials Research, vol.11, issue.3, pp.399-402, 1993.
DOI : 10.4012/dmj.11.1

T. Yoneyama, H. Doi, H. Hamanaka, Y. Okamoto, M. Mogi et al., Super-Elasticity and Thermal Behavior of Ni-Ti Alloy Orthodontic Arch Wires, Dental Materials Journal, vol.11, issue.1, pp.1-10, 1992.
DOI : 10.4012/dmj.11.1