D. R. Messroghli, A. Radjenovic, S. Kozerke, D. M. Higgins, M. U. Sivananthan et al., Modified Look-Locker inversion recovery (MOLLI) for high-resolutionT1 mapping of the heart, Magnetic Resonance in Medicine, vol.52, issue.1, pp.141-146, 2004.

K. Chow, J. A. Flewitt, J. D. Green, J. J. Pagano, M. G. Friedrich et al., Saturation recovery single-shot acquisition (SASHA) for myocardial T1 mapping, Magnetic resonance in medicine, vol.71, issue.6, pp.2082-2095, 2014.

H. Arheden, Measurement of the Distribution Volume of Gadopentetate Dimeglumine at Echo-planar MR Imaging to Quantify Myocardial Infarction: Comparison with 99mTc-DTPA Autoradiography in Rats, Radiology, vol.211, issue.3, pp.698-708, 1999.

M. Ugander, Extracellular volume imaging by magnetic resonance imaging provides insights into overt and sub-clinical myocardial pathology, Eur Heart J, vol.33, issue.10, pp.1268-1278, 2012.

M. Salerno and C. M. Kramer, Advances in Parametric Mapping With CMR Imaging, JACC: Cardiovascular Imaging, vol.6, issue.7, pp.806-822, 2013.

A. J. Taylor, M. Salerno, R. Dharmakumar, and M. Jerosch-herold, T1 Mapping, vol.9, pp.67-81, 2016.
URL : https://hal.archives-ouvertes.fr/hal-02931808

M. Nathan, L. C. Ying, C. Pierre, B. David, and L. João, Assessment of Myocardial Fibrosis with Cardiac Magnetic Resonance, J Am Coll Cardiol, vol.57, issue.8, pp.891-903, 2011.

R. J. Everett, C. G. Stirrat, S. I. Semple, D. E. Newby, M. R. Dweck et al., Assessment of myocardial fibrosis with T1 mapping MRI, Clinical Radiology, vol.71, issue.8, pp.768-778, 2016.

E. Micard, D. Husson, C. Team, and J. Felblinger, ArchiMed: A Data Management System for Clinical Research in Imaging, Front. ICT, vol.3, 2016.

I. I. Rabi, J. R. Zacharias, S. Millman, and P. Kusch, A New Method of Measuring Nuclear Magnetic Moment, Physical Review, vol.53, issue.4, pp.318-318, 1938.

J. Keeler, Understanding NMR Spectroscopy, p.210

F. Bloch, Nuclear induction, Physical review, vol.70, issue.7-8, p.460, 1946.

E. M. Purcell, H. C. Torrey, and R. V. Pound, Resonance Absorption by Nuclear Magnetic Moments in a Solid, Physical Review, vol.69, issue.1-2, pp.37-38, 1946.

P. A. Bottomley, C. J. Hardy, R. E. Argersinger, and G. Allen-moore, A review of 1H nuclear magnetic resonance relaxation in pathology: Are T1 and T2 diagnostic?, Medical Physics, vol.14, issue.1, pp.1-37, 1987.

G. J. Stanisz, T1, T2 relaxation and magnetization transfer in tissue at 3T, Magnetic Resonance in Medicine, vol.54, issue.3, pp.507-512, 2005.

J. R. Singer, H. Y. Carr, S. Millman, and F. W. Wehrli, Sharper Images of Mri's Origins, Physics Today, vol.46, issue.1, pp.15-96, 1993.

R. Damadian, Tumor Detection by Nuclear Magnetic Resonance, Science, vol.171, issue.3976, pp.1151-1153, 1971.

R. Damadian, M. Goldsmith, and L. Minkoff, NMR in cancer: XVI. FONAR image of the live human body, Physiol. Chem. Phys, vol.9, issue.1, pp.97-100, 1977.

P. C. Lauterbur, Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance, Nature, vol.242, issue.5394, pp.190-191, 1973.

P. Mansfield and P. K. Grannell, NMR 'diffraction' in solids?, Journal of Physics C: Solid State Physics, vol.6, issue.22, pp.422-426, 1973.

P. Mansfield and A. A. Maudsley, Medical imaging by NMR, The British Journal of Radiology, vol.50, issue.591, pp.188-194, 1977.

E. L. Hahn, Spin Echoes, Phys. Rev, vol.80, issue.4, pp.580-594, 1950.

R. E. Hendrick, T. R. Nelson, and W. R. Hendee, Optimizing tissue contrast in magnetic resonance imaging, Magnetic Resonance Imaging, vol.2, issue.3, pp.90005-90010, 1984.

E. L. Hahn, Detection of sea-water motion by nuclear precession, Journal of Geophysical Research, vol.65, issue.2, pp.776-777, 1960.

A. Abragam, The Principles of Nuclear Magnetism, 1983.

J. Frahm, A. Haase, and D. Matthaei, Rapid NMR imaging of dynamic processes using the FLASII technique, Magnetic Resonance in Medicine, vol.3, issue.2, pp.321-327, 1986.

A. Haase, J. Frahm, D. Matthaei, W. Hanicke, and K. Merboldt, FLASH imaging. Rapid NMR imaging using low flip-angle pulses, Journal of Magnetic Resonance, vol.67, issue.2, pp.90433-90439, 1969.

M. A. Bernstein, K. F. King, and X. J. Zhou, CHAPTER 14 -BASIC PULSE SEQUENCES, Handbook of MRI Pulse Sequences, pp.579-647, 2004.

A. Haase, Snapshot flash mri. applications to t1, t2, and chemical-shift imaging, Magnetic Resonance in Medicine, vol.13, issue.1, pp.77-89, 1990.

R. R. Ernst and W. A. Anderson, Application of Fourier Transform Spectroscopy to Magnetic Resonance, Review of Scientific Instruments, vol.37, issue.1, pp.93-102, 1966.

H. B. Larsson, T. Fritz-hansen, E. Rostrup, L. Søndergaard, P. Ring et al., Myocardial perfusion modeling using MRI, Magnetic Resonance in Medicine, vol.35, issue.5, pp.716-726, 1996.

T. Fritz-hansen, E. Rostrup, P. B. Ring, and H. B. Larsson, Quantification of gadolinium-dtpa concentrations for different inversion times using an ir-turbo flash pulse sequence: a study on optimizing multislice perfusion imaging, Magnetic Resonance Imaging, vol.16, issue.8, pp.103-112, 1998.

M. Jerosch-herold, N. Wilke, A. E. Stillman, and R. F. Wilson, Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolution, Medical Physics, vol.25, issue.1, p.73, 1998.

H. Y. Carr, Steady-State Free Precession in Nuclear Magnetic Resonance, Phys. Rev, vol.112, issue.5, pp.1693-1701, 1958.

G. B. Chavhan, P. S. Babyn, B. G. Jankharia, H. M. Cheng, and M. M. Shroff, Steady-State MR Imaging Sequences: Physics, Classification, and Clinical Applications, vol.28, pp.1147-1160, 2008.

M. Schär, S. Kozerke, S. E. Fischer, and P. Boesiger, Cardiac SSFP imaging at, vol.3

, Magnetic Resonance in Medicine, vol.51, issue.4, pp.799-806, 2004.

J. Lohrke, 25 Years of Contrast-Enhanced MRI: Developments, Current Challenges and Future Perspectives, Adv Ther, vol.33, pp.1-28, 2016.

H. Weinmann, R. Brasch, W. Press, and G. Wesbey, Characteristics of gadolinium-DTPA complex: a potential NMR contrast agent, American Journal of Roentgenology, vol.142, issue.3, pp.619-624, 1984.

M. Laniado, H. J. Weinmann, W. Schörner, R. Felix, and U. Speck, First use of GdDTPA/dimeglumine in man, Physiological chemistry and physics and medical NMR, vol.16, issue.2, pp.157-165, 1984.

D. Carr, Gadolinium-DTPA as a contrast agent in MRI: initial clinical experience in 20 patients, American Journal of Roentgenology, vol.143, issue.2, pp.215-224, 1984.

P. Caravan, J. J. Ellison, T. J. Mcmurry, and R. B. Lauffer, Gadolinium(III) Chelates as MRI Contrast Agents: Structure, Dynamics, and Applications, vol.99, pp.2293-2352, 1999.

L. O. Morgan, A. W. Nolle, ;. Ii, . Cr+++, . Mn++ et al., Proton Spin Relaxation in Aqueous Solutions of Paramagnetic Ions, J. Chem. Phys, vol.31, issue.2, pp.365-368, 1959.

G. Brix, W. Semmler, R. Port, L. R. Schad, G. Layer et al., Pharmacokinetic Parameters in CNS Gd-DTPA Enhanced MR Imaging, Journal of Computer Assisted Tomography, vol.15, issue.4, pp.621-628, 1991.

T. J. Clough, L. Jiang, K. Wong, and N. J. Long, Ligand design strategies to increase stability of gadolinium-based magnetic resonance imaging contrast agents, Nat Commun, vol.10, issue.1, pp.1-14, 2019.

H. J. Weinmann, M. Laniado, and W. Mützel, Pharmacokinetics of GdDTPA/dimeglumine after intravenous injection into healthy volunteers, Physiol Chem Phys Med NMR, vol.16, issue.2, pp.167-172, 1984.

S. Aime and P. Caravan, Biodistribution of gadolinium-based contrast agents, including gadolinium deposition, J Magn Reson Imaging, vol.30, issue.6, pp.1259-1267, 2009.

E. Lancelot, Revisiting the Pharmacokinetic Profiles of Gadolinium-Based Contrast Agents: Differences in Long-Term Biodistribution and Excretion, Investigative Radiology, vol.51, issue.11, pp.691-700, 2016.

L. Pasquini, Gadolinium-Based Contrast Agent-Related Toxicities, CNS Drugs, vol.32, issue.3, pp.229-240, 2018.

J. Ferré, E. Bannier, H. Raoult, G. Mineur, B. Carsin-nicol et al., Arterial spin labeling (ASL) perfusion: Techniques and clinical use, Diagnostic and Interventional Imaging, vol.94, pp.1211-1223, 2013.

E. C. Wong, An introduction to ASL labeling techniques: Introduction to ASL, Journal of Magnetic Resonance Imaging, vol.40, issue.1, pp.1-10, 2014.

F. Kober, T. Jao, T. Troalen, and K. S. Nayak, Myocardial arterial spin labeling, Journal of Cardiovascular Magnetic Resonance, vol.18, issue.1, 2016.
URL : https://hal.archives-ouvertes.fr/hal-01425517

M. Kleppestø, T2*-correction in dynamic contrast-enhanced MRI from double-echo acquisitions, Journal of Magnetic Resonance Imaging, vol.39, issue.5, pp.1314-1319, 2014.

D. T. Ginat, M. W. Fong, D. J. Tuttle, S. K. Hobbs, and R. C. Vyas, Cardiac Imaging: Part 1, MR Pulse Sequences, Imaging Planes, and Basic Anatomy, vol.197, pp.808-815, 2011.

M. A. Griswold, Generalized autocalibrating partially parallel acquisitions (GRAPPA), Magnetic Resonance in Medicine, vol.47, issue.6, pp.1202-1210, 2002.

K. P. Pruessmann, M. Weiger, M. B. Scheidegger, and P. Boesiger, SENSE: Sensitivity encoding for fast MRI, Magnetic Resonance in Medicine, vol.42, issue.5, pp.952-962, 1999.

D. A. Feinberg, J. D. Hale, J. C. Watts, L. Kaufman, and A. Mark, Halving MR imaging time by conjugation: demonstration at 3.5 kG, Radiology, vol.161, issue.2, pp.527-531, 1986.

O. N. Jaspan, R. Fleysher, and M. L. Lipton, Compressed sensing MRI: a review of the clinical literature, Br J Radiol, vol.88, issue.1056, 2015.

P. Lanzer, C. Barta, E. H. Botvinick, H. U. Wiesendanger, G. Modin et al., ECG-synchronized cardiac MR imaging: method and evaluation, Radiology, vol.155, issue.3, pp.681-686, 1985.

R. L. Ehman and J. P. Felmlee, Adaptive technique for high-definition MR imaging of moving structures, Radiology, vol.173, issue.1, pp.255-263, 1989.

K. Nehrke, P. Börnert, D. Manke, and J. C. Böck, Free-breathing Cardiac MR Imaging: Study of Implications of Respiratory Motion-Initial Results, Radiology, vol.220, issue.3, pp.810-815, 2001.

G. J. Pelgrim, Quantitative Myocardial Perfusion with Dynamic Contrast-Enhanced Imaging in MRI and CT: Theoretical Models and Current Implementation, BioMed Research International, vol.2016, p.1734190, 2016.

A. M. Segura, O. H. Frazier, and L. M. Buja, Fibrosis and heart failure, Heart Fail Rev, vol.19, issue.2, pp.173-185, 2014.

F. Zannad, P. Rossignol, and W. Iraqi, Extracellular matrix fibrotic markers in heart failure, Heart Fail Rev, vol.15, issue.4, pp.319-329, 2010.

S. R. Eckhouse and F. G. Spinale, Changes in the Myocardial Interstitium and Contribution to the Progression of Heart Failure, Heart Fail Clin, vol.8, issue.1, pp.7-20, 2012.

E. Braunwald, Heart failure, JACC Heart Fail, vol.1, issue.1, pp.1-20, 2013.

, Atlas de poche de physiologie 3e édition -Agamemnon Despopoulos,Stefan Silbernagl

E. Calzia, Z. Iványi, and P. Radermacher, Determinants of Blood Flow and Organ Perfusion, Functional Hemodynamic Monitoring, vol.42, pp.19-32, 2005.

C. A. Cuenod and D. Balvay, Perfusion and vascular permeability: Basic concepts and measurement in DCE-CT and DCE-MRI, Diagnostic and Interventional Imaging, vol.94, issue.12, pp.1187-1204, 2013.

K. P. Schäfers, Absolute Quantification of Myocardial Blood Flow with H215O and 3-Dimensional PET: An Experimental Validation, J Nucl Med, vol.43, issue.8, pp.1031-1040, 2002.

P. Ponikowski, 2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure: The Task Force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC)Developed with the special contribution of the Heart Failure Association (HFA) of the ESC, European Heart Journal, vol.37, issue.27, pp.2129-2200, 2016.

T. S. Investigators and *. , Effect of Enalapril on Mortality and the Development of Heart Failure in Asymptomatic Patients with Reduced Left Ventricular Ejection Fractions, 2010.

R. Eschalier, Fibrose et insuffisance cardiaque, 2013.
URL : https://hal.archives-ouvertes.fr/tel-01165263

M. Gyöngyösi, Myocardial fibrosis: biomedical research from bench to bedside, Eur J Heart Fail, vol.19, issue.2, pp.177-191, 2017.

A. Mosterd and A. W. Hoes, Clinical epidemiology of heart failure, Heart, vol.93, issue.9, pp.1137-1146, 2007.

G. S. Bleumink, Quantifying the heart failure epidemic: prevalence, incidence rate, lifetime risk and prognosis of heart failureThe Rotterdam Study, Eur Heart J, vol.25, issue.18, pp.1614-1619, 2004.

A. Gabet, Y. Juillière, A. Lamarche-vadel, M. Vernay, and V. Olié, National trends in rate of patients hospitalized for heart failure and heart failure mortality in France, European Journal of Heart Failure, vol.17, issue.6, pp.583-590, 2000.

P. Tuppin, Prevalence and economic burden of cardiovascular diseases in France in 2013 according to the national health insurance scheme database, Archives of Cardiovascular Diseases, vol.109, issue.6, pp.399-411, 2016.

V. Monceau, E. Camors, and D. Charlemagne, Physiopathologie du remodelage ventriculaire, MT Cardio, vol.2, issue.3, pp.273-279, 2006.

P. S. Azevedo, B. F. Polegato, M. F. Minicucci, S. A. Paiva, and L. A. Zornoff, Cardiac Remodeling: Concepts, Clinical Impact, Pathophysiological Mechanisms and Pharmacologic Treatment, Arq Bras Cardiol, vol.106, issue.1, pp.62-69, 2016.

J. Samuel and C. Delcayre, La fibrose cardiaque, Bulletin de l'Académie Nationale de Médecine, vol.201, issue.4-6, pp.30460-30461, 2017.

C. G. Brilla and K. T. Weber, Reactive and reparative myocardial fibrosis in arterial hypertension in the rat, Cardiovasc Res, vol.26, issue.7, pp.671-677, 1992.

D. A. Bluemke and P. Pattanayak, TISSUE CHARACTERIZATION OF THE MYOCARDIUM : STATE OF THE ART CHARACTERIZATION BY MR AND CT IMAGING, Radiol Clin North Am, vol.53, issue.2, pp.413-423, 2015.

L. Iles, Evaluation of Diffuse Myocardial Fibrosis in Heart Failure With Cardiac Magnetic Resonance Contrast-Enhanced T1 Mapping, Journal of the American College of Cardiology, vol.52, issue.19, pp.1574-1580, 2008.

D. J. Pennell, Clinical indications for cardiovascular magnetic resonance (CMR): Consensus Panel report, Eur Heart J, vol.25, issue.21, pp.1940-1965, 2004.

M. Salerno, Comparison of Methods for Determining the Partition Coefficient of Gadolinium in the Myocardium Using T1 Mapping, J Magn Reson Imaging, vol.38, issue.1, pp.217-224, 2013.

M. Saeed, T. A. Van, R. Krug, S. W. Hetts, and M. W. Wilson, Cardiac MR imaging: current status and future direction, Cardiovasc Diagn Ther, vol.5, issue.4, pp.290-310, 2015.

V. O. Puntmann, Society for Cardiovascular Magnetic Resonance (SCMR) expert consensus for CMR imaging endpoints in clinical research: part I -analytical validation and clinical qualification, Journal of Cardiovascular Magnetic Resonance, vol.20, issue.1, p.67, 2018.

C. M. Kramer, J. Barkhausen, S. D. Flamm, R. J. Kim, and E. Nagel, Standardized cardiovascular magnetic resonance imaging (CMR) protocols, society for cardiovascular magnetic resonance: board of trustees task force on standardized protocols, Journal of Cardiovascular Magnetic Resonance, vol.10, issue.1, p.35, 2008.

S. Fratz, Guidelines and protocols for cardiovascular magnetic resonance in children and adults with congenital heart disease: SCMR expert consensus group on congenital heart disease, J Cardiovasc Magn Reson, vol.15, issue.1, p.51, 2013.

W. G. Hundley, Society for Cardiovascular Magnetic Resonance guidelines for reporting cardiovascular magnetic resonance examinations, J Cardiovasc Magn Reson, vol.11, issue.1, 2009.

H. J. Gomes, V. De-padua-vieira-alves, and M. S. Nacif, The Value of T1 Mapping Techniques in the Assessment of Myocardial Interstitial Fibrosis, Magnetic Resonance Imaging Clinics of North America, vol.27, issue.3, pp.563-574, 2019.

A. A. Robinson, K. Chow, and M. Salerno, Myocardial T1 and ECV Measurement: Underlying Concepts and Technical Considerations, J Am Coll Cardiol Img, vol.12, issue.11, pp.2332-2344, 2019.

G. Reiter, C. Reiter, C. Kräuter, M. Fuchsjäger, and U. Reiter, Cardiac magnetic resonance T1 mapping. Part 1: Aspects of acquisition and evaluation, European Journal of Radiology, vol.109, pp.223-234, 2018.

U. Reiter, C. Reiter, C. Kräuter, M. Fuchsjäger, and G. Reiter, Cardiac magnetic resonance T1 mapping. Part 2: Diagnostic potential and applications, European Journal of Radiology, vol.109, pp.235-247, 2018.

P. Haaf, P. Garg, D. R. Messroghli, D. A. Broadbent, J. P. Greenwood et al., Cardiac T1 Mapping and Extracellular Volume (ECV) in clinical practice: a comprehensive review, Journal of Cardiovascular Magnetic Resonance, vol.18, issue.1, 2017.

D. Radenkovic, S. Weingärtner, L. Ricketts, J. C. Moon, and G. Captur, T1 mapping in cardiac MRI, Heart Fail Rev, vol.22, issue.4, pp.415-430, 2017.

S. K. Piechnik and M. Jerosch-herold, Myocardial T1 mapping and extracellular volume quantification: an overview of technical and biological confounders, Int J Cardiovasc Imaging, vol.34, issue.1, pp.3-14, 2018.

E. B. Schelbert and D. R. Messroghli, State of the art: clinical applications of cardiac T1 mapping, Radiology, vol.278, issue.3, pp.658-676, 2016.

S. , Accuracy, precision, and reproducibility of four T1 mapping sequences: a head-to-head comparison of MOLLI, ShMOLLI, SASHA, and SAPPHIRE, Radiology, vol.272, issue.3, pp.683-689, 2014.

P. Kellman and M. S. Hansen, T1-mapping in the heart: accuracy and precision, J Cardiovasc Magn Reson, vol.16, issue.2, p.7, 2014.

S. K. White, T1 Mapping for Myocardial Extracellular Volume Measurement by CMR, JACC: Cardiovascular Imaging, vol.6, issue.9, pp.955-962, 2013.

H. M. Cheng and G. A. Wright, Rapid high-resolutionT1 mapping by variable flip angles: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity, Magnetic Resonance in Medicine, vol.55, issue.3, pp.566-574, 2006.

H. Clique, H. M. Cheng, P. Marie, J. Felblinger, and M. Beaumont, 3D myocardial T1 mapping at 3T using variable flip angle method: Pilot study, Magnetic Resonance in Medicine, vol.71, issue.2, pp.823-829, 2014.
URL : https://hal.archives-ouvertes.fr/hal-01726409

S. Weingärtner, Combined saturation/inversion recovery sequences for improved evaluation of scar and diffuse fibrosis in patients with arrhythmia or heart rate variability, Magnetic Resonance in Medicine, vol.71, issue.3, pp.1024-1034, 2014.

J. I. Hamilton, MR Fingerprinting for Rapid Quantification of Myocardial T1, T2, and Proton Spin Density, Magn Reson Med, vol.77, issue.4, pp.1446-1458, 2017.

A. G. Christodoulou, Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging, Nat Biomed Eng, vol.2, issue.4, pp.215-226, 2018.

D. C. Look and D. R. Locker, Time Saving in Measurement of NMR and EPR Relaxation Times, Review of Scientific Instruments, vol.41, issue.2, pp.250-251, 1970.

M. Gottbrecht, C. M. Kramer, and M. Salerno, Native T1 and Extracellular Volume Measurements by Cardiac MRI in Healthy Adults: A Meta-Analysis, Radiology, vol.290, issue.2, pp.317-326, 2019.

C. M. Kramer, J. Barkhausen, C. Bucciarelli-ducci, S. D. Flamm, R. J. Kim et al., Standardized cardiovascular magnetic resonance imaging (CMR) protocols: 2020 update, Journal of Cardiovascular Magnetic Resonance, vol.22, issue.1, p.17, 2020.

P. Kellman, J. R. Wilson, H. Xue, M. Ugander, and A. E. Arai, Extracellular volume fraction mapping in the myocardium, part 1: evaluation of an automated method, Journal of Cardiovascular Magnetic Resonance, vol.14, issue.1, p.63, 2012.

S. K. Piechnik, Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold, Journal of cardiovascular magnetic resonance, vol.12, issue.1, p.69, 2010.

P. Kellman and A. E. Arai, Cardiac imaging techniques for physicians: Late enhancement, Journal of Magnetic Resonance Imaging, vol.36, issue.3, pp.529-542, 2012.

C. L. Jellis and D. H. Kwon, Myocardial T1 mapping: modalities and clinical applications, Cardiovascular diagnosis and therapy, vol.4, issue.2, pp.126-137, 2013.

E. Kehr, M. Sono, S. S. Chugh, and M. Jerosch-herold, Gadolinium-enhanced magnetic resonance imaging for detection and quantification of fibrosis in human myocardium in vitro, Int J Cardiovasc Imaging, vol.24, issue.1, pp.61-68, 2008.

P. A. Harris, C. H. Lorenz, G. E. Holburn, and K. A. Overholser, Regional measurement of the Gd-DTPA tissue partition coefficient in canine myocardium, Magnetic Resonance in Medicine, vol.38, issue.4, pp.541-545, 1997.

S. S. Kety, The Theory and Applications of the Exchange of Inert Gas at the Lungs and Tissues, Pharmacol Rev, vol.3, issue.1, pp.1-41, 1951.

J. C. Moon, Myocardial T1 mapping and extracellular volume quantification: a Society for Cardiovascular Magnetic Resonance (SCMR) and CMR Working Group of the European Society of Cardiology consensus statement, J Cardiovasc Magn Reson, vol.15, issue.1, p.92, 2013.

M. Jerosch-herold, Cardiac magnetic resonance imaging of myocardial contrast uptake and blood flow in patients affected with idiopathic or familial dilated cardiomyopathy, American Journal of Physiology-Heart and Circulatory Physiology, vol.295, issue.3, pp.1234-1242, 2008.

T. A. Treibel, 29 Synthetic ECV -simplifying ECV quantification by deriving haematocrit from T1 blood, Heart, vol.101, issue.2, pp.16-17, 2015.

T. A. Treibel, Automatic Measurement of the Myocardial Interstitium: Synthetic Extracellular Volume Quantification Without Hematocrit Sampling, JACC: Cardiovascular Imaging, vol.9, issue.1, pp.54-63, 2016.

Y. Shang, X. Zhang, X. Zhou, and J. Wang, Extracellular volume fraction measurements derived from the longitudinal relaxation of blood-based synthetic hematocrit may lead to clinical errors in 3 T cardiovascular magnetic resonance, Journal of Cardiovascular Magnetic Resonance, vol.20, issue.1, p.56, 2018.

H. Xue, Unsupervised Inline Analysis of Cardiac Perfusion MRI, Medical Image Computing and Computer-Assisted Intervention -MICCAI, pp.741-749, 2009.

S. Tilborghs, Robust Model-Based Registration of Cardiac MR Images for T1 and ECV Mapping, Functional Imaging and Modelling of the Heart, pp.42-50, 2017.

F. Andrew and S. , Equilibrium Contrast Cardiovascular Magnetic Resonance for the Measurement of Diffuse Myocardial Fibrosis, Circulation, vol.122, issue.2, pp.138-144, 2010.

M. Fontana, Comparison of T1 mapping techniques for ECV quantification. Histological validation and reproducibility of ShMOLLI versus multibreath-hold T1 quantification equilibrium contrast CMR, J Cardiovasc Magn Reson, vol.14, issue.1, p.88, 2012.

D. Nordlund, Measuring extracellular volume fraction by MRI: First verification of values given by clinical sequences, Magnetic Resonance in Medicine, vol.83, issue.2, pp.662-672, 2020.

A. A. Robinson, K. Chow, and M. Salerno, Myocardial T1 and ECV Measurement, JACC: Cardiovascular Imaging, vol.12, issue.11, pp.2332-2344, 2019.

C. De-meester-de-ravenstein, Histological Validation of measurement of diffuse interstitial myocardial fibrosis by myocardial extravascular volume fraction from Modified Look-Locker imaging (MOLLI) T1 mapping at 3 T, J Cardiovasc Magn Reson, vol.17, issue.1, 2015.

K. P. Kunze, Quantitative cardiovascular magnetic resonance: extracellular volume, native T1 and 18F-FDG PET/CMR imaging in patients after revascularized myocardial infarction and association with markers of myocardial damage and systemic inflammation, Journal of Cardiovascular Magnetic Resonance, vol.20, 2018.

R. Hinojar, T1 Mapping in Discrimination of Hypertrophic Phenotypes: Hypertensive Heart Disease and Hypertrophic Cardiomyopathy Findings From the International T1 Multicenter Cardiovascular Magnetic Resonance Study, Circulation: Cardiovascular Imaging, vol.8, issue.12, p.3285, 2015.

D. J. Atkinson, D. Burstein, and R. R. Edelman, First-pass cardiac perfusion: evaluation with ultrafast MR imaging, Radiology, vol.174, issue.3, pp.757-762, 1990.

N. Eike, Magnetic Resonance Perfusion Measurements for the Noninvasive Detection of Coronary Artery Disease, Circulation, vol.108, issue.4, pp.432-437, 2003.

K. Francis and J. , Limits of Detection of Regional Differences in Vasodilated Flow in Viable Myocardium by First-Pass Magnetic Resonance Perfusion Imaging, Circulation, vol.104, issue.20, pp.2412-2416, 2001.

T. Ibrahim, Assessment of coronary flow reserve: comparison between contrast-enhanced magnetic resonance imaging and positron emission tomography, Journal of the American College of Cardiology, vol.39, issue.5, pp.864-870, 2002.

J. P. Greenwood, Cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary heart disease (CE-MARC): a prospective trial, Lancet, vol.379, issue.9814, pp.61335-61339, 2012.

K. L. Zierler, Theoretical Basis of Indicator-Dilution Methods For Measuring Flow and Volume, Circulation Research, vol.10, issue.3, pp.393-407, 1962.

S. P. Sourbron and D. L. Buckley, Classic models for dynamic contrast-enhanced MRI: CLASSIC MODELS FOR DCE-MRI, NMR in Biomedicine, vol.26, issue.8, pp.1004-1027, 2013.

M. Jerosch-herold, Quantification of myocardial perfusion by cardiovascular magnetic resonance, J Cardiovasc Magn Reson, vol.12, issue.1, p.57, 2010.

M. Jerosch-herold, R. T. Seethamraju, C. M. Swingen, N. M. Wilke, and A. E. Stillman, Analysis of myocardial perfusion MRI, Journal of Magnetic Resonance Imaging, vol.19, issue.6, pp.758-770, 2004.

L. Hsu, Diagnostic Performance of Fully Automated Pixel-Wise Quantitative Myocardial Perfusion Imaging by Cardiovascular Magnetic Resonance, JACC: Cardiovascular Imaging, vol.11, issue.5, pp.697-707, 2018.

L. Hsu, D. W. Groves, A. H. Aletras, P. Kellman, and A. E. Arai, A Quantitative Pixel-Wise Measurement of Myocardial Blood Flow by Contrast-Enhanced First-Pass CMR Perfusion Imaging: Microsphere Validation in Dogs and Feasibility Study in Humans, JACC: Cardiovascular Imaging, vol.5, issue.2, pp.154-166, 2012.

T. H. Giang, Detection of coronary artery disease by magnetic resonance myocardial perfusion imaging with various contrast medium doses: first european multi-centre experience, Eur Heart J, vol.25, issue.18, pp.1657-1665, 2004.

L. Hsu, K. L. Rhoads, J. E. Holly, P. Kellman, A. H. Aletras et al., Quantitative myocardial perfusion analysis with a dual-bolus contrast-enhanced first-pass MRI technique in humans, J Magn Reson Imaging, vol.23, issue.3, pp.315-322, 2006.

C. A. Miller, Voxel-wise quantification of myocardial blood flow with cardiovascular magnetic resonance: effect of variations in methodology and validation with positron emission tomography, Journal of Cardiovascular Magnetic Resonance, vol.16, issue.1, p.11, 2014.

P. S. Tofts and A. G. Kermode, Measurement of the blood-brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental concepts, Magn. Reson. Med, vol.17, issue.2, pp.357-367, 1991.

P. S. Tofts, Estimating kinetic parameters from dynamic contrast-enhanced t1-weighted MRI of a diffusable tracer: Standardized quantities and symbols, J

, Magn. Reson. Imaging, vol.10, issue.3, pp.223-232, 1999.

S. P. Sourbron and D. L. Buckley, On the scope and interpretation of the Tofts models for DCE-MRI, Magnetic Resonance in Medicine, vol.66, issue.3, pp.735-745, 2011.

P. S. Tofts, Modeling tracer kinetics in dynamic Gd-DTPA MR imaging, Journal of Magnetic Resonance Imaging, vol.7, issue.1, pp.91-101, 1997.

N. A. Pack, E. V. Dibella, B. D. Wilson, and C. J. Mcgann, Quantitative myocardial distribution volume from dynamic contrast-enhanced MRI, Magnetic Resonance Imaging, vol.26, issue.4, pp.532-542, 2008.

B. James and B. , A Concurrent Flow Model for Extraction during Transcapillary Passage, Circulation Research, vol.35, issue.3, pp.483-503, 1974.

J. B. Bassingthwaighte, C. Y. Wang, and I. S. Chan, Blood-Tissue Exchange via Transport and Transformation by Capillary Endothelial Cells, Circ Res, vol.65, issue.4, pp.997-1020, 1989.

P. Kellman, Myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification, Journal of Cardiovascular Magnetic Resonance, vol.19, issue.1, 2017.

L. A. Brown, Fully automated, inline quantification of myocardial blood flow with cardiovascular magnetic resonance: repeatability of measurements in healthy subjects, J Cardiovasc Magn Reson, vol.20, 2018.

H. Engblom, Importance of standardizing timing of hematocrit measurement when using cardiovascular magnetic resonance to calculate myocardial extracellular volume (ECV) based on pre-and post-contrast T1 mapping, J Cardiovasc Magn Reson, vol.20, 2018.

J. R. Alves, R. A. De-queiroz, M. Bär, and R. W. Santos, Simulation of the Perfusion of Contrast Agent Used in Cardiac Magnetic Resonance: A Step Toward Non-invasive Cardiac Perfusion Quantification, Front Physiol, vol.10, 2019.

F. Khalifa, Models and methods for analyzing DCE-MRI: A review, Medical Physics, vol.41, issue.12, p.124301, 2014.

S. P. Sourbron and D. L. Buckley, Tracer kinetic modelling in MRI: estimating perfusion and capillary permeability, Physics in Medicine and Biology, vol.57, issue.2, pp.1-33, 2012.

L. Axel, J. Costantini, and J. Listerud, Intensity correction in surface-coil MR imaging, American Journal of Roentgenology, vol.148, issue.2, pp.418-420, 1987.

E. R. Mcveigh, M. J. Bronskill, and R. M. Henkelman, Phase and sensitivity of receiver coils in magnetic resonance imaging: Phase and sensitivity of receiver coils in MRI, Med. Phys, vol.13, issue.6, pp.806-814, 1986.

U. Vovk, F. Pernus, and B. Likar, A Review of Methods for Correction of Intensity Inhomogeneity in MRI, IEEE Trans. Med. Imaging, vol.26, issue.3, pp.405-421, 2007.

B. K. Wallner, R. R. Edelman, R. L. Bajakian, J. Kleefield, D. J. Atkinson et al., Signal normalization in surface-coil MR imaging, American Journal of Neuroradiology, vol.11, issue.6, pp.1271-1272, 1990.

B. Belaroussi, J. Milles, S. Carme, Y. M. Zhu, and H. Benoit-cattin, Intensity nonuniformity correction in MRI: Existing methods and their validation, Medical Image Analysis, vol.10, issue.2, pp.234-246, 2006.
URL : https://hal.archives-ouvertes.fr/hal-02071614

C. Han, T. S. Hatsukami, and C. Yuan, A multi-scale method for automatic correction of intensity non-uniformity in MR images, Journal of Magnetic Resonance Imaging, vol.13, issue.3, pp.428-436, 2001.

L. Hsu, K. L. Rhoads, A. H. Aletras, and A. E. Arai, Surface Coil Intensity Correction and Non-linear Intensity Normalization Improve Pixel-Resolution Parametric Maps of Myocardial MRI Perfusion, Medical Image Computing and Computer-Assisted Intervention -MICCAI 2003, vol.2879, pp.975-976, 2003.

D. L. Buckley, Uncertainty in the analysis of tracer kinetics using dynamic contrast-enhancedT1-weighted MRI, Magnetic Resonance in Medicine, vol.47, issue.3, pp.601-606, 2002.

R. G. Lopata, W. H. Backes, P. P. Van-den, N. A. Bosch, and . Van-riel, On the identifiability of pharmacokinetic parameters in dynamic contrast-enhanced imaging, Magnetic Resonance in Medicine, vol.58, issue.2, pp.425-429, 2007.

H. J. Aerts, K. Jaspers, and W. H. Backes, The precision of pharmacokinetic parameters in dynamic contrast-enhanced magnetic resonance imaging: the effect of sampling frequency and duration, Phys. Med. Biol, vol.56, issue.17, pp.5665-5678, 2011.

P. S. Tofts, T1-weighted DCE Imaging Concepts: Modelling, Acquisition and Analysis, p.5

R. E. Hendrick and E. , Signal, Noise, Signal-to-Noise, and Contrast-to-Noise Ratios, Breast MRI: Fundamentals and Technical Aspects, pp.93-111, 2008.

G. J. Parker, Experimentally-derived functional form for a populationaveraged high-temporal-resolution arterial input function for dynamic contrastenhanced MRI, Magnetic Resonance in Medicine, vol.56, issue.5, pp.993-1000, 2006.

S. Wang, Arterial input functions (AIFs) measured directly from arteries with low and standard doses of contrast agent, and AIFs derived from reference tissues, Magn Reson Imaging, vol.34, issue.2, pp.197-203, 2016.

P. Wedeking, S. Eaton, D. G. Covell, S. Nair, M. F. Tweedle et al., Pharmacokinetic analysis of blood distribution of intravenously administered 153Gd-labeled Gd(DTPA)2? and 99MTc(DTPA) in rats, Magnetic Resonance Imaging, vol.8, issue.5, pp.567-575, 1990.

M. Su, J. Jao, and O. Nalcioglu, Measurement of vascular volume fraction and blood-tissue permeability constants with a pharmacokinetic model: Studies in rat muscle tumors with dynamic Gd-DTPA enhanced MRI, Magnetic Resonance in Medicine, vol.32, issue.6, pp.714-724, 1994.

H. K. Thompson, C. F. Starmer, R. E. Whalen, and H. D. Mcintosh, Indicator Transit Time Considered as a Gamma Variate, Circulation Research, vol.14, issue.6, pp.502-515, 1964.

G. Johnson, S. G. Wetzel, S. Cha, J. Babb, and P. S. Tofts, Measuring blood volume and vascular transfer constant from dynamic, T-weighted contrast-enhanced MRI, Magnetic Resonance in Medicine, vol.51, issue.5, pp.961-968, 2004.

V. Patil and G. Johnson, An improved model for describing the contrast bolus in perfusion MRI, Med Phys, vol.38, issue.12, pp.6380-6383, 2011.

D. Balvay, Y. Ponvianne, M. Claudon, and C. Cuenod, Arterial input function: Relevance of eleven analytical models in DCE-MRI studies, Biomedical Imaging: From Nano to Macro, pp.600-603, 2008.

T. Fritz-hansen, J. D. Hove, K. F. Kofoed, H. Kelbaek, and H. B. Larsson, Quantification of MRI measured myocardial perfusion reserve in healthy humans: A comparison with positron emission tomography, Journal of Magnetic Resonance Imaging, vol.27, issue.4, pp.818-824, 2008.

E. Henderson, B. K. Rutt, and T. Lee, Temporal sampling requirements for the tracer kinetics modeling of breast disease, Magnetic Resonance Imaging, vol.16, issue.9, pp.1057-1073, 1998.

C. R. Planey, Temporal Sampling Requirements for Reference Region Modeling of DCE-MRI Data in Human Breast Cancer, J Magn Reson Imaging, vol.30, issue.1, pp.121-134, 2009.

J. U. Fluckiger, M. C. Schabel, and E. V. Dibella, The effect of temporal sampling on quantitative pharmacokinetic and three-time-point analysis of breast DCE-MRI, Magnetic Resonance Imaging, vol.30, issue.7, pp.934-943, 2012.

R. Luypaert, S. Sourbron, S. Makkat, and J. De-mey, Error estimation for perfusion parameters obtained using the two-compartment exchange model in dynamic contrastenhanced MRI: a simulation study, Phys. Med. Biol, vol.55, issue.21, pp.6431-6443, 2010.

R. Luypaert, S. Sourbron, and J. De-mey, Validity of perfusion parameters obtained using the modified Tofts model: A simulation study, Magnetic Resonance in Medicine, vol.65, issue.5, pp.1491-1497, 2011.

M. B. Hansen, Robust estimation of hemo-dynamic parameters in traditional DCE-MRI models, PLoS One, vol.14, issue.1, 2019.

M. F. Wendland, Inversion recovery EPI of bolus transit in rat myocardium using intravascular and extravascular gadolinium-based MR contrast media: Dose effects on peak signal enhancement, Magnetic Resonance in Medicine, vol.32, issue.3, pp.319-329, 1994.

C. Duan, J. F. Kallehauge, G. L. Bretthorst, K. Tanderup, J. J. Ackerman et al., Are complex DCE-MRI models supported by clinical data?, Magnetic Resonance in Medicine, vol.77, issue.3, pp.1329-1339, 2017.

P. Kellman, A. H. Aletras, L. Hsu, E. R. Mcveigh, and A. E. Arai, T2 * Measurement During First-Pass Contrast-Enhanced Cardiac Perfusion Imaging, Magn Reson Med, vol.56, issue.5, pp.1132-1134, 2006.

T. P. Roberts, Physiologic measurements by contrast-enhanced MR imaging: Expectations and limitations, Journal of Magnetic Resonance Imaging, vol.7, issue.1, pp.82-90, 1997.

M. Ingrisch and S. Sourbron, Tracer-kinetic modeling of dynamic contrastenhanced MRI and CT: a primer, J Pharmacokinet Pharmacodyn, vol.40, issue.3, pp.281-300, 2013.

J. D. Biglands, D. R. Magee, S. P. Sourbron, S. Plein, J. P. Greenwood et al., Comparison of the Diagnostic Performance of Four Quantitative Myocardial Perfusion Estimation Methods Used in Cardiac MR Imaging: CE-MARC Substudy, Radiology, vol.275, issue.2, pp.393-402, 2015.

T. F. Christian, Absolute Myocardial Perfusion in Canines Measured by Using Dual-Bolus First-Pass MR Imaging, Radiology, vol.232, issue.3, pp.677-684, 2004.

T. F. Christian, A. H. Aletras, and A. E. Arai, Estimation of absolute myocardial blood flow during first-pass MR perfusion imaging using a dual-bolus injection technique: Comparison to single-bolus injection method, Journal of Magnetic Resonance Imaging, vol.27, issue.6, pp.1271-1277, 2008.

M. Ishida, Development of a universal dual-bolus injection scheme for the quantitative assessment of myocardial perfusion cardiovascular magnetic resonance, J Cardiovasc Magn Reson, vol.13, issue.1, p.28, 2011.

C. M. Scannell, A. Chiribiri, A. D. Villa, M. Breeuwer, and J. Lee, Hierarchical Bayesian myocardial perfusion quantification, Med Image Anal, vol.58, 2020.

K. Sekihara, Steady-State Magnetizations in Rapid NMR Imaging Using Small Flip Angles and Short Repetition Intervals, IEEE Transactions on Medical Imaging, vol.6, issue.2, pp.157-164, 1987.

A. Cernicanu and L. , Theory-Based Signal Calibration with Single-Point T1 Measurements for First-Pass Quantitative Perfusion MRI Studies, Academic Radiology, vol.13, issue.6, pp.686-693, 2006.

P. D. Gatehouse, A. G. Elkington, N. A. Ablitt, G. Yang, D. J. Pennell et al., Accurate assessment of the arterial input function during high-dose myocardial perfusion cardiovascular magnetic resonance, Journal of Magnetic Resonance Imaging, vol.20, issue.1, pp.39-45, 2004.

A. G. Elkington, T. He, P. D. Gatehouse, S. K. Prasad, D. N. Firmin et al., Optimization of the arterial input function for myocardial perfusion cardiovascular magnetic resonance, Journal of Magnetic Resonance Imaging, vol.21, issue.4, pp.354-359, 2005.

D. Kim and L. , Multislice, dual-imaging sequence for increasing the dynamic range of the contrast-enhanced blood signal and CNR of myocardial enhancement at 3T, Journal of Magnetic Resonance Imaging, vol.23, issue.1, pp.81-86, 2006.

K. Chow, Saturation pulse design for quantitative myocardial T1 mapping, J Cardiovasc Magn Reson, vol.17, 2015.

J. Pauly, P. L. Roux, D. Nishimura, and A. Macovski, Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm (NMR imaging), IEEE Transactions on Medical Imaging, vol.10, issue.1, pp.53-65, 1991.

P. P. Ferry, Caractérisation et optimisation d'une méthode de mesure du T1 en IRM cardiaque, p.233

H. M. Cheng, Investigation and optimization of parameter accuracy in dynamic contrast-enhanced MRI, Journal of Magnetic Resonance Imaging, vol.28, issue.3, pp.736-743, 2008.

C. Cuenod and D. Balvay, Imagerie de la perfusion tissulaire et de la perméabilité, Journal de Radiologie Diagnostique et Interventionnelle, vol.94, issue.12, pp.1184-1202, 2013.

M. Azahaf, Impact of arterial input function selection on the accuracy of dynamic contrast-enhanced MRI quantitative analysis for the diagnosis of clinically significant prostate cancer, Journal of Magnetic Resonance Imaging, vol.43, issue.3, pp.737-749, 2016.

, Myocardial Characterization of Arrhythmogenic Mitral Valve Prolapse (STAMP: STretch and Myocardial Characterization in Arrhythmogenic Mitral Valve Prolapse)

F. Calamante, L. Willats, D. G. Gadian, and A. Connelly, Bolus delay and dispersion in perfusion MRI: Implications for tissue predictor models in stroke, Magn. Reson. Med, vol.55, issue.5, pp.1180-1185, 2006.

F. Calamante, Arterial input function in perfusion MRI: A comprehensive review, Progress in Nuclear Magnetic Resonance Spectroscopy, vol.74, pp.1-32, 2013.

T. Kim, N. A. Pack, L. Chen, and E. V. Dibella, Quantification of myocardial perfusion using CMR with a radial data acquisition: comparison with a dual-bolus method, J Cardiovasc Magn Reson, vol.12, issue.1, p.45, 2010.

E. G. Kholmovski and E. V. Dibella, Perfusion MRI with radial acquisition for arterial input function assessment, Magnetic Resonance in Medicine, vol.57, issue.5, pp.821-827, 2007.

J. U. Fluckiger, M. C. Schabel, and E. V. Dibella, Constrained Estimation of the Arterial Input Function for Myocardial Perfusion Cardiovascular Magnetic Resonance, Magn Reson Med, vol.66, issue.2, pp.419-427, 2011.

D. He, L. Xu, W. Qian, J. Clarke, and X. Fan, A simulation study comparing nine mathematical models of arterial input function for dynamic contrast enhanced MRI to the Parker model, Australas Phys Eng Sci Med, vol.41, issue.2, pp.507-518, 2018.

G. J. Stanisz and R. M. Henkelman, Gd-DTPA relaxivity depends on macromolecular content, Magnetic Resonance in Medicine, vol.44, issue.5, pp.665-667, 2000.

M. Rohrer, H. Bauer, J. Mintorovitch, M. Requardt, and H. Weinmann, Comparison of Magnetic Properties of MRI Contrast Media Solutions at Different Magnetic Field Strengths, Investigative Radiology, vol.40, issue.11, pp.715-724, 2005.

I. M. Noebauer-huhmann, P. Szomolanyi, V. Juras, O. Kraff, M. E. Ladd et al., Gadolinium-Based Magnetic Resonance Contrast Agents at 7 Tesla: In Vitro T1 Relaxivities in Human Blood Plasma, vol.45, p.554, 2010.

Y. Shen, T1 Relaxivities of Gadolinium-Based Magnetic Resonance Contrast Agents in Human Whole Blood at 1.5, 3, and 7 T, Investigative Radiology, vol.50, issue.5, pp.330-338, 2015.

M. C. Schabel and D. L. Parker, Uncertainty and bias in contrast concentration measurements using spoiled gradient echo pulse sequences, Phys Med Biol, vol.53, issue.9, pp.2345-2373, 2008.

A. Garpebring, Contributions to Quantitative Dynamic Contrast-Enhanced MRI, p.127

R. Deichmann and A. Haase, Quantification of T1 values by SNAPSHOT-FLASH NMR imaging, Journal of Magnetic Resonance, vol.96, issue.3, pp.608-612, 1969.

D. R. Messroghli, Clinical recommendations for cardiovascular magnetic resonance mapping of T1, T2, T2* and extracellular volume: A consensus statement by the Society for Cardiovascular Magnetic Resonance (SCMR) endorsed by the European Association for Cardiovascular Imaging (EACVI), Journal of Cardiovascular Magnetic Resonance, vol.19, issue.1, p.75, 2017.

C. T. Sibley, Myocardial and blood T1 quantification in normal volunteers at 3T, J Cardiovasc Magn Reson, vol.13, p.51, 2011.

J. F. Heidenreich, T1-and ECV-mapping in clinical routine at 3 T: differences between MOLLI, ShMOLLI and SASHA, BMC Medical Imaging, vol.19, issue.1, p.59, 2019.

N. Cîndea, F. Odille, G. Bosser, J. Felblinger, and P. Vuissoz, Reconstruction from free-breathing cardiac MRI data using reproducing kernel Hilbert spaces, Magnetic Resonance in Medicine, vol.63, issue.1, pp.59-67, 2010.

S. Thesen, O. Heid, E. Mueller, and L. R. Schad, Prospective acquisition correction for head motion with image-based tracking for real-time fMRI, Magnetic Resonance in Medicine, vol.44, issue.3, pp.457-465, 2000.

S. Klein, M. Staring, K. Murphy, M. A. Viergever, and J. Pluim, elastix: A Toolbox for Intensity-Based Medical Image Registration, IEEE Trans. Med. Imaging, vol.29, issue.1, pp.196-205, 2010.

P. Kellman, C. Chefd'hotel, C. H. Lorenz, C. Mancini, A. E. Arai et al., Fully automatic, retrospective enhancement of real-time acquired cardiac cine MR images using image-based navigators and respiratory motion-corrected averaging, Magnetic Resonance in Medicine, vol.59, issue.4, pp.771-778, 2008.

S. Roujol, M. Foppa, S. Weingärtner, W. J. Manning, and R. Nezafat, Adaptive registration of varying contrast-weighted images for improved tissue characterization (ARCTIC): Application to T1 mapping, Magnetic Resonance in Medicine, vol.73, issue.4, pp.1469-1482, 2015.

Q. Tao, P. Van-der-tol, F. F. Berendsen, E. H. Paiman, H. J. Lamb et al., Robust motion correction for myocardial T1 and extracellular volume mapping by principle component analysis-based groupwise image registration, Journal of Magnetic Resonance Imaging, vol.47, issue.5, pp.1397-1405, 2018.

J. Milles, R. J. Van-der-geest, M. Jerosch-herold, J. H. Reiber, and B. P. Lelieveldt, Fully Automated Motion Correction in First-Pass Myocardial Perfusion MR Image Sequences, IEEE Transactions on Medical Imaging, vol.27, issue.11, pp.1611-1621, 2008.

B. Pontré, An Open Benchmark Challenge for Motion Correction of Myocardial Perfusion MRI, IEEE Journal of Biomedical and Health Informatics, vol.21, issue.5, pp.1315-1326, 2017.

S. Zhang, Cardiac magnetic resonance T1 and extracellular volume mapping with motion correction and co-registration based on fast elastic image registration, MAGMA, vol.31, issue.1, pp.115-129, 2018.

M. J. Ledesma-carbayo, P. Kellman, A. E. Arai, and E. R. Mcveigh, Motion corrected free-breathing delayed-enhancement imaging of myocardial infarction using nonrigid registration, Journal of Magnetic Resonance Imaging, vol.26, issue.1, pp.184-190, 2007.

G. Adluru, E. V. Dibella, and M. C. Schabel, Model-based registration for dynamic cardiac perfusion MRI, Journal of Magnetic Resonance Imaging, vol.24, issue.5, pp.1062-1070, 2006.

M. Benovoy, M. Jacobs, F. Cheriet, N. Dahdah, A. E. Arai et al., A Robust Universal Nonrigid Motion Correction Framework for First-Pass Cardiac Magnetic Resonance Perfusion Imaging, J Magn Reson Imaging, vol.46, issue.4, pp.1060-1072, 2017.

V. Hamy, Respiratory motion correction in dynamic MRI using robust data decomposition registration -Application to DCE-MRI, Medical Image Analysis, vol.18, issue.2, pp.301-313, 2014.

A. Myronenko and X. Song, Intensity-Based Image Registration by Minimizing Residual Complexity, IEEE Transactions on Medical Imaging, vol.29, issue.11, pp.1882-1891, 2010.

B. K. Horn and B. G. Schunck, Determining Optical Flow, p.19

A. Mehrtash, Bolus arrival time and its effect on tissue characterization with dynamic contrast-enhanced magnetic resonance imaging, J Med Imaging (Bellingham), vol.3, issue.1, 2016.

A. Sotiras, C. Davatzikos, and N. Paragios, Deformable Medical Image Registration: A Survey, IEEE Transactions on Medical Imaging, vol.32, issue.7, pp.1153-1190, 2013.
URL : https://hal.archives-ouvertes.fr/hal-00684715

A. Menys, Dual registration of abdominal motion for motility assessment in free-breathing data sets acquired using dynamic MRI, Phys. Med. Biol, vol.59, issue.16, pp.4603-4619, 2014.

Q. Feng, Liver DCE-MRI Registration in Manifold Space Based on Robust Principal Component Analysis, Scientific Reports, vol.6, p.34461, 2016.

C. M. Scannell, A. D. Villa, J. Lee, M. Breeuwer, and A. Chiribiri, Robust Non-Rigid Motion Compensation of Free-Breathing Myocardial Perfusion MRI Data, IEEE Transactions on Medical Imaging, vol.38, issue.8, pp.1812-1820, 2019.

M. Salerno, Recent Advances in Cardiovascular Magnetic Resonance Techniques and Applications, Circ Cardiovasc Imaging, vol.10, issue.6, 2017.

R. Zhou, Simple motion correction strategy reduces respiratory-induced motion artifacts for k-t accelerated and compressed-sensing cardiovascular magnetic resonance perfusion imaging, Journal of Cardiovascular Magnetic Resonance, vol.20, issue.1, 2018.

R. J. Kim, D. J. Shah, and R. M. Judd, How we perform delayed enhancement imaging, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, vol.5, issue.3, pp.505-514, 2003.

M. C. Dulce, MR imaging of the myocardium using nonionic contrast medium: signal-intensity changes in patients with subacute myocardial infarction, American Journal of Roentgenology, vol.160, issue.5, pp.963-970, 1993.

L. E. Thomson, R. J. Kim, and R. M. Judd, Magnetic resonance imaging for the assessment of myocardial viability, Journal of Magnetic Resonance Imaging, vol.19, issue.6, pp.771-788, 2004.

K. P. Kunze, Measurement of extracellular volume and transit time heterogeneity using contrast-enhanced myocardial perfusion MRI in patients after acute myocardial infarction, Magnetic Resonance in Medicine, vol.77, issue.6, pp.2320-2330, 2017.

C. M. Kramer and Y. Chandrashekhar, Quantitative Myocardial Perfusion CMR: Is the Game Worth the Candle?, JACC: Cardiovascular Imaging, vol.11, issue.5, pp.784-786, 2018.

J. Louis, M. Petit, P. Ferry, C. Schaaf, J. Felblinger et al., Multi-site T1 myocardial quantification follow up : phantom design, and multi sequence comparison

J. Weiss and ;. Louis,

, Ahmet AYAV

C. Isabelle and . Urmes,

A. Khalid and . Beaumont,

L. Valérie, MRI characterization of liver focal lesions using T1 mapping and diffusion-weighted imaging

, Céline Vogrig

J. Louis,

F. Avila,

R. Gillet,

A. Blum-moyse,

, Pedro Augusto Gondim Teixeira « Synthetic MR images not yet ready for morphologic and functional assessment of patellar cartilage on 1.5T: a preliminary study, Diagnostic & Interventional Imaging -in revision

J. Louis, F. Odille, D. Mandry, C. D. Chillou, J. Felblinger et al., Evaluation of an abbreviated dynamic contrast enhancement cmri protocol using permeability mapping

J. S. Louis, P. Ferry, J. Poujol, L. Bonnemains, J. Felblinger et al., Wide range T1/T2 phantom conception for a multicenter cardiac clinical trial: DRAGET, Proceeding of the ESMRMB 2016, 33rd Annual Scientific Meeting, vol.185

J. S. Louis, P. Ferry, J. Poujol, L. Bonnemains, J. Felblinger et al., Conception et suivis d'un fantôme de calibration multi-machine T1 et T2 pour l'étude du rejet de greffe cardiaque, 2017.

J. S. Louis, D. Mandry, O. Huttin, C. Selton-suty, J. Felblinger et al., Pixel-wise quantitative permeability and ECV analysis of myocardial tissue in patients with mitral prolapse: a preliminary study, proceeding of the 22 nd Annual meeting of the SCMR, 2019.

J. S. Louis, F. Odille, D. Mandry, J. Felblinger, C. Venner et al., Optimisation d'un algorithme de recalage d'images de perfusion dynamique cardiaque pour l'analyse de la perméabilité myocardique, 2019.

J. S. Louis, F. Odille, D. Mandry, J. Felblinger, C. Venner et al., Myocardial permeability mapping analysis framework with an optimized Residual Complexity based registration, Proceedings of the 27th Annual Meeting of ISMRM, 2019.

J. S. Louis, Cartographie de perméabilité tissulaire : un nouveau biomarqueur d'imagerie de la fibrose myocardique diffuse ?, 2019.