Article Dans Une Revue Sustainability Année : 2021

Improved Adaptive Hamiltonian Control Law for Constant Power Load Stability Issue in DC Microgrid: Case Study for Multiphase Interleaved Fuel Cell Boost Converter

Résumé

The cascaded connection of power converters in a DC microgrid may cause instabilities. Indeed, power converters operating as external loads exhibit constant power load (CPL) behaviors. In this study, the design of the feedback controller of a multi–cell interleaved fuel cell (FC) step–up power circuit is based on the adaptive Hamiltonian control law. It includes two integral terms to confirm that there is no steady-state error in the DC bus voltage, and to guarantee the current balancing of each input inductor current. The design confirms that the desired equilibrium point is (locally) asymptotically stable by using the Lyapunov stability proof. The control approach is validated via digital simulations and experimental tests performed with a 2500 W FC converter supplied by an FC/reformer size of 2500 W and 50 V.
Fichier principal
Vignette du fichier
sustainability-13-08093.pdf (4.85 Mo) Télécharger le fichier
Origine Fichiers éditeurs autorisés sur une archive ouverte

Dates et versions

hal-03293389 , version 1 (21-07-2021)

Licence

Identifiants

Citer

Phatiphat Thounthong, Pongsiri Mungporn, Babak Nahid-Mobarakeh, Nicu Bizon, Serge Pierfederici, et al.. Improved Adaptive Hamiltonian Control Law for Constant Power Load Stability Issue in DC Microgrid: Case Study for Multiphase Interleaved Fuel Cell Boost Converter. Sustainability, 2021, 13 (14), pp.8093. ⟨10.3390/su13148093⟩. ⟨hal-03293389⟩
53 Consultations
59 Téléchargements

Altmetric

Partager

Gmail Mastodon Facebook X LinkedIn More