Fault tolerant operation of single-ended non-isolated DC-DC converters under open and short-circuit switch faults - Université de Lorraine Accéder directement au contenu
Communication Dans Un Congrès Année : 2013

Fault tolerant operation of single-ended non-isolated DC-DC converters under open and short-circuit switch faults

Résumé

Fault tolerant operation of single-ended non-isolated DC-DC converters used in embedded and safety critical applications is mandatory to guaranty service continuity. This paper proposes a new, fast and efficient FPGA-based open and short-circuit switch fault diagnosis asssociated to fault tolerant converter topology. The results of Hardware-In-the-Loop and experimental tests are presented and discussed.
Fichier non déposé

Dates et versions

hal-01384536 , version 1 (20-10-2016)

Identifiants

Citer

Ehsan Jamshidpour, Maryam Shahbazi, Philippe Poure, Eskandar Gholipour, Shahrokh Saadate. Fault tolerant operation of single-ended non-isolated DC-DC converters under open and short-circuit switch faults. EPE 2013, 15th European Conference on Power Electronics and Applications, Sep 2013, Lille, France. pp.4006-4012, ⟨10.1109/EPE.2013.6634471⟩. ⟨hal-01384536⟩
74 Consultations
0 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More