Skip to Main content Skip to Navigation
Journal articles

Hemodynamic and anti-inflammatory effects of early esmolol use in hyperkinetic septic shock: a pilot study

Abstract : Background: Several studies have shown that heart rate control with selective beta-1 blockers in septic shock is safe. In these trials, esmolol was administered 24 h after onset of septic shock in patients who remained tachycardic. While an earlier use of beta-blockers might be beneficial, such use remains challenging due to the difficulty in distinguishing between compensatory and non-compensatory tachycardia. Therefore, the Esmosepsis study was designed to study the effects of esmolol aimed at reducing the heart rate by 20% after the initial resuscitation process in hyperkinetic septic shock patients on (1) cardiac index and (2) systemic and regional hemodynamics as well as inflammatory patterns. Methods: Nine consecutive stabilized tachycardic hyperkinetic septic shock patients treated with norepinephrine for a minimum of 6 h were included. Esmolol was infused during 6 h in order to decrease the heart rate by 20%. The following data were recorded at hours H0 (before esmolol administration), H1-H6 (esmolol administration) and 1 h after esmolol cessation (H7): systolic arterial pressure, diastolic arterial pressure, mean arterial pressure, central venous pressure, heart rate, PICCO transpulmonary thermodilution, sublingual and musculo-cutaneous microcirculation, indocyanine green clearance and echocardiographic parameters, diuresis, lactate, and arterial and venous blood gases. Results: Esmolol was infused 9 (6.4-11.6) hours after norepinephrine introduction. Esmolol was ceased early in 3 out of 9 patients due to a marked increase in norepinephrine requirement associated with a picture of persistent cardiac failure at the lowest esmolol dose. For the global group, during esmolol infusion, norepinephrine infusion increased from 0.49 (0.34-0.83) to 0.78 (0.3-1.11) µg/min/kg. The use of esmolol was associated with a significant decrease in heart rate from 115 (110-125) to 100 (92-103) beats/min and a decrease in cardiac index from 4.2 (3.1-4.4) to 2.9 (2.5-3.7) l/min/m-2. Indexed stroke volume remained unchanged. Cardiac function index and global ejection fraction also markedly decreased. Using echocardiography, systolic, diastolic as well as left and right ventricular function parameters worsened. After esmolol cessation, all parameters returned to baseline values. Lactate and microcirculatory parameters did not change while the majority of pro-inflammatory proteins decreased in all patients. Conclusion: In the very early phase of septic shock, heart rate reduction using fast esmolol titration is associated with an increased risk of hypotension and decreased cardiac index despite maintained adequate tissue perfusion (NCT02068287).
Complete list of metadata

https://hal.univ-lorraine.fr/hal-03109233
Contributor : Erwan Bozec Connect in order to contact the contributor
Submitted on : Wednesday, January 13, 2021 - 4:22:53 PM
Last modification on : Tuesday, February 23, 2021 - 10:42:05 AM
Long-term archiving on: : Wednesday, April 14, 2021 - 6:59:15 PM

File

s13054-020-03445-w.pdf
Publisher files allowed on an open archive

Identifiers

Collections

Citation

Bruno Levy, Caroline Fritz, Caroline Piona, Kévin Duarte, Andrea Morelli, et al.. Hemodynamic and anti-inflammatory effects of early esmolol use in hyperkinetic septic shock: a pilot study. Critical Care, BioMed Central, 2021, 25 (1), pp.21. ⟨10.1186/s13054-020-03445-w⟩. ⟨hal-03109233⟩

Share

Metrics

Record views

137

Files downloads

98