Assessment of cardiac time intervals using high temporal resolution real-time spiral phase contrast with UNFOLDed-SENSE - Université de Lorraine Accéder directement au contenu
Article Dans Une Revue Magnetic Resonance in Medicine Année : 2014

Assessment of cardiac time intervals using high temporal resolution real-time spiral phase contrast with UNFOLDed-SENSE

Résumé

Purpose: To develop a real-time phase contrast MR sequence with high enough temporal resolution to assess cardiac time intervals. Methods: The sequence utilized spiral trajectories with an acquisition strategy that allowed a combination of temporal encoding (Unaliasing by fourier-encoding the overlaps using the temporal dimension; UNFOLD) and parallel imaging (Sensitivity encoding; SENSE) to be used (UNFOLDed-SENSE). An in silico experiment was performed to determine the optimum UNFOLD filter. In vitro experiments were carried out to validate the accuracy of time intervals calculation and peak mean velocity quantification. In addition, 15 healthy volunteers were imaged with the new sequence, and cardiac time intervals were compared to reference standard Doppler echocardiography measures. For comparison, in silico, in vitro, and in vivo experiments were also carried out using sliding window reconstructions. Results: The in vitro experiments demonstrated good agreement between real-time spiral UNFOLDed-SENSE phase contrast MR and the reference standard measurements of velocity and time intervals. The protocol was successfully performed in all volunteers. Subsequent measurement of time intervals produced values in keeping with literature values and good agreement with the gold standard echocardiography. Importantly, the proposed UNFOLDed-SENSE sequence outperformed the sliding window reconstructions. Conclusion: Cardiac time intervals can be successfully assessed with UNFOLDed-SENSE real-time spiral phase contrast. Real-time MR assessment of cardiac time intervals may be beneficial in assessment of patients with cardiac conditions such as diastolic dysfunction.
Fichier principal
Vignette du fichier
mrm.25183.pdf (459.07 Ko) Télécharger le fichier
Origine : Fichiers éditeurs autorisés sur une archive ouverte

Dates et versions

hal-03231720 , version 1 (21-05-2021)

Identifiants

Citer

Grzegorz T Kowalik, Daniel S Knight, Jennifer A Steeden, Oliver Tann, Freddy Odille, et al.. Assessment of cardiac time intervals using high temporal resolution real-time spiral phase contrast with UNFOLDed-SENSE. Magnetic Resonance in Medicine, 2014, 73 (2), pp.749-756. ⟨10.1002/mrm.25183⟩. ⟨hal-03231720⟩
33 Consultations
96 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More