Assessment of PIPE for CO 2 transportation using a constraint modified CTOD failure assessment diagram - Université de Lorraine Access content directly
Journal Articles Structural Integrity and Life Year : 2018

Assessment of PIPE for CO 2 transportation using a constraint modified CTOD failure assessment diagram

Abstract

Failure Assessment Diagram (FAD) is constraint modified using the assumption that the constraint T stress is proportional to the non-dimensional loading. The constraint modified FAD has been used to compute safety factors associated elliptic defects.
No file

Dates and versions

hal-03172664 , version 1 (17-03-2021)

Identifiers

  • HAL Id : hal-03172664 , version 1

Cite

Mohamed-Raouf Amara, O Bouledroua, M. Hadj Meliani, B.G.N. G N Muthanna, M. Tahar Abbess, et al.. Assessment of PIPE for CO 2 transportation using a constraint modified CTOD failure assessment diagram. Structural Integrity and Life, 2018, 18 (2), pp.149-153. ⟨hal-03172664⟩
92 View