Six-Leg AC-AC Fault Tolerant Converter with Reduced Extra-Sensor Number - Archive ouverte HAL Access content directly
Journal Articles International Review of Electrical Engineering Year : 2011

Six-Leg AC-AC Fault Tolerant Converter with Reduced Extra-Sensor Number

Abstract

In order to prevent further damage and to provide the continuity of service of six-leg converter in case of open-switch fault, it is mandatory to perform fast fault detection and converter reconfiguration schemes. Extra sensors are needed to detect the faults rapidly. In this paper, a very fast FPGA-based fault detection scheme is presented that minimizes the number of additional voltage sensors. A six-leg fault tolerant converter topology without redundancy and with bidirectional power flow is studied. First simulations are carried out to evaluate the proposed fault detection principle and the fault tolerant converter topology. The fully digital control and the fault detection are implemented on a single FPGA. Experimental tests of the digital controller and the detection scheme are performed to verify the high performance of the proposed method
Fichier principal
Vignette du fichier
Paper_IREE_POURE_ID 4569.pdf (597.02 Ko) Télécharger le fichier

Dates and versions

hal-03568484 , version 1 (13-02-2022)

Identifiers

  • HAL Id : hal-03568484 , version 1

Cite

Mahmoud Shahbazi, Philippe Poure, Mohammadreza Zolghadri, Shahrokh Saadate. Six-Leg AC-AC Fault Tolerant Converter with Reduced Extra-Sensor Number. International Review of Electrical Engineering, 2011, 6 (1), pp.132-138. ⟨hal-03568484⟩